Lupin Limited Unit 2
Unit-2, Plot No. M-2 and M-2-A, Special Economic Zone Phase II, Misc. Zone, Apparel Park, Dist. Dhar, Pithampur, India
FEI 3007549629DUNS 863645527
Company: LUPIN LIMITED · Linked by exact D-U-N-S match (675923163) in FDA registration data
FDA has 6 inspections on file for Lupin Limited Unit 2 in Pithampur, India (FEI 3007549629), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). 4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and packing, through Dec 31, 2027. Its registrant, LUPIN LIMITED (D-U-N-S 675923163), has registered 10 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2009–2025
- 4 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 6
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 3 requests, latest Jul 18, 2025
- Warning letters
- · CDER ↗
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Written in-process control procedures
Written procedures are not established and followed that describe the examinations to be conducted on appropriate samples of in-process materials of each batch.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up.
Following/documenting laboratory controls
Established laboratory control mechanisms are not documented at the time of performance.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Show 1 more citation
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Invalidation of OOS results
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your firm has invalidated approximately 96% of all the Out-of-Specification (OOS) results obtained during the testing of commercial drug products during the last two years as summarized below: Type of Sample Total # of OOS | # of invalidated | % invalidated Obtained in 2015 & 2016 | OOS in 2015 & 2016 | OOS in 2016 Commercial stability Samples 33 32 97. Finished product Samples 62 61 ee Among the invalidated OOS results more than 75% of them were attributed to human error which raises concerns about the ability of your laboratory personnel to properly conduct the required analytical testing. For example, a) OOS investigation, OOS/C/16/IN2/SS/005 was initiated on 11-May-2016 to find the 18-month long-term stability assay failure for “Tablets, USP” mg. A failing assay result of (b)(4) was obtained against a specification limit of (b)(4) to (b)(4) % of label claim. Your firm invalidated the failing result through re-testing and attributing the failed result to solution preparation error. Your firm has attributed similar solution preparation errors to OOS results 26 times during the last two years and OOS results were invalidated. b) OOS investigation, OOS/C/16/IN2/FP/011 was initiated on 22-April-2016 to find the assay failure for the finished product “Tablets, USP” | mg (Batch# (b)(4)). Failing assay results of (b)(4) and (b)(4) respectively were obtained against a specification limit of (b)(4) to (b)(4) % of label claim. Your firm invalidated the failing result through re-testing and attributed it to dilution error during sample preparation. Your firm has attributed similar dilution error to OOS results 19 times during the last two years and OOS results were invalidated. c) OOS investigation, OOS/C/15/IN2/SS/007 was initiated on 08-April-2015 to find the 30-month stability assay failure for (b)(4) and (b)(4) Tablets, USP 2 mg. A failing assay result of (b)(4) was obtained against a specification limit of (b)(4) to (b)(4) % of label claim for (b)(4). Your firm invalidated the failing result through re-testing and attributed it to error during sample preparation. Your firm has attributed similar error to OOS results 9 times during the last two years and OOS results were invalidated. d) OOS investigation, OOS/C/15/IN2/SS/002 was initiated on 21-February-2015 to find the 18-month stability dissolution failure for (b)(4) Tablets, USP (b)(4) mg. A failing dissolution result of 5% was obtained in 15 minutes against a specification limit of NLT (b)(4). Your firm invalidated the failing result through re-testing and attributed to vial filling error during sample preparation. Your firm has attributed sample preparation error to OOS results 8 times during the last two years and OOS results invalidated. e) OOS investigation, OOS/C/15/IN2/FP/019 was initiated on 19-June-2015 to find the finished product assay failure for (b)(4) Tablets, USP (b)(4) mg. A failing assay result of (b)(4) was obtained against a specification limit of (b)(4) % to (b)(4) % of label claim. Your firm invalidated the failing result through HPLC peak re-integration and attributed to contamination error. Your firm has attributed similar contamination error to OOS results 9 times during the last two years and OOS results were invalidated. You have failed to take timely corrective actions to prevent repeated human errors and attributed these errors to invalidate out of specification results.
- Observation 2
Incomplete investigation conclusions
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up. Specifically, your firm conducted an investigation into why the (b)(4) materials going through the manufacturing process of (b)(4) and (b)(4) Tablets USP (Batch# (b)(4) and (b)(4)) were kept in quarantine area for more than (b)(4). The root cause in the delay in performing the remaining steps of the manufacturing processes was attributed to human error in failing to track the subsequent process steps such as (b)(4) activity. However, during the interview, your firm's Site Head stated that if there are not sufficient orders or demands for a specific product are low, it may take a longer period of time for the in-process material to be taken to the next step. The statement provided by the Site Head contradicts the conclusion drawn during the investigation. Root causes identified in the investigation do not represent the actual reason for the delay in this case.
Show observations 3 to 6
- Observation 3
Inadequate hold time studies
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, your hold time studies do not represent those of commercial batches and the quantity used for these studies are not justified. Hold time studies of products intended for the US market were performed as per protocol titled, “Hold Time Study Protocol for Compressed or Tablets as Finished Product” (# HT2/004-00). According to protocol HT2/004-00 and other hold time study protocols, irrespective of the batch size, only (b)(4) of the representative sample was placed in a simulated container. For example, the following is a summary of selected samples for the hold time study: Product Strength Batch Size | Quantity used for Hold Time Study (b)(4) Tablets USP (b)(4) (b)(4) (b)(4) (b)(4) Tablets USP (b)(4) (b)(4) (b)(4) (b)(4) Tablets USP (b)(4) (b)(4) (b)(4)
- Observation 4
Missing personnel identification/verification
The batch production and control records are deficient in that they do not include identification of persons performing, supervising and checking each significant step in the operation. Specifically, there was no identification of the person entering the values from critical process steps in the batch manufacturing records and there was a lack of second person verification of each step. For example, - Number of bottles went into incubation in each were entered into the batch manufacturing record (Batch# (b)(4)) without anyone signing the page during the aseptic process simulation (Media Fill). - Visual inspection of incubated bottles for the microbial contamination results were entered into the batch manufacturing records by the analysts without anyone checking or verifying.
- Observation 5
Insufficient stability chamber qualification
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the qualification of your firm’s stability chambers lacks data to fully support the temperature uniformity throughout the chambers. The temperature mapping of your firm's stability chambers is based on fixed temperature & humidity probes within the stability chambers. According to the mapping diagrams each stability chamber has a total of (b)(4) temperature & humidity probes which have been permanently installed on the panels of the chambers. Each of the probes has data loggers which record temperature and humidity data at its location. As an example, for stability chamber SC-11, which is kept at 25+2 °C/60+5% RH and has a capacity of (b)(4) L, the firm could only provide temperature and humidity data for each of the fixed probes. This stability chamber is used for long-term stability studies for US products. The firm has not provided temperature & humidity data to show that the temperature and humidity in the center of their stability chambers meets the specified conditions.
- Observation 6
No verification of backup storage tank
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, your firm does not have a procedure in place to verify if the back-up (b)(4) for the Storage Tank (T-602-1) will work. According to SOP EN2-079-03 section 5.4.18 "Operation of (b)(4) Unit and Distribution Loop," your firm’s engineering personnel are to "ensure that tank (b)(4) should be maintained NLT by (b)(4)." (b)(4) is the back-up (b)(4) for the firm’s storage tank (T-602-1) in the event that there is an interruption to the supply. Your firm does not regularly verify that the back-up (b)(4) works as intended. This back-up is used for the regular manufacturing of sterile products such as (b)(4) Solution, (b)(4) % and (b)(4) Solution, (b)(4) %.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 18, 2025. Each one asked for a Form 483.
Inspection ending Jul 17, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 18, 2025FDA-FOIA-2025-8800Form 483· 1 of 2 sitesRecords released
Inspection date not given
2 requests.
- Nov 12, 2020FDA-FOIA-2020-8051Form 483· 1 of 2 sitesClosed
- Feb 5, 2019FDA-FOIA-2019-836Form 483Open
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.160General requirements1 of 2
Show all 9
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007549629, one row per refused product line.
4 refusals from 2019-03-13 to 2019-04-12 · charged UNAPPROVED on 4 · no FDA sample analysis
FDA firm profile- 2019-04-12
PYRAZINAMIDE (ANTI-BACTERIAL)61HCA27
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4130423-0/11/1
- 2019-03-13
BUDESONIDE (ANTI-ASTHMATIC)61EDQ04
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports9ES-0044824-9/31/1
- 2019-03-13
BUDESONIDE (ANTI-ASTHMATIC)61EDQ04
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports9ES-0044824-9/21/1
- 2019-03-13
BUDESONIDE (ANTI-ASTHMATIC)61EDQ04
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports9ES-0044824-9/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing
- Registration runs through
- Dec 31, 2027
- Registrant
- LUPIN LIMITEDD-U-N-S 675923163
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names LUPIN LIMITED (D-U-N-S 675923163) as the registrant for this site and the 10 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- LUPIN LIMITEDMandideep, India · FEI 30028075116 inspections6latestNov 23, 2022OAI2 warning letters, latest Sep 10, 2019
- LUPIN LIMITEDVerna, India · FEI 30048198209 inspections9latestNov 21, 2025VAI1 warning letter, Nov 6, 2017
- LUPIN LIMITEDTarapur, Thane, India · FEI 30028075125 inspections5latestApr 4, 2022OAI1 warning letter, Sep 27, 2022
- LUPIN LIMITEDNagpur, India · FEI 30153920602 inspections2latestSep 16, 2025VAINone on file
- LUPIN LIMITEDPithampur, India · FEI 30091075383 inspections3latestJul 17, 2025VAINone on file
- LUPIN LIMITEDPithampur, India · FEI 30098317994 inspections4latestSep 27, 2024VAINone on file
- LUPIN LIMITEDAurangabad, India · FEI 30049956455 inspections5latestMar 15, 2024VAINone on file
- LUPIN LIMITEDMandideep, India · FEI 30077564733 inspections3latestAug 11, 2023NAINone on file
- LUPIN LIMITEDNagpur, India · FEI 30098432074 inspections4latestJul 11, 2023VAINone on file
- LUPIN LIMITEDGujarat, India · FEI 3002807510Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3007549629 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3007549629. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.