Alkem Laboratories Limited Form 483, December 2023
FDA issued this Form 483 to Alkem Laboratories Limited in Ankleshwar, India (FEI 3008450172) at the end of a drug inspection that ended December 1, 2023. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Dec 1, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 17, 2026
- 1,082 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unvalidated analytical methods for alternative testing
Validated methods have not been established for testing of API's. Specifically, your firm does not have a validated method for (b) (4) API's to which the site is used as an alternative testing facility. The site is documented to test for identification of (b) (4) API's by (IR) and water content by (KF). However, during the inspection, when reviewing the method validation and verification documentations, no method verification / validation is established for IR with equipment # MIR1601 and Karl Fisher with equipment # MKF1603, and for (b) (4) (b) (4) API's. According to Sr. General Manager - Quality both methods will be established after (b) (4)
- 2
Inadequate investigations for fire and excursions
Investigations are inadequate in that they do not evaluate all potential root causes of unexpected results nor are they adequately extended to potentially impacted API. Specifically, A- On December 10, 2022, a fire ensued in Plant-(b) (4) The fire caused damage to all of the technical area of Plant-(b) (4) Your firm investigated the incident through Deviation M/DEV/2022/0031 with closing date of April 20, 2023. In reviewing the deviation, your firm failed to document the final status of approximately (b) (4) of the (b) (4) raw materials that are affected during the fire. The raw materials are listed on Activity PR#103249. That document states (b) (4) raw materials are "Available", "(b) (4) material kept in Finished goods storage area (b) (4) ", "Not found", or "In process (b) (4) ". Examples of some of the raw materials listed are: (b) (4) The report also does not state if the materials are used or disposed. In addition, the document states approximately (b) (4) other raw materials are used. B- Excursions for Stability Chamber / Cooling Chamber / Deep Freezer are documented on M-QC/0173-F0002-000 under Standard Operating Procedure, M-QC/0173-004, documented titled, 'Operation and Monitoring of Stability Chamber, Cooling Chamber and Deep Freezer (Make: Newtronic) through ICDAS v2.1 Software', with effective date June 1, 2022. On November 29, 2023, I observed 2 excursion reports that are not fully documented. 1- Report for stability chamber MDF1601 with storage condition -20 degrees C +/- 5 degrees, with approve date October 4, 2022. The report states that ice had formed on the coils and the coils needed to be defrosted with hot water. While interviewing Senior Executive Quality Control of the excursion, are the stability samples moved from the chamber MDF1601 during the defrosting of the chamber. He stated that all the samples from chamber MDF1601 are moved to a different chamber but that activity is not documented. 2- Report for stability chamber MDF1603 with storage condition 25 degrees C +/- 2, 60% +/- 5%RH degrees, with approve date November 7, 2022. The report states that the humidity is below the set limit for approximately 14 hours. The excursion is corrected by supplying water to the chamber. Senior Executive Quality Control stated that this was corrected by calling the Utility Department to turn on the supply. However, he did not document the activity.
- 3
Employees lack required training for assigned functions
Employees engaged in the manufacture, processing, packing, holding of finished API's lack the training required to perform their assigned functions. You cannot assure that personnel are adequately trained in order to perform to their assigned duties. Specifically, on December 1, 2023, I reviewed approximately (b) (4) personnel training records through your e-TMS (electronic Training Management System) which included training records from quality management, manufacturing, and contract personnel. I observed employee #(b) (6) is deficient in required trainings such as Awareness Training based on Incident M/LI2021/0056, Change Management for software hardware and network, and Handling of Contract Testing Laboratories.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.