Supplier controls and component testing in FDA Form 483 observations
Qualifying suppliers and contract labs, testing incoming components, and relying on a supplier's certificate of analysis. FDAgent finds 128 such observations in 89 Form 483s issued to 86 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 128
- Each quoted below
- Form 483s
- 89
- Posted by FDA
- Facilities
- 86
- Distinct FEIs
- Most recent
- Sep 9, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 48 in 2026
| Year | Observations |
|---|---|
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 2 |
| 2015 | 3 |
| 2016 | 8 |
| 2017 | 1 |
| 2018 | 3 |
| 2019 | 7 |
| 2020 | 1 |
| 2021 | 4 |
| 2022 | 7 |
| 2023 | 14 |
| 2024 | 3 |
| 2025 | 23 |
| 2026 | 48 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the supplier controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“supplier*” · “vendor qualif*” · “vendor audit*” · “vendor approv*” · “approved vendor*” · “certificate* of analys*” · “CoA*” · “COA*” · “purchasing control*” · “contract manufactur*” · “contract laborator*” · “contract test*” · “identity test*” · “component* … not … tested”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 128 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
NCFMC, a Medical CorporationInspection ended Aug 19, 2025 · FEI 3003971346 · Observation 2
… According to the instructions provided by the contract testing laboratory, female patients should not (b) (4) the (b) (4) providing their specimen for testing.
Contains “contract test*”Read the Form 483 →
Tripak Pharmaceuticals Pty Ltd.Inspection ended Jul 25, 2025 · FEI 3008549263 · Observation 1
… an OOS investigation #122 for one of the inactive ingredients used in the manufacturing of (b) (4) mL), Lot #(b) (4) (Bulk Lot #(b) (4) Exp (b) (4) Your contract testing laboratory reported twice for failed (b) (4) content in (b) (4), Batch (b) (4) Your firm proceeded with manufacturing of finished product Lot #(b) (4) using the failed inactive ingredient. This product was later released to your customer and subsequently shipped to the US market. …
Contains “contract test*”Read the Form 483 →
Tripak Pharmaceuticals Pty Ltd.Inspection ended Jul 25, 2025 · FEI 3008549263 · Observation 2
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, a) Your firm failed to conduct identification tests for raw materials used in drug product manufacturing. Specifically, your firm failed to verify the identity of each component prior to use in manufacturing operations. For example, your firm used (b) (4) (b) (4) Lot (b) (4) in the manufacture of (b) (4) …
Opens with FDA's citation wording for 21 CFR 211.84(d)(2)Read the Form 483 →
Veganic SKN LimitedInspection ended Jul 21, 2025 · FEI 3024609429 · Observation 2
… Your contract testing laboratory me who is responsible for testing the finished wa products, reported an OOS result for Cn on 08/28/2024. The reported result was m@ for a specification of "we " w® opened an investigation # OOS No: 276B on 08/28/2024, and Phase II of the investigation was initiated on 12/04/2024; however, the investigation was not completed until 07/11/2025. Your firm released this lot on gw and shipped it to the US market on ge …
Contains “contract test*”Read the Form 483 →
Veganic SKN LimitedInspection ended Jul 21, 2025 · FEI 3024609429 · Observation 4
OBSERVATION 4 Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, From 06/02/2024 to 05/05/2025 your firm released w@ lots of me products to the US market. These lots were manufactured usingg as an inactive ingredient. At the time of manufacturing, you accepted thew @ based on the supplier's Certificate of Analysis (COA) and failed to conduct specific …
Opens with FDA's citation wording for 21 CFR 211.84(d)(2)Read the Form 483 →
Foremount Enterprise Co., LtdInspection ended Jun 19, 2025 · FEI 3010402691 · Observation 4
… Your firm is a Manufacturer and Contract Manufacturer of various medical devices to include Class II Non-Rebreathing Valves, Product Code CBP exported and intended for the US market. Your firm conducts Ultrasonic Welding on machines (b) (4) in the manufacturing for your Class II Non-Rebreathing Valves, Product Code CBP exported and intended for the US market; however, your firm was not able to provide protocols and objective evidence to support …
Contains “contract manufactur*”Read the Form 483 →
Foremount Enterprise Co., LtdInspection ended Jun 19, 2025 · FEI 3010402691 · Observation 9
Personnel do not have the necessary training and experience to perform their jobs. Specifically, throughout the inspection key members of your firm who participated and provided relevant information were not familiar with the USFDA regulations and requirements for Manufacturers and Contract Manufacturers exporting medical devices intended for the US market to include: a) 21 CFR Part 803 - Medical Device Reporting b) 21 CFR Part 807 - …
Contains “contract manufactur*”Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 5
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, you have not certified that water is sterile and nonpyrogenic whereby it is accompanied by a valid COA to ensure the reliability of …
Opens with FDA's citation wording for 21 CFR 211.84(d)(2)Read the Form 483 →
AVEM Labs LLCInspection ended May 21, 2025 · FEI 3017596057 · Observation 4
Documentation of the receipt of supplies was not maintained. Specifically, you did not maintain records of receipt that includes the date of receipt, quantity obtained, and quality release for use of your (b) (4) part ID: (b) (4) and (b) (4) part ID: (b) (4) that were manufactured by your supplier on 03/19/2019 and are currently being used as primary packaging for your BioVair DL (b) (4) and (b) (4) amniotic membrane (b) (4).
Contains “supplier*”Read the Form 483 →
Guangxi Yulin Pharmaceutical Group Co. Ltd.Inspection ended Mar 21, 2025 · FEI 1000589993 · Observation 3
… Microbiological and identity testing is only performed at the beginning of your stability study at the end of your study at (b) (4) You do not have scientific rational to support this test frequency. (C) Stability testing for (b) (4) does not testing for the active contents and you do not have scientific rational to justify not performing this test.
Contains “identity test*”Read the Form 483 →
Guangxi Yulin Pharmaceutical Group Co. Ltd.Inspection ended Mar 21, 2025 · FEI 1000589993 · Observation 7
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. Specifically, (A) Your firm failed to maintain records for routine supplier audits of your active pharmaceutical ingredient supplier. Records for the last (b) (4) supplier audits for your (b) (4) active pharmaceutical ingredient supplier could not be found. The last record your …
Contains “supplier*”Read the Form 483 →
Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 5
… HPLC and GC are used to perform identity testing of APIs and a finished product. C) Your firm has not designed and performed cleaning validation studies on equipment used in the manufacture of US drug products including for (b) (4) D) You do not follow your procedure for "(b) (4) operating Regulations" CZ-21-4114 for testing of (b) (4) The procedure requires (b) (4) testing of (b) (4) including for microorganisms. Your last (b) (4) testing was …
Contains “identity test*”Read the Form 483 →
Qingdao Kangyuan Pharmaceutical Co., LTDInspection ended Aug 16, 2024 · FEI 3006512854 · Observation 3
Failure to validate and verify the suitability of analytical methods. Specifically, (b)(4) Your firm is using the Chinese Pharmacopeia for identity testing of a raw material used in the production of (b)(4). [illegible] Chinese Pharmacopeia identity test method for (b)(4) is equivalent to, or better than, the U.S. Pharmacopeia (USP) identity test method for the same substance.
Contains “identity test*”Read the Form 483 →
Nubratori, IncInspection ended Jul 26, 2024 · FEI 3010166491 · Observation 6
Establishment of the reliability of the component supplier's report results are not appropriately validated at appropriate intervals. Specifically, Your firm failed to conduct full testing as part of the Bulk Drug Substance supplier qualification. Your firm's written procedure is inadequate. The firm has not performed full testing of incoming [illegible] applies to the following BDS: Dexamethasone Sodium Phosphate (Lot [illegible]), Lidocaine HCl …
Contains “supplier*”Read the Form 483 →
Titan Kogyo, LtdInspection ended Dec 8, 2023 · FEI 3009155994 · Observation 3
Verification testing of the raw material supplier COA is inadequate as the firm has failed to conduct all of the analyses listed on the respective supplier COA. For example: The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: appearance, specific gravity, (b) (4) (b) (4) The firm's verification testing of the aforementioned supplier COA only included the following: specific gravity, (b) (4) The (b) (4) lot# (b) (4) COA from …
Contains “supplier*”Read the Form 483 →
Alkem Laboratories LimitedInspection ended Dec 1, 2023 · FEI 3008450172 · Observation 3
… in required trainings such as Awareness Training based on Incident M/LI2021/0056, Change Management for software hardware and network, and Handling of Contract Testing Laboratories.
Contains “contract test*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 1
… Examples include POS206.142_R0 Lab Checklist - Data Processing for HPIC Issue Date: 27FEB2023 POS201.27_R0 Issue Checklist for CoA Generation/ Checklist for CoA Review Issue Date: 14JAN2022 c) Annual product quality reviews are not being performed in a timely manner. As of the date of this inspection, your firm has not completed an annual product quality review for products manufactured in 2022. d) The annual product quality review for products …
Contains “CoA*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 5
… In addition, your firm uses (b) (4) starting material) from (b) (4) different suppliers however, your firm has not evaluated the need to place lots made from each supplier on stability. The stability study conducted on (b) (4) lots of (b) (4) API manufactured at your Perth facility in 2015 does not have an approved written protocol. Your firm did not define the tests to be performed at each time point. The spreadsheet indicates all release tests …
Contains “supplier*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 9
… have (b) (4) stability samples for the (b) (4) USP) stored in the long term chamber as well as other samples related to (b) (4) dispersions and (b) (4) being contract tested. Your firm has no temperature or humidity data from October 6, 2022 to present except for a (b) (4) note in a logbook. There are several recent entries noting the temperature and/or humidity was out of specification however, no investigation was initiated.
Contains “contract test*”Read the Form 483 →
Jiangsu Intco Medical Products Co., LtdInspection ended Nov 17, 2023 · FEI 3005260401 · Observation 3
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed. Specifically, Drug components used in the manufacture of [illegible] lack identification testing. For example, your firm does not perform spectroscopic identification tests and limit of [illegible] or spectroscopic identification tests and limit of [illegible]. Each assessment is described as an identification …
Opens with FDA's citation wording for 21 CFR 211.84(d)(1)Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closuresIn this theme's rule15
- 21 CFR 211.22Responsibilities of quality control unit8
- 21 CFR 211.192Production record review6
- 21 CFR 211.160General requirements5
- 21 CFR 211.100Written procedures; deviations4
- 21 CFR 211.113Control of microbiological contamination3
- 21 CFR 211.166Stability testing3
- 21 CFR 211.194Laboratory records3
- 21 CFR 820.75Process validation2
- 21 CFR 1.512What FSVP may I have if I am a very small importer or I am importing certain food from certain small foreign suppliers?1
Ask FDAgent about supplier controls in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.