Skip to content

MicroBiopharm Japan Co., Ltd.

1808, Nakaizumi, Iwata, Japan

FEI 3003992082DUNS 498301338

Company: MicroBiopharm Japan Co., Ltd. · Linked by exact D-U-N-S match (680147586) in FDA registration data

FDA has 6 inspections on file for MicroBiopharm Japan Co., Ltd. in Iwata, Japan (FEI 3003992082), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's records.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant, MicroBiopharm Japan Co., Ltd. (D-U-N-S 680147586), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2009–2026
0 OAI · 6 VAI · 0 NAI
Inspections with 483 observations shown
2 of 6
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Oct 18, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unvalidated equipment cleaning procedures

      Your firm failed to establish adequate written procedures for cleaning and maintenance of equipment used in the manufacture, processing, or holding of drug substances, and failed to validate cleaning procedures to ensure that equipment is routinely cleaned to prevent contamination. Specifically, Your firm has not validated cleaning procedures for major manufacturing and processing equipment used in the production of active pharmaceutical ingredient (API) (b)(4) and API intermediates for (b)(4). The equipment that lacks validated cleaning procedures include, but are not limited to the following: API/Intermediate Process Equipment Name Equipment ID (b)(4)

    2. Observation 2

      Inadequate equipment qualification procedures

      Your firm failed to establish and follow appropriate written procedures for equipment qualification. Specifically, Your firm has failed to establish and follow appropriate written procedures designed to ensure that equipment used in the manufacture of active pharmaceutical ingredients (APIs) and API intermediates is qualified for its intended use. The equipment that lacks adequate qualification or requalification include, but are not limited to, the following: API/Intermediate Process Equipment Equipment Name ID (b)(4) When requested during the inspection, your firm was unable to provide IQ/OQ documentation for the equipment listed above.

    Show observation 3
    1. Observation 3

      Inadequate process validation with unqualified equipment

      Your process validations are inadequate. Specifically, You have performed a process validation for the manufacturing of the API (b)(4) (DMF# (b)(4)) using production equipment that have not been qualified. For example, the process verification protocols, (b)(4) have used major production equipment that have not been adequately qualified. (b)(4) The lack of equipment qualification undermines the validity of the process validation study, as there is no documented evidence that the equipment performs consistently and reliably within its intended operating ranges.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Valid stability test methods

      The written stability program for drug products does not include meaningful test methods.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Oct 18, 2026.

  • Inspection ending Feb 13, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Oct 18, 2026FDA-FOIA-2026-10125EIR· 1 of 3 sitesOpen
  • Inspection ending Feb 6, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Inspection records on Jul 7, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 29, 2026FDA-FOIA-2026-6197Inspection records· 1 of 3 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 on Apr 21, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 7, 2026FDA-FOIA-2026-3436Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 6 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2026
Registrant
MicroBiopharm Japan Co., Ltd.D-U-N-S 680147586

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names MicroBiopharm Japan Co., Ltd. (D-U-N-S 680147586) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003992082 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003992082. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.