Skip to content

MicroBioPharm Japan Co., Ltd Form 483, February 2026

FDA issued this Form 483 to MicroBioPharm Japan Co., Ltd in Iwata, Japan (FEI 3003992082) at the end of a drug inspection that ended February 13, 2026. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 5, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 13, 2026
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 5, 2026
265 days after the inspection
Facility
FEI 3003992082
Iwata, Japan

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Unvalidated equipment cleaning procedures

    Your firm failed to establish adequate written procedures for cleaning and maintenance of equipment used in the manufacture, processing, or holding of drug substances, and failed to validate cleaning procedures to ensure that equipment is routinely cleaned to prevent contamination. Specifically, Your firm has not validated cleaning procedures for major manufacturing and processing equipment used in the production of active pharmaceutical ingredient (API) (b)(4) and API intermediates for (b)(4). The equipment that lacks validated cleaning procedures include, but are not limited to the following: API/Intermediate Process Equipment Name Equipment ID (b)(4)

  2. 2

    Inadequate equipment qualification procedures

    Your firm failed to establish and follow appropriate written procedures for equipment qualification. Specifically, Your firm has failed to establish and follow appropriate written procedures designed to ensure that equipment used in the manufacture of active pharmaceutical ingredients (APIs) and API intermediates is qualified for its intended use. The equipment that lacks adequate qualification or requalification include, but are not limited to, the following: API/Intermediate Process Equipment Equipment Name ID (b)(4) When requested during the inspection, your firm was unable to provide IQ/OQ documentation for the equipment listed above.

  3. 3

    Inadequate process validation with unqualified equipment

    Your process validations are inadequate. Specifically, You have performed a process validation for the manufacturing of the API (b)(4) (DMF# (b)(4)) using production equipment that have not been qualified. For example, the process verification protocols, (b)(4) have used major production equipment that have not been adequately qualified. (b)(4) The lack of equipment qualification undermines the validity of the process validation study, as there is no documented evidence that the equipment performs consistently and reliably within its intended operating ranges.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.