NCFMC, a Medical Corporation Form 483, August 2025

FDA issued this Form 483 to NCFMC, a Medical Corporation in Sacramento, California (FEI 3003971346) at the end of a biologics inspection that ended August 19, 2025. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 19, 2025
Biologics · Human Cellular, Tissue, and Gene Therapies
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
433 days after the inspection
Facility
FEI 3003971346
Sacramento, California

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Ineligible sperm donor not disqualified for risk factor

    Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents. Specifically, your firm did not determine ineligible known sperm donor (b) (4), (b) (6), (b) (7)(C) after he reported (b) (6), (b) (7)(C) (b) (6), (b) (7)(C) within the preceding five years. Your firm determined the donor to be eligible on 5/7/2021. Sperm was collected on (b) (6), (b) (7)(C) and transferred to a gestational carrier on (b) (6), (b) (7)(C), (b) (6), (b) (7)(C) and (b) (6), (b) (7)(C).

  2. 2

    Chlamydia gonorrhea testing not per manufacturer instructions

    Testing for communicable disease agents was not performed in accordance with the manufacturer's instructions. Your firm is not following the manufacturer's instructions for testing reproductive tissue donors for evidence of Chlamydia trachomatis and Neisseria gonorrhea. Specifically, 1. Your firm collects (b) (4) of urine rather than the required amount of between 20 mL to 30 mL. According to the manufacturer's instructions, collection of more than 30 mL may result in specimen dilution that may reduce test sensitivity; and 2. Your firm provides female HCT/P donors with (b) (4) (b) (4) with the request for the patient to (b) (4) the (b) (4) collection of the specimen that is sent for use by the laboratory to perform donor testing. According to the instructions provided by the contract testing laboratory, female patients should not (b) (4) the (b) (4) providing their specimen for testing.

  3. 3

    Donor eligibility procedures inadequate and inconsistent

    Procedures were not designed to ensure compliance with the donor eligibility requirements. Your firm's written procedures have not been designed to ensure compliance with donor eligibility requirements. Specifically, 1. Your firm's written procedures do not always establish donor acceptance criteria for donors with identified risk factors. For example, your firm's procedures do not specify the criteria or timeframe for when donors will be acceptable to continue with their donation process after risk factors or conditions relevant to the following diseases or disease agents are identified through screening or testing. This is not an all-inclusive list. a. Syphilis b. Gonorrhea c. Chlamydia d. Neurological diseases e. Vaccinia f. West Nile Virus 2. Your written procedures make statements that donor have to meeting waiting requirements, but the time frames were not established as part of the written procedure. For example, your firm's procedure SOP # 05 called "Informing Donors/Intended Parents with Positive Chlamydia Test *Initial Screening*" states a positive test result for Chlamydia will have a waiting period; however, this waiting period has not been defined. 3. Written procedures were observed to be inconsistent with each other. For example, your firm's procedure SOP # 04 called "Informing Egg Donors/Intended Parents with Positive Communicable Disease Tests" states any donor with a positive communicable disease test will be ineligible; however, there are other written procedures that allow the donation to continue when an unspecified waiting period has lapsed. 4. Written procedures covering the review of all available medical records for clinical evidence of HIV have not been established. For example, there is not a procedure that states if, and how, your firm will review all available relevant medical records for a prior positive or reactive screening test for HIV. 5. Your firm provides egg bank services for your clients which includes the recovery and storage of oocytes for later use by the client. Your firm has not established a procedure that covers the donation of oocytes originally exempted from an eligibility determination. A written procedure covering the donation of male gametes has also not been established.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.