Lupin Limited Unit III Form 483, October 2018

FDA issued this Form 483 to Lupin Limited Unit III in Pithampur, India (FEI 3009107538) at the end of a drug inspection that ended October 18, 2018. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 5, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Oct 18, 2018
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 5, 2018
18 days after the inspection
Facility
FEI 3009107538
Pithampur, India

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate process qualification

    Control procedures are not established which monitor the output and validate the performance of manufacturing processes that may be responsible for causing variability in the characteristics of process material and the drug product. Specifically, a) your process performance qualification (PPQ) study is deficient in that you did not include the (b)(4) l i(b)l4) second exhibit batch for [illegible] which failed [illegible] and you did not include it in your PPQ report. During the inspection, you stated this batch was a product development batch manufactured before exhibit batches and production process is recorded in production records and copies of the PD notebooks. When I asked for the PD notebooks, you stated that this batch was the first [illegible]. Review of your SAP records showed that this batch was the second exhibit batch which [illegible]. You rejected the batch.

  2. 2

    Insufficient cleaning procedures

    Written procedures for cleaning and maintenance fail to include description of methods, equipment and materials used, description of disassembling and reassembling equipment as necessary to assure removal or obliteration of previous batch identification. Specifically, a) cleaning validation and verification [b)(4) / (b)(4)] did not include or did not perform full cleaning studies [illegible]; production room [illegible]; such as solutions, contamination and carryover. You failed to provide a proper study. During the inspection you stated [b)(4)] [b)(4)] and stated you perform Type 1 [b)(4)] cleaning. You provided a series of data on Oct. 16, 2018 (two days before inspection close). b) [illegible] swab sample results for different products [b)(4)] and stated you have done a few studies [illegible]. c) your batch record for [illegible] cleaning and cleaning instructions on [b)(4)] room for the operator to access.

  3. 3

    Inadequate computerized system controls

    Appropriate controls are not exercised over computerized systems, master production and control records or other records. Specifically, a) control over the computerized system in [illegible] permits modification to the sequences in HPLC and GC. The reviewer does not review the modification to the sequence. Your QC reviewer even stated that they do not investigate modifications to the sequence during normal review and accepts the audit trail entry "sequence modified." You stated that the unlocking permissions should be approved by QA and are kept in modified folders for that specific sequence. You failed to provide a copy of a folder for a modified sequence which is approved by QA. When I asked for traceability of the permission records you stated the permission records are not traceable. b) your procedures (QCD-60, QCD-61, and ITP-034) for control instruction modification do not provide adequate control over standalone instruments such as FTIR, UV and creation/locking of folders for sequences.

  4. 4

    Deficient sampling procedures

    Sampling procedures are deficient regarding sample collection and container. Specifically, your sampling practice for removal/collection is deficient in that you do not collect samples from different locations of material containers (top, middle and bottom). You use sampling or collect samples [redacted] and [illegible], and you have not adequately established sampling of APIs from different size containers, bags packed in a boxes, etc.

  5. 5

    Incoming product acceptance lacking tests

    Procedures for acceptance of incoming product are deficient. Specifically, your procedure for receiving and inspection does not perform functional test on the received device before release of the device for use.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3009107538, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.