Skip to content

Process validation in FDA Form 483 observations

Showing that a manufacturing process reliably makes product that meets its specifications: process validation, PPQ batches and continued process verification. FDAgent finds 78 such observations in 64 Form 483s issued to 62 facilities, for inspections that ended between January 2013 and July 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
78
Each quoted below
Form 483s
64
Posted by FDA
Facilities
62
Distinct FEIs
Most recent
Jul 17, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 20 in 2026

Process validation observations in Form 483s by inspection year
YearObservations
20131
20140
20150
20162
20175
20186
201911
20200
20212
20225
20237
20245
202514
202620

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.110(a)21 CFR 820.75

The same entries the process validation topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“process validation*” · “process performance qualification” · “PPQ” · “continued process verification” · “validation batch*” · “validation lot*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 78 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 4

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in process material and the drug product. Specifically, For visual inspection of drug products and biological drug products purporting to be sterile, operators are qualified on Kt>) (4I vials; doing so allows operators to inspect [6) (4) I, and t>f …

    Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →

  2. Sumitomo Osaka Cement Co., LtdInspection ended Oct 27, 2023 · FEI 3003943727 · Observation 2

    … OOS investigation OOS23001 was initiated on 1/30/2023 to probe the failure of [illegible] (b)(4) to [illegible] in (process validation batch) against a specification of [illegible] API batch (b)(4). No root cause was identified and the original sample from the lab and fresh sample from the (b)(4) warehouse was reanalyzed and the results met the specification. The original result was invalidated and no CAPA was initiated.

    Contains “process validation*”Read the Form 483 →

  3. Synergy Health Ede BVInspection ended Oct 12, 2023 · FEI 3020976354 · Observation 2

    Procedures for monitoring and control of process parameters for a validated process have not been adequately established. Specifically, the conveyor speed in the Xray treatment area has not been adequately defined. Process monitoring is performed at [illegible] According to the operating technician the system allows speed settings between 0 and 4.5 m/minute. The described working range (undocumented) for the conveyor speed is between [illegible]

    Opens with FDA's citation wording for 21 CFR 820.75(b)Read the Form 483 →

  4. Central Glass Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3002806649 · Observation 5

    Your validation protocols for the execution of revalidation studies do not specify critical process steps. Your process validation studies for (b) (4) do not show the critical process parameters that were going to be studied, review of batch records shows that the validation study did not include variation of parameters within the established ranges. In addition parameters such as the timer used to control the flow in the (b) (4) are not defined …

    Contains “process validation*”Read the Form 483 →

  5. Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 1

    … The OOS result was reported for 2 units out of and 3, Sample Size 1x-3x) sample tested for one of the process validations batches: Batch No. (b) (4) (non-US market) (Set 2 Location (b) (4) result %, Stage (b) (4) against the Specification results. You tested the sample using test procedure, STP No. TP/ (UPLC) for (b) (4) Tablets, Effective date 2/19/2021, in line with your analytical method validation report, AMV/R/16027-A/00, Effective date …

    Contains “process validation*”Read the Form 483 →

  6. Genlbet Biopbarmaceuticals SAInspection ended Jan 31, 2023 · FEI 3011160795 · Observation 1

    … [illegible] executed batch sizes for the process performance qualification a. The (b)(4) do not represent the maximum target batch size of [illegible] as [illegible] per the current approved master batch record, (b)(4). b. There is insufficient data to ensure that the uniformity of the formulated (b)(4) containing (b)(4) [illegible] is maintained throughout the hold time and during the [illegible] within the (b)(4). (b)(4) c. The operating ranges …

    Contains “process performance qualification”Read the Form 483 →

  7. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 3

    … Your General Manager of Quality stated that these batches were part of validation batches and were rejected in 2022. You also do not review (b) (4) uniformity data as part of the APQR. Your procedure SOP_MUM_CQA_010879 (4.0) Annual Product Quality Review of Drug Product (Effective date 3/31/2022) is deficient such that it does not have provision for the review of (b) (4) uniformity data.

    Contains “validation batch*”Read the Form 483 →

  8. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 13

    The validation batch production records #(b) (4) dated 03/07/20, for the (b) (4) API Process Performance Qualification (PPQ) instruct for the (b) (4) process to "Load the (b) (4) material uniformly into the (b) (4) with the help of clean (b) (4) of approx. (b) (4) kg capacity, (b) (4) approx. (b) (4) in each (b) (4)." The General Manager of API Manufacturing confirmed that the (b) (4) (b) (4) mm (d) x (b) (4) mm (h)] does not provide any form of …

    Contains “validation batch*”Read the Form 483 →

  9. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 3

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, Internal defect control limits were not established for the (b)(4) Measurement System (b)(4) inspection process. This was noted during the review of the following batches: Product (b)(4) lot# …

    Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →

  10. Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 4

    … However, there was no Process Performance Qualification data at Serum to harvest the [illegible] for the process. The harvest batch batches, and subsequently these was used to produce [illegible] was used to validate and out of DP lots were released. In addition, [illegible] of the batches (b)(4) process with a the MOI of [illegible]

    Contains “process performance qualification”Read the Form 483 →

  11. Bioiberica, S.A.UInspection ended Feb 4, 2022 · FEI 1000418405 · Observation 2

    Control procedures are not established which monitor the manufacturing processes that may be responsible for [illegible] substance. Critical process parameter established as [illegible] the your firm is not controlled and monitored during the process validation studies. [illegible] the [illegible] validate and approve processing method [illegible] greater than (b)(4) with validated time around [illegible]. No studies have been performed on the …

    Contains “process validation*”Read the Form 483 →

  12. Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 1

    … (b) batch# (b) (4) (a post-PPQ run) was manufactured in the same suite after a campaign of (b) batches of Molecule (b) was manufactured. c. Molecule (b) is classified as a Band C (b) (4) product) for cleaning, per RA-389.01, Revision 01 to Upstream and Downstream Risk Assessment for Facility and Safety Risk Assessment for Band C Molecule (b). However, the same molecule is classified as Cleaning Band D (non-(b) (4) product) based on the List of …

    Contains “PPQ”Read the Form 483 →

  13. Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 2

    (REPEAT OBSERVATION) There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, The process validation for Prednisolone Acetate/Bromfenac (1/0.075) % Sterile Ophthalmic Suspension, product code (b) (4), is deficient. Process Validation lots (b) (4) were manufactured in 2020 according to …

    Contains “process validation*”Read the Form 483 →

  14. Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 4

    Process validation does not always include inclusion and establishment of all process parameters that should be controlled for reproducible operations. For example: a) Validation of (b)(4) and (b)(4) bag sealing processes (used in package sealing of non-sterile bulk drugs) and validation of (b) sealing of packaged and sterilized gowning (used in aseptic operations) and sterilized stoppers (used in package sealing of sterile bulk drugs) are not …

    Contains “process validation*”Read the Form 483 →

  15. GPC Medical LimitedInspection ended Oct 24, 2019 · FEI 3006513362 · Observation 1

    Process Control Procedures that describe any process controls necessary to ensure conformance to the specifications have not been adequately established. For example: The Procedure for [illegible] does not identify the temperature that the process is operated at. The Cleaning process validation was performed at a temperature of [illegible]. During a walk through of the manufacturing facility on Tuesday October 22, I observed the (b)(4) Cleaning …

    Contains “process validation*”Read the Form 483 →

  16. GPC Medical LimitedInspection ended Oct 24, 2019 · FEI 3006513362 · Observation 4

    A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated. Specifically, the process validation for cleaning did not demonstrate that the acceptance was satisfied. The testing after criteria for cleaning only reported a (b)(4) (b)(4) difference to [illegible] and the acceptance criteria established that there would be no "neat" water. Also cleaning validation did not define or describe …

    Contains “process validation*”Read the Form 483 →

  17. Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 5

    … 07419K20L10A, submitted for [illegible] process validation sample did not include a test for the presence of microorganisms. Add. Continuation Page

    Contains “process validation*”Read the Form 483 →

  18. Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 1

    … Note that these lots of (b) (4) USP are validation batches, and the key starting material is (6) 4) ©) where you do not control or monitor the critical (6)() step of (0) (4) at the specified rate of) L/hr during the manufacture of the API intermediate (b) (4). *1021_LABI/INV/10/18/02 - (0) (4) Lot: (B) (4). (Same as above OOS) *1021_LAB1/00S/02/19/09 -(6) (4) USP Lot: (0) 4). Investigation reports OOS for "description" during 60 month long-term …

    Contains “validation batch*”Read the Form 483 →

  19. Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 4

    4. Process validations of API intermediates are not designed and executed in a manner consistent with the original change control proposals, using all equipment specified in the change control. Specifically, you did not adequately perform the process validation for the manufacture of (6) (4) in API) block as described in Change Control: 1024-P-18-00012. You did not perform an appropriate comparative analysis of all proposed manufacturing …

    Contains “process validation*”Read the Form 483 →

  20. Sun Pharmaceutical Industries Ltd.Inspection ended Jun 11, 2019 · FEI 3002809586 · Observation 1

    OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. The Aseptic Process Validation Master Plan was not followed during execution of media fill run [illegible]. Specifically, [illegible] media fill failure on the [illegible] resulted in media fill failure with over [illegible] media batch contamination in the filled, incubated units. An investigation into the media …

    Contains “process validation*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about process validation in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.