Apotex Research Private Limited Form 483, March 2024
FDA issued this Form 483 to Apotex Research Private Limited in Bengaluru, India (FEI 3006076314) at the end of a drug inspection that ended March 15, 2024. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 15, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 17, 2026
- 977 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate investigations of unexplained discrepancies
Written records are not always made of investigations into unexplained discrepancies. Specifically, A) Your firm failed to investigate and identify the root cause of several low results observed for the (b) (4) data at the (b) (4) stage of (b) (4) Granules (b) (4)% for the PPQ batches. (b) (4) Granules (b) (4)% is the same (b) (4) used for all strengths of (b) (4). For example, the following mean values were recorded: (b) (4) Lots (b) (4) were used (b) (4) of (b) (4) mg. B) The root cause for investigations LIR# 1530944 and LIR# 1530951 regarding anomalous results obtained at the (b) (4) time point during dissolution (b) (4) units) (b) (4) units) test of (b) (4) (b) (4) mg (b) (4) dissolution testing is not adequately justified. Dissolution profile study (b)(4) (b) (4) was performed for (b) (4) mg, Batch# (b) (4) PPQ according to protocol S2-PQP-3682-001-001, Revision: 1 (intended for USA market) and anomalous results of (b) (4)% were obtained in the (b) (4) time point. Based on initial investigation findings, no discrepancies were observed from the reagent, standard and sample preparations. However, the most probable cause for the observed anomalous results during dissolution test was determined to be due to contamination during test execution as it was hypothesized that the analyst did not place foil over the samples, despite the method not requiring this, and the standard spilled over onto the first row of samples only. All dissolution profile samples from other timepoints were present on the workbench at the same time observed acceptable results. C) The root cause for investigation LIR# 1223365 regarding anomalous result observed in (b) (4) (b) (4) sample testing for (b) (4) granules (b) (4)% ((b) (4) mg) PPQ batch (b) (4) is not adequately justified. (b) (4) (Lot (b) (4)) resulted in a (b) (4) of (b) (4)% which was performed as a part of protocol # S2-PQP-3386-001-001, Revision: 1 Titled as "PPQ for Protocol (b) (4) Granules (b) (4)% (USA Market) (S2-PQP-3386-001). (b) (4) results after (b) (4) stage are "for information only" without acceptance criteria. Based on phase 1 investigation findings, no assignable cause was identified for this anomalous result. The investigation was extended to manufacturing through SME PR # 1224409 and it was concluded that manufacturing process/procedure/instructions are not the contributing factor for the reported result. The firm performed testing of the two additional replicate (b) (4) samples and resulted in the assumption that the initial anomalous result is not a true result. It was hypothesized this high result to be from an addition of (b) (4) solution instead of sample (b) (4) into the specific (b) (4) volumetric flask unknowingly by the analyst. The root cause of this investigation is not justified and was ultimately attributed to analyst error without evidence.
- 2
No production and process control procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A) You have not identified the specific cause for assay trending upward with each subsequent unit operation including (b) (4) granules, and (b) (4) tablets during manufacturing of each of the following PPQ batches (b) (4) of (b) (4) (b) (4) mg Tablets. For example, the following values were observed for each of the aforementioned stages: (b) (4) (b) (4) B) Your firm failed to establish an acceptance criterion for the (b) (4) unit operation. (b) (4) (b) (4) testing is "for information only" despite being part of process validation.
- 3
Quality control unit procedures not followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A) Multiple anomalous results were obtained in (b) (4) test of (b) (4) Granules (b) (4)%. Investigations (LIR) have determined the root cause to being characteristic of the product at (b) (4) stage, however, no CAPA has been initiated to prevent anomalous results for (b) (4). (b) (4) CAPA has not been implemented for the following: LIR Batch Sub lot Mean %SD Anomalous result (b) (4) B) The Quality Unit has not ensured that all system suitability injections were performed in chromatographic sample set sequence for analyzing the degradation products for (b) (4) mg prior to injecting the samples. During the review of the degradation results of Batch (b) (4) (Stability Sample, RT (b) (4)) you failed to inject the Solution (b)(4) (system suitability solution) injection at the beginning of the sequence injections as a part of system suitability criteria per method degradation product (b) (4). Solution (b)(4) (system suitability solution) was injected and analyzed in separate chromatographic sequence. C) The Quality Unit failed to establish what is considered to be an anomalous result. For example, an investigation was initiated due to a result (b) (4)% (SD (b) (4)%) for (b) (4) of (b) (4) Granules (b) (4)% lot # (b) (4) however, an investigation was not initiated due to a result of (b) (4)% (SD (b) (4)%) for (b) (4) of (b) (4) Granules (b) (4)%. There is no justification why an investigation was performed for the (b) (4)% results and not the (b) (4)% result.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.