SCA Pharmaceuticals, Inc. Form 483, November 2019
FDA issued this Form 483 to SCA Pharmaceuticals, Inc. in Little Rock, Arkansas (FEI 3010683157) at the end of a drug inspection that ended November 7, 2019. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 7, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 7, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 7, 2020
- 61 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate sterility testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, your method allows for [(o) (4) with the (o) (4) for sterility testing which is not equivalent to USP <71>.
- 2
Failure to review potency failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, on April 5, 2019, you were notified of a confirmed potency failure for Vasopressin 0.4 units/ml in 0.9% NaCl [illegible] bag at the 50-day timepoint for beyond use dating (BUD) by your contract testing laboratory. You assigned a 90-day BUD until May 7, 2019 when you changed the BUD to 50 days. You did not notify your customers of the change in date for (o) ( ) lots of product you distributed prior to changing the BUD due to sub potency results. In addition, your complaint procedure does not specifically include directions when a reserve/retain sample will be tested or visually inspected as part of the complaint investigation as evidenced by CUS 19-020-LR, CUS 19-058-LR, CUS 10-059-LR, CUS 19-060-LR, CUS 19-069-LR, CUS 19-079-LR, and CUS 19-094-LR.
- 3
Insufficient computer/audit controls
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, you have never conducted an audit trail review of the SCANRDI system since you began using it in 2013 for sterility analysis nor do you have a procedure for conducting an audit trail review. Additionally, an employee who performs most of the scanning for the sterility analysis signs in with her Administrator access to perform the scans.
- 4
Missing packaged product documentation
The results of the examination of the packaged and labeled products were not documented in the batch production or control records. Specifically, I observed during the visual inspection by employees rejects from the 100% and the AQL were placed in the same bin, thus not allowing for accurate data to be entered in the batch records to determine if both passed your specification for visual inspection as defined in SOP COM-013-LR. For the AQL, critical defect limit is (b)(4) so if both rejects were counted as part of the 100% inspection, the lot would pass instead of failing.
- 5
Compounding copies of approved drugs
You compound drugs that are essentially a copy of one or more approved drugs within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, you compound drug products that: a) are identical or nearly identical to an approved drug that is not on the drug shortage list in effect under section 506E at the time of compounding, distribution, and dispensing; or b) are not identical or nearly identical to an approved drug but contain a bulk drug substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug.
- 6
Inadequate sterility training/recertification
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, employees responsible for the sterility analysis by Scan RDI are two months late in their [illegible] recertification and continue to process sterility analysis using Scan RDI.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010683157, newest first.
- Form 483, October 2025Inspection ended Oct 30, 2025 · Posted Dec 18, 2025OAI
- Form 483, May 2023Inspection ended May 17, 2023 · Posted Jul 19, 2023VAI
- Form 483, September 2017Inspection ended Sep 29, 2017 · Posted Jan 17, 2024OAI
- Form 483, April 2014Inspection ended Apr 2, 2014 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.