Process validation in FDA Form 483 observations

Showing that a manufacturing process reliably makes product that meets its specifications: process validation, PPQ batches and continued process verification. FDAgent finds 78 such observations in 64 Form 483s issued to 62 facilities, for inspections that ended between January 2013 and July 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
78
Each quoted below
Form 483s
64
Posted by FDA
Facilities
62
Distinct FEIs
Most recent
Jul 17, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 20 in 2026

Process validation observations in Form 483s by inspection year
YearObservations
20131
20140
20150
20162
20175
20186
201911
20200
20212
20225
20237
20245
202514
202620

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.110(a)21 CFR 820.75

The same entries the process validation topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“process validation*” · “process performance qualification” · “PPQ” · “continued process verification” · “validation batch*” · “validation lot*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 78 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Smithfield Biosciencs, Inc.Inspection ended Dec 23, 2025 · FEI 1527761 · Observation 1

    Process Validation performed does not demonstrate that critical process parameters produce consistent APIs meeting their specifications and quality. Specifically, Your firm's process validation for (b) (4) USP, (b) (4) product codes, does not include validation of processing times listed in the batch record and in procedure SOP# 149. For example, (b) (4) (b) (4) (b) (4) cycle minimum times in the batch record were not tested, function was not …

    Contains “process validation*”Read the Form 483 →

  2. Macau-Union Pharmaceutical LimitedInspection ended Dec 17, 2025 · FEI 3011219786 · Observation 4

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, Your firm has not validated the production processes used to manufacture the over-the-counter finished human drug products intended for the U.S. market: (b)(4) (b)(4) Additionally, your firm …

    Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →

  3. Dr. Reddy’s Laboratories LimitedInspection ended Dec 12, 2025 · FEI 3009193040 · Observation 2

    OBSERVATION 2 Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. (b)(4) Specifically, you qualified your Tablet Compression Machine ID # PR034 and (b)(4)(b)(4) ID # PR034 in Room as per the Performance Qualification Report FTS1PRPR034-01 (Effective date 8/8/2013). On 3/16/2024 the …

    Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →

  4. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 8

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, A. Operators conducting (b) (4) for in-process testing on filling line (b) (4) filling) lack training and qualification. Operators are trained by reading procedures without hands-on experience …

    Opens with FDA's citation wording for 21 CFR 211.110(a)Read the Form 483 →

  5. Lonza AGInspection ended Oct 28, 2025 · FEI 3002930340 · Observation 1

    OBSERVATION 1 The information provided by the firm does not conform (b)(4) the (b)(4) drug substance (DS) shelf life shelf life applied to DS Process Performance Qualification (PPQ) batches (Batch (b)(4) PPQ batches (Batch (b)(4) was (b)(4)

    Contains “process performance qualification”Read the Form 483 →

  6. Implantica CE Reflux LimitedInspection ended Oct 24, 2025 · FEI 3015217460 · Observation 4

    Process validation activities have not been adequately documented. Specifically, the stated purpose of the validation protocol (test instructions) RS DVP0004 "RefluxStop Radiopacity and Barium Sulphate," was not congruent with the conclusions in the corresponding output report RS DVR0004. The protocol documentation was inaccurate.

    Opens with FDA's citation wording for 21 CFR 820.75(a)Read the Form 483 →

  7. Tripak Pharmaceuticals Pty Ltd.Inspection ended Jul 25, 2025 · FEI 3008549263 · Observation 3

    Failure to establish adequate written procedures for production and process controls. Specifically, Your process validation report VMP-VR0031.00 for the manufacturing of (b) (4) bulk fails to demonstrate that written procedures designed to assure that drug products have the identity, strength, quality, and purity they purport or are represented to possess are adequate. The validation lacks sufficient details regarding critical process parameters, …

    Contains “process validation*”Read the Form 483 →

  8. Foremount Enterprise Co., LtdInspection ended Jun 19, 2025 · FEI 3010402691 · Observation 4

    A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures. Specifically, your firm's Validation Management Procedure, QP732, V.05, dated March 26, 2025, and Validation Work Instruction, WI7312, V.02, dated March 27, 2025, have not been adequately established. Your firm is a Manufacturer and Contract Manufacturer of various medical devices to include …

    Opens with FDA's citation wording for 21 CFR 820.75(a)Read the Form 483 →

  9. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 1

    … These caps had not been scientifically evaluated prior to use to include actions including but not limited to change control, process validation and / or media fills. After this batch rejection, you documented CAPA-24-005 which includes the use of a new vendor cap. While CAPA-24-005 requires container closure integrity testing of approximately [illegible] units, it does not require such actions as process validation, stability testing and / or …

    Contains “process validation*”Read the Form 483 →

  10. Nanjing Cuccess Pharmaceutical Co., LtdInspection ended Mar 21, 2025 · FEI 3027129265 · Observation 1

    … process validation lots gy ®@ using this gg II. Approximately shared-use ey that operators use to transfer APT and other raw crials from bulk packaging to temporary vessels during weighing operations for all drugs manufactured in Workshop were inside a log tote: I observed unknown p, at the bottom of the tote with several gy os visibly soiled. Both the unknown gg RfP the utensils in the tote were designated clean. B. Workshop hm Room contains …

    Contains “process validation*”Read the Form 483 →

  11. Nanjing Cuccess Pharmaceutical Co., LtdInspection ended Mar 21, 2025 · FEI 3027129265 · Observation 2

    … Stability samples from the three process validation lots were placed into this long-term stability chamber in February 2024 and were inside the chamber during this requalification. B. I observed the monitoring and control sensors for temperature and humidity were located directly in front of the circulation fans at the top rear of chamber 911C49003 when I examined the interior on March 17, 2025. Stability chamber requalification protocol …

    Contains “process validation*”Read the Form 483 →

  12. Nanjing Cuccess Pharmaceutical Co., LtdInspection ended Mar 21, 2025 · FEI 3027129265 · Observation 3

    The written stability testing program is not followed. Specifically, your firm assigned ay shelf-life to the three yy process validation lots manufactured in January 2024. There was no accelerated stability study conducted at 40° Celsius and 949% relative humidity for six months to support the y 4 expiration date. Your firm released py process validation lot bw | expiration date gy ong and distributed the drug on about

    Contains “process validation*”Read the Form 483 →

  13. Shouguang Fukang Pharmaceutical Co., Ltd.Inspection ended Feb 21, 2025 · FEI 3003941038 · Observation 4

    … Additionally, your firm has not identified the hold time in the [illegible] as a critical step in the batch records, process validation, or any related SOPs.

    Contains “process validation*”Read the Form 483 →

  14. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 4

    … Investigation OOT-FQC22020 was opened during stability testing of process validation batches of (b1(~ 4 4 Tablets for the US market at the f (b)( timepoint. The product is labeled with ~ __ (bY{l expiration date and has a specification for unknown impurities of not more than ~. Batch [ (bH~ i had a result of ~ and 1 4 batch (b>C4 had a result of (bH% for unknown impurities. The production investigation identified inter- batch variability as the …

    Contains “process validation*”Read the Form 483 →

  15. Grifols Diagnostic Solutions Inc.Inspection ended Dec 13, 2024 · FEI 1000124057 · Observation 1

    Licensed Antigen Component Manufacturer for IVDs Your firm has not appropriately ruled out process validation for manufacturing of licensed antigen HCV c100-3 instead of using a verification approach, and your firm has not analyzed process data across all antigen types using your firm's CPV (b) (4) Reports to assess that manufacturing processes are in a qualified/validated state. A. Process Validation Master Plan, GDSE-VAL-VMP-000005, V21 & 22, …

    Contains “process validation*”Read the Form 483 →

  16. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 6

    Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A. Your firm has not performed Process Validation (PV) for finished products. You have considered performance of stability studies suitable to satisfy PV requirements. There are no documented / established …

    Contains “process validation*”Read the Form 483 →

  17. PCAS Finland OyInspection ended Jun 7, 2024 · FEI 3003469991 · Observation 1

    … Many of the unknown have remained (b)(4) percentages, which include consistent across commercial lots but with changes in increases relating to process validation lots and commercial lots, and many of which have acceptable LOD (Limit of Detection) and LOQ (Limit of Quantitation) for the in-house method. However, your firm has not investigated unknown per SOP Vaatimuksesta poikkeavien (OOS/OOT) laboratoriotulosten kasittely ja raportointi, …

    Contains “process validation*”Read the Form 483 →

  18. Apotex Research Private LimitedInspection ended Mar 15, 2024 · FEI 3006076314 · Observation 1

    Written records are not always made of investigations into unexplained discrepancies. Specifically, A) Your firm failed to investigate and identify the root cause of several low results observed for the (b) (4) data at the (b) (4) stage of (b) (4) Granules (b) (4)% for the PPQ batches. (b) (4) Granules (b) (4)% is the same (b) (4) used for all strengths of (b) (4). For example, the following mean values were recorded: (b) (4) Lots (b) (4) were …

    Contains “PPQ”Read the Form 483 →

  19. Apotex Research Private LimitedInspection ended Mar 15, 2024 · FEI 3006076314 · Observation 2

    … for assay trending upward with each subsequent unit operation including (b) (4) granules, and (b) (4) tablets during manufacturing of each of the following PPQ batches (b) (4) of (b) (4) (b) (4) mg Tablets. For example, the following values were observed for each of the aforementioned stages: (b) (4) (b) (4) B) Your firm failed to establish an acceptance criterion for the (b) (4) unit operation. (b) (4) (b) (4) testing is "for information only" …

    Contains “PPQ”Read the Form 483 →

  20. Jiangsu Intco Medical Products Co., LtdInspection ended Nov 17, 2023 · FEI 3005260401 · Observation 1

    Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm failed to retain records to support your process validation for OTC manufacturing. You did not maintain batch production records used as part of your process performance qualification for …

    Contains “process validation*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about process validation in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.