Veganic SKN Limited
243 Milton Road, Milton, Australia
FEI 3024609429DUNS 743536682
FDA has one inspection on file for Veganic SKN Limited in Milton, Australia (FEI 3024609429). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is VEGANIC SKN LIMITED (D-U-N-S 743536682).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request
- Warning letters
- · CDER ↗
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No written QC unit procedures
OBSERVATION 1 The responsibilities and procedures applicable to the quality control unit are not in writing. Specifically, Your firm has not established written procedures defining the quality control unit's responsibilities and authority. Standard operating procedures describing the quality control unit's role and scope of authority were not available during the inspection. As a result, personnel were unclear about their specific duties and decision-making responsibilities within the quality control function.
- Observation 2
QC lacks approval authority
OBSERVATION 2 The quality control unit lacks the responsibility and authority to approve, reject all drug products. Specifically, a) Manufacturing operations are currently proceeding without qualified Quality Assurance (QA) oversight present during critical process steps. This deficiency includes a lack of real-time review and approval of critical process parameters and deviations by qualified QA personnel. Additionally, there is insufficient QA involvement in batch record review during active production phases. The facility's current practice involves production employees fulfilling QA responsibilities, as confirmed by your Head of QA during our inspection. This arrangement compromises the independence required for effective quality oversight, as production personnel cannot provide the objective review necessary for proper QA functions. From 06/02/2024 to 05/05/2025, your firm released me lots of mea products to the US market. A specific example of this deficiency is observed with Lot# mea which demonstrates inadequate QA oversight throughout critical process steps. Moreover, this lot was released for distribution without receiving final QA approval. As another example, I observed that Lot #ige was released by your production manager on behalf of QA. b) Your firm released Lot #wm@ with an open Out of Specification (OOS) investigation. Your contract testing laboratory me who is responsible for testing the finished wa products, reported an OOS result for Cn on 08/28/2024. The reported result was m@ for a specification of "we " w® opened an investigation # OOS No: 276B on 08/28/2024, and Phase II of the investigation was initiated on 12/04/2024; however, the investigation was not completed until 07/11/2025. Your firm released this lot on gw and shipped it to the US market on ge c) From 06/02/2024 to 05/05/2025 your firm released ge lots of we products to the US market without receiving the test results from your contract testing laboratory, ge For example, Lot # ma was released and shipped to US market by your firm on ®@ however, the Certificate of Analysis was not issued by me until 05/14/2025, more than ge after product release.
Show observations 3 to 6
- Observation 3
Missing required microbiological testing
OBSERVATION 3 Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, drug product closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, From 06/02/2024 to 05/05/2025, your firm released ma lots of me products to the US market without conducting required microbiological testing, including testing for me ®@ All your me products contain we an inactive ingredient in the formulations, which significantly increases the microbiological risk profile and necessitates comprehensive microbiological testing to ensure product safety.
- Observation 4
No identity testing of components
OBSERVATION 4 Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, From 06/02/2024 to 05/05/2025 your firm released w@ lots of me products to the US market. These lots were manufactured usingg as an inactive ingredient. At the time of manufacturing, you accepted thew @ based on the supplier's Certificate of Analysis (COA) and failed to conduct specific identity analysis for each lot, which should include a limit test for me and incorporates testing of samples from all containers of all lots. For example.me Lot # m@ ®® was manufactured using me lot # ma which was accepted based on the supplier's COA.
- Observation 5
Expiration dates not stability-supported
OBSERVATION 5 Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, Your firm currently assigns expiration dates based on the packaging date of me products rather than the compounding date, which fails to account for the actual age of the bulk product and potential degradation during storage. Your firm proposes ame expiry period from packaging. For example, me lot # w& was compounded on ga but not packaged untilye (approximately we later), yet was assigned an expiration date of ®@ effectively giving it nearly me total shelf life from compounding
- Observation 6
No adequate hold time studies
OBSERVATION 6 Appropriate written procedures, designed to prevent objectionable microorganisms in drug products not required to be sterile, shall be established and followed. Specifically, From 06/02/2024 to 05/05/2025 your firm released me lots of ma products to the US market without conducting adequate hold time study. Following are examples of lots released without adequate hold time studies: Manufacturing Date of Batch No Bulk ID Bulk Man. Date ee The Producten em ®©
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site. It asked for a Form 483.
Inspection ending Jul 21, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Date not givenFDA-FOIA-2026-4027Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3024609429, one row per refused product line.
2 refusals from 2026-06-09 to 2026-08-13 · charged DRUG GMPS on 2, NOT LISTED on 1 · no FDA sample analysis
FDA firm profile- 2026-08-13
ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PAJ18
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of West Coast Imports1FX-4311289-5/10002/3
- 2026-06-09
ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBL18
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsMFT-1043019-7/10002/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling
- Registration runs through
- Dec 31, 2027
- Registrant
- VEGANIC SKN LIMITEDD-U-N-S 743536682
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3024609429 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3024609429. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.