Skip to content

Lupin Limited Unit-3

Plot No M - 1, Unit - 3; Apparel Park; And M - 3 - A, Pithampur, India

FEI 3009107538DUNS 650595213

Company: LUPIN LIMITED · Linked by exact D-U-N-S match (675923163) in FDA registration data

FDA has 3 inspections on file for Lupin Limited Unit-3 in Pithampur, India (FEI 3009107538), from 2015 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and packing, through Dec 31, 2027. Its registrant, LUPIN LIMITED (D-U-N-S 675923163), has registered 10 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2015–2025
0 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
2 of 3
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
3 requests, latest Oct 2, 2025
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written in-process control procedures

      Written procedures are not established that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.

    2. Testing Each Component for Conformity with Specs

      Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate process qualification

      Control procedures are not established which monitor the output and validate the performance of manufacturing processes that may be responsible for causing variability in the characteristics of process material and the drug product. Specifically, a) your process performance qualification (PPQ) study is deficient in that you did not include the (b)(4) l i(b)l4) second exhibit batch for [illegible] which failed [illegible] and you did not include it in your PPQ report. During the inspection, you stated this batch was a product development batch manufactured before exhibit batches and production process is recorded in production records and copies of the PD notebooks. When I asked for the PD notebooks, you stated that this batch was the first [illegible]. Review of your SAP records showed that this batch was the second exhibit batch which [illegible]. You rejected the batch.

    2. Observation 2

      Insufficient cleaning procedures

      Written procedures for cleaning and maintenance fail to include description of methods, equipment and materials used, description of disassembling and reassembling equipment as necessary to assure removal or obliteration of previous batch identification. Specifically, a) cleaning validation and verification [b)(4) / (b)(4)] did not include or did not perform full cleaning studies [illegible]; production room [illegible]; such as solutions, contamination and carryover. You failed to provide a proper study. During the inspection you stated [b)(4)] [b)(4)] and stated you perform Type 1 [b)(4)] cleaning. You provided a series of data on Oct. 16, 2018 (two days before inspection close). b) [illegible] swab sample results for different products [b)(4)] and stated you have done a few studies [illegible]. c) your batch record for [illegible] cleaning and cleaning instructions on [b)(4)] room for the operator to access.

    Show observations 3 to 5
    1. Observation 3

      Inadequate computerized system controls

      Appropriate controls are not exercised over computerized systems, master production and control records or other records. Specifically, a) control over the computerized system in [illegible] permits modification to the sequences in HPLC and GC. The reviewer does not review the modification to the sequence. Your QC reviewer even stated that they do not investigate modifications to the sequence during normal review and accepts the audit trail entry "sequence modified." You stated that the unlocking permissions should be approved by QA and are kept in modified folders for that specific sequence. You failed to provide a copy of a folder for a modified sequence which is approved by QA. When I asked for traceability of the permission records you stated the permission records are not traceable. b) your procedures (QCD-60, QCD-61, and ITP-034) for control instruction modification do not provide adequate control over standalone instruments such as FTIR, UV and creation/locking of folders for sequences.

    2. Observation 4

      Deficient sampling procedures

      Sampling procedures are deficient regarding sample collection and container. Specifically, your sampling practice for removal/collection is deficient in that you do not collect samples from different locations of material containers (top, middle and bottom). You use sampling or collect samples [redacted] and [illegible], and you have not adequately established sampling of APIs from different size containers, bags packed in a boxes, etc.

    3. Observation 5

      Incoming product acceptance lacking tests

      Procedures for acceptance of incoming product are deficient. Specifically, your procedure for receiving and inspection does not perform functional test on the received device before release of the device for use.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Oct 2, 2025. Each one asked for a Form 483.

  • Inspection ending Jul 17, 2025VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Oct 2, 2025FDA-FOIA-2025-11559Form 483Records released
    2. Jul 18, 2025FDA-FOIA-2025-8800Form 483· 1 of 2 sitesRecords released
  • Inspection date not given

    1 request.

    1. Oct 25, 2018FDA-FOIA-2018-8724Form 483Open

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.

  • 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
  • 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
  • 21 CFR 211.192Production record review1 of 1

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3009107538, one row per refused product line.

1 refusal on 2026-08-13 · charged NOT LISTED on 1 · no FDA sample analysis

FDA firm profile
  • 2026-08-13

    HEMATINIC N.E.C.64NDN99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of West Coast Imports1FX-3343967-0/10002/2

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing
Registration runs through
Dec 31, 2027
Registrant
LUPIN LIMITEDD-U-N-S 675923163

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names LUPIN LIMITED (D-U-N-S 675923163) as the registrant for this site and the 10 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • LUPIN LIMITEDMandideep, India · FEI 30028075116 inspections6latestNov 23, 2022OAI2 warning letters, latest Sep 10, 2019
  • LUPIN LIMITEDVerna, India · FEI 30048198209 inspections9latestNov 21, 2025VAI1 warning letter, Nov 6, 2017
  • LUPIN LIMITEDPithampur, India · FEI 30075496296 inspections6latestJul 17, 2025OAI1 warning letter, Nov 6, 2017
  • LUPIN LIMITEDTarapur, Thane, India · FEI 30028075125 inspections5latestApr 4, 2022OAI1 warning letter, Sep 27, 2022
  • LUPIN LIMITEDNagpur, India · FEI 30153920602 inspections2latestSep 16, 2025VAINone on file
  • LUPIN LIMITEDPithampur, India · FEI 30098317994 inspections4latestSep 27, 2024VAINone on file
  • LUPIN LIMITEDAurangabad, India · FEI 30049956455 inspections5latestMar 15, 2024VAINone on file
  • LUPIN LIMITEDMandideep, India · FEI 30077564733 inspections3latestAug 11, 2023NAINone on file
  • LUPIN LIMITEDNagpur, India · FEI 30098432074 inspections4latestJul 11, 2023VAINone on file
  • LUPIN LIMITEDGujarat, India · FEI 3002807510Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3009107538 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3009107538. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.