Process validation in FDA Form 483 observations
Showing that a manufacturing process reliably makes product that meets its specifications: process validation, PPQ batches and continued process verification. FDAgent finds 78 such observations in 64 Form 483s issued to 62 facilities, for inspections that ended between January 2013 and July 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 78
- Each quoted below
- Form 483s
- 64
- Posted by FDA
- Facilities
- 62
- Distinct FEIs
- Most recent
- Jul 17, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 20 in 2026
| Year | Observations |
|---|---|
| 2013 | 1 |
| 2014 | 0 |
| 2015 | 0 |
| 2016 | 2 |
| 2017 | 5 |
| 2018 | 6 |
| 2019 | 11 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 5 |
| 2023 | 7 |
| 2024 | 5 |
| 2025 | 14 |
| 2026 | 20 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.110(a)21 CFR 820.75
The same entries the process validation topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“process validation*” · “process performance qualification” · “PPQ” · “continued process verification” · “validation batch*” · “validation lot*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 78 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Wanbury LimitedInspection ended Jul 17, 2026 · FEI 3002980818 · Observation 1
Process validation is deficient in that an unexpected amount of raw material than specified in your validated process was needed in order to produce an active pharmaceutical ingredient. Specifically, Deviation 001/23, covering (b)(4) lower levels of (b)(4) was needed to than required by your validated process. A) For (b)(4) batch (b)(4) less than (b)(4) is needed to of (b)(4) However, at step number (b)(4) was needed, for a total of (b)(4) only …
Contains “process validation*”Read the Form 483 →
Auroactive Pharma Private LimitedInspection ended Jun 26, 2026 · FEI 3030708811 · Observation 1
… The API process validation was utilized in manufacturing (b)(4) batch that was shipped to the US market. LIR-25-00042 Batch (b)(4): The average results from both injections met the product specification (b)(4) to (b)(4)%w/w; however, failed to meet variability ratio specification (b)(4) to (b)(4); the original preparation was discarded and a new sample was prepared and injected on the same day without any scientific rationale; The batch was …
Contains “process validation*”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 1
… Process Validation D) You have not performed process validation for any of the sterile drug products you manufacture to demonstrate that the manufacturing processes are in a state of control and capable of consistently producing results with minimal variability between batches. E) You have not adequately validated your hold time process to demonstrate you can effectively store in-process USP grade bulk drug products for the established (b)(4) day …
Contains “process validation*”Read the Form 483 →
Shilpa Medicare LimitedInspection ended May 29, 2026 · FEI 3018694237 · Observation 1
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your Process Validation (PV) for (b) (4) (b) (4) is deficient. You failed to use the (b) (4) system during in-process checks in (b) (4) stage for all strength due to lack of qualification of the …
Contains “process validation*”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 1
… There are no supplier qualification activities performed prior to introducing the precursor (b) (4) into the manufacture of (b) (4) process validation (PV) batches of (b) (4) Injection (Batch #s (b) (4) In addition, the HPLC identity test performed to receive the precursor raw material at central facility is not specific to confirm the identity of precursor that yields as an active ingredient. B. Your firm accepted transfer tubing — a material …
Contains “process validation*”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 3
Your master production and control records did not include a statement of action limits on radiochemical yield. Specifically, A. The manufacturing batch records for (b) (4) Injection do not include action limits on radiochemical yield. For example, Manufacturing batch record for PPQ batch # (b) (4) on page 3 of 26 Section, Final Product Vial Assay and Sterility Inoculations, the radiochemical yield is only recorded, however, there is no statement …
Contains “PPQ”Read the Form 483 →
Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 1
Your firm failed to demonstrate that the manufacturing process remained in a state of control and was capable of consistently producing drug product meeting established quality attributes during process performance qualification (PPQ) for (b)(4) mg/(b)(4) mL presentation. Specifically, your firm manufactured three PPQ batches [illegible] of (b)(4) mg/(b)(4) mL presentation. These batches exhibited increasingly high overall rejection rates at …
Contains “process performance qualification”Read the Form 483 →
Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 2
Your firm failed to adequately investigate the progressively increasing high visible particulate rejection rates identified during 100% visual inspection of the (b)(4) mg/(b)(4) mL PPQ batches. Specifically, to investigate the two (b)(4) mg/(b)(4) mL PPQ DP batches (b)(4) that exhibited visible particulate rejection rates exceeding the predefined visual inspection acceptance criterion of (b)(4)%, (b)(4) units from each batch's rejected unit pool …
Contains “PPQ”Read the Form 483 →
Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 3
Your firm failed to maintain adequate quality oversight over changes to the established acceptance criterion for 100% visual inspection. Specifically, your firm retrospectively revised the visual inspection acceptance criterion to (b)(4)% from (b)(4)% as defined in the (b)(4) mg/(b)(4) mL PPQ protocol (PV-VP-000027), and the revision of visual inspection acceptance criterion was implemented retrospectively without an approved change control. Your …
Contains “PPQ”Read the Form 483 →
USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 4
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, your visual inspection process for sterile products is inadequate: A. Your firm manufactures sterile injectable products including (b) (4) (b) (4) Injection. Review of your visual inspection …
Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 6
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, since February 2024, your firm has manufactured (b) (4) and (b) (4), in house. A comparison study was conducted to demonstrate the comparability between your in-house manufacturing process and the prior contract …
Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →
Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 2
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm's process validation for (b) (4) and (b) (4) does not include scientific data or rationale to support the (b) (4) of ™ to ®@ (8) (4) used during manufacturing of these drug products. …
Contains “process validation*”Read the Form 483 →
Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 2
… Specifically, you initiated Long Term stability studies for the process validation batches after >3 months from the date of manufacturing. Your Quality Head (b)(6) stated that the firm did not have a deviation procedure and shared a form, OTC Deviation Form FDAF012 Version 1 that the firm uses to record deviations. C. You did not follow your FDA Change Control Procedure, FDASOP001 Version 1 such that you did not initiate change control prior to …
Contains “process validation*”Read the Form 483 →
Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 4
… You designed the process validation protocol, PVal014 for (b)(4) batches at (b)(4) from (b)(4) batch size. According to your Process Validation Report, the first batch failed. You added a (b)(4) batch at (b)(4) to complete the process validation. You have manufactured commercial batches that range in (b)(4). Your Production Head (b)(6) stated that the process validation batch size, (b)(4) batch sizes were designed to utilize the minimum and …
Contains “process validation*”Read the Form 483 →
MicroBioPharm Japan Co., LtdInspection ended Feb 13, 2026 · FEI 3003992082 · Observation 3
Your process validations are inadequate. Specifically, You have performed a process validation for the manufacturing of the API (b)(4) (DMF# (b)(4)) using production equipment that have not been qualified. For example, the process verification protocols, (b)(4) have used major production equipment that have not been adequately qualified. (b)(4) The lack of equipment qualification undermines the validity of the process validation study, as there …
Contains “process validation*”Read the Form 483 →
Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 2
There are no written procedures for production and process controls designed to assure that the OTC products have the identity, strength, quality and purity they purport or are represented to possess. A. For example, your firm has not performed the process validation for (b)(4) OTC product. Nevertheless, your firm has been releasing (b)(4) commercial batches (i.e., (b)(4) Exp Date respectively) to be distributed in the USA market. B. Your firm …
Contains “process validation*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 6
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A) No process validation has been performed for OTC drug product (b) (4), USP ((b) (4) Tablet), which is not in accordance with the firm's established written procedure, SOP-25 "Process Validation" …
Contains “process validation*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 2
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm has failed to establish adequate process validation and production control procedures. Your process validation for (b)(4) USP API and key starting materials does not accurately reflect …
Contains “process validation*”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 5
… B) Deviation WATD23E0838 documented OOS activity results of (b) (4) for batch (b) (4) at the (b) (4) Bioburden (b) (4) stage and an OOS result for PPQ batch (b) (4) at the (b) (4) (b) (4) stage. The firm's investigation concluded that sample contamination with (b) (4) during (b) (4) was the probable root cause and determined "no impact to the PPQ program." However, this conclusion was based on a hypothesis of sample contamination with (b) (4) …
Contains “PPQ”Read the Form 483 →
US Specialty Formulations LLCInspection ended Jan 14, 2026 · FEI 3010680515 · Observation 4
… requires visual inspectors to undergo consists only of an eye exam prescription achieve 20/20 vision with correction or meet (D) Your firm has not completed process validation for the filling operation Injection to demonstrate that fill volume accuracy and precision are consistent across batches. Additionally, no production yield specification has been established not defined filling operation loss limits and excludes spill calculations. Your …
Contains “process validation*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.100Written procedures; deviations12
- 21 CFR 211.110Sampling and testing of in-process materials and drug productsIn this theme's rule9
- 21 CFR 211.192Production record review4
- 21 CFR 820.75Process validationIn this theme's rule4
- 21 CFR 211.113Control of microbiological contamination3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2
- 21 CFR 211.22Responsibilities of quality control unit1
- 21 CFR 211.67Equipment cleaning and maintenance1
- 21 CFR 211.160General requirements1
- 21 CFR 211.166Stability testing1
Ask FDAgent about process validation in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.