Skip to content

Medlmmune UK Limited (AstraZeneca/Supply Biologics) Form 483, June 2022

FDA issued this Form 483 to Medlmmune UK Limited (AstraZeneca/Supply Biologics) in Liverpool, United Kingdom (FEI 3004066112) at the end of a biologics inspection that ended June 14, 2022. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 30, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 14, 2022
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 30, 2026
1,599 days after the inspection
Facility
FEI 3004066112
Liverpool, United Kingdom

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Critical reagents not qualified before use

    Critical reagents are not always qualified prior to release for use in the manufacturing of U.S. licensed product. SOP-0069233, entitled "General Procedure for Processing and Qualifying Critical Reagents", v13.0 is not always followed. Specifically, [illegible] are critical reagents designed by the [illegible] are not qualified prior to use in the [illegible] to determine if [illegible] However, critical [illegible] (b)(4) the genotypic and phenotypic properties of the (b)(4) the [illegible]

  2. 2

    Deficient bacterial endotoxin detection procedure

    The bacterial endotoxin procedure is deficient to ensure adequate detection of endotoxin in the samples. A. Analytical method used to detect bacterial endotoxin in LAIV Monovalent Bulk (MVB), and LAIV Finished Product are inadequate. Specifically, SOP-0067568, entitled "The Endotoxin Testing of Product by [illegible]", v40.0 is deficient in that the mixing and subsequent preparations are not described. Without sample requirement for the qualified mixing, your firm lacks assurance that endotoxin can be adequately recovered and detected when present in the samples. [illegible] and MVB samples. Endotoxin can adhere to [illegible] are being used to store [illegible] B. (b)(4) to give false negative test results. Your firm conducted a study in 2016 to show [illegible] suitability in recovering endotoxin spike at 5 EU/mL. However, this study was deficient, it did not, for example, demonstrate spike recovery at a lower endotoxin level of [illegible] for [illegible] which is the action limit for MVB.

  3. 3

    Failure to notify license holder of deviation

    Your firm did not notify the license holder of a deviation that may potentially affect the quality of a distributed drug product. Specifically, [illegible] is used in the QC in-process and release of Live Attenuated Influenza (b)(4) The (b)(4) Vaccine (LAIV) drug substance or drug product tests. On 1/17/2019, during the [illegible] of the [illegible] the following failure modes were identified: for the [illegible] - Audit trail did not record the opening of a file for data review. This resulted in no electronic records of reviewer reviewing original data. - Audit trail did not record a [illegible] being read if file was not saved by the analyst. The investigation concluded that there no risk to patients and that there were no product quality concerns. However, the firm did not notify the license holder for them to assess the potentially impacted distributed licensed products in the event of the license holder opting to submit a Biological Product Deviation Report.

  4. 4

    Lack of validation for expiry and sterility

    There is a lack of validation to support [illegible] used within the manufacturing and QC areas. [illegible] assigned expiry. Specifically, (b)(4) (b)(4) is currently applied to a [illegible] You did not [illegible] In 2017, your firm used data provide by the vendor to support the [illegible] conduct your own validation to support the assigned expiry. For example, you did not demonstrate [illegible] while being used by your personnel following your manufacturing procedure within your facilities, can remain sterile at expiry. the (b)(4)

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3004066112, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.