Skip to content

Lonza AG

Switzerland

FEI 3002930340DUNS 480007517

Company: Lonza Biologics Inc · Linked by exact D-U-N-S match (093149750) in FDA registration data

FDA has 8 inspections on file for Lonza AG in Switzerland (FEI 3002930340), from 2010 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. Two of the 13 FOIA requests for this site have asked FDA for this inspection's 483.

4 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant, Lonza Biologics Inc (D-U-N-S 093149750), has registered 14 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
8, 2010–2025
0 OAI · 5 VAI · 2 NAI
Inspections with 483 observations shown
2 of 8
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
13 requests, latest FY2023
Warning letters
None on file
Import refusals
4 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Drug substance shelf‑life nonconformance

      OBSERVATION 1 The information provided by the firm does not conform (b)(4) the (b)(4) drug substance (DS) shelf life shelf life applied to DS Process Performance Qualification (PPQ) batches (Batch (b)(4) PPQ batches (Batch (b)(4) was (b)(4)

    2. Observation 2

      Integrity test procedure deficiencies

      OBSERVATION 2 The (b)(4) (b)(4) integrity test procedure used for follow the vendor recommendations (document in 'Operation of (b)(4) (b)(4). For example: a. (b)(4) version: (b)(4) indicates to ___. However the (b)(4) or test set-up Figure (b)(4) the (b)(4) Manufacturing Executing System (MES) guidance b. (b)(4) version (b)(4) indicates that the include d j n SOP CHVI-346656 v2.0 or in c. (b)(4) version (b)(4) indicates to observe and disregard for: (b)(4) (observation time). i. The (b)(4) MES instructions indicate to start the timer immediately after the (b)(4) and conduct the test for ~ c (MES waiting time instruction parts) ii. SOP CHVI-346656 v2.0 step (b)(4) without mentioning any waiting time. d. (b)(4) version (b)(4) indicates that the integrity test passes (b)(4) (b)(4). The (b)(4) MES guidance for the operators indicate that the (b)(4)

    Show observations 3 to 4
    1. Observation 3

      PP/CPP deviations and OOS results

      OBSERVATION 3 Process Parameters (PPs) are not adequately controlled within established ranges manufacturing process. Specifically, PP deviations occurred during Batch (b)(4) manufacturing, including deviations for Critical Process Parameters (CPPs). In addition, Batch (b)(4) and Batch (b)(4) had out-of-specification (OOS) and borderline results, respectively, assay at release. The CPP deviations observed include: a. (b)(4) batch (b)(4) outside proven acceptable range during (b)(4) of production (b)(4). e PAR of n, (b)(4) and NO~ of h (b)(4) and (b)(4) as per CHVI-626612): at c % (b)(4) exceeded the (b) limit, and r)(4) limit. (b)(4) for (b)(4) c. (b)(4) Batch (b)(4) Excursion during the (b)(4) step for Batch b (b)(4). the acceptable range is (b)(4) (b)(4) Batch (b)(4) had OOS (b)(4) result of (b)(4). Batch (b)(4) had (b)(4) result of (b)(4) the lower specification limit (b)(4)

    2. Observation 4

      Critical materials and equipment maintenance issues

      OBSERVATION 4 Critical material used to manufacture (b)(4) lifetime. SRer.i:6r.::iJ1v._·______..., a. The (b)(4) integrity Tester used (b)(4) DSC (b)(4) between life _____, entering and damaging the instrument. and is replaced only when damaged. During the FDA inspection execution on October 24, 2025, a (b)(4) ______ through the (b)(4) in the results of the (b)(4). b. The (b)(4) instrument used to seal unique tracking number, and is not maintained or calibrated. c. The (b)(4) used for the (b)(4) do not have a preventative maintenance program. The product contact part (b)(4) and replaced b c. tth is "failure-based" (they are used until they fail, and then they are replaced). The facility has a single (b)(4) used for (b)(4) at the time (b)(4) compatible with the (b)(4) failure and was being repaired since on October 28, 2025.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete microbial and environmental monitoring records

      A) Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, You firm failed to report exact values for TAMC (Total Aerobic Microbial Count) action limit results as indicated in Lonza Test Method, Total Aerobic Microbial Count in (b) (4) Water, Doc. No.: CHVI-15464, Version: 11.0, Effective Date: 13-DEC-2022. For example, during the review of (b) (4) Water Trend Test Results from 2019-2022 (b) (4) I found the following action limit excursions only reported and trended as > (b) (4) CFU/ml but no exact counts are available, recorded or documented. 1. EAR-2579, 30-Jul-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 2. EAR-2581, 29-Jul-2019, (b) (4) WP TAMC > CFU/ml 3. EAR-2585, 31-Jul-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 4. EAR-2688, 14-Oct-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 5. EAR-3296, 28-Aug-2020, (b) (4) WP TAMC > (b) (4) CFU/ml 6. EAR-3707, 28-Jan-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 7. EAR-4108, 23-Apr-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 8. EAR-4119, 26-Apr-2021, (b) (4) WP TAMC > CFU/ml 9. EAR-4219, 25-May-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 10. EAR-7147, 14-Oct-2022, (b) (4) WP TAMC > (b) (4) CFU/ml 11. EAR-7345, 06-Dec-2022, (b) (4) WP TAMC > CFU/ml B) Your firm failed to report appropriate Environmental Monitoring action limit results as prescribed in Lonza SOP, Doc. No.: CHVI-5509, Version: 1.0, Effective Date: 23-NOV-2022. For example, during the review of Environmental Monitoring Trend Test Results from 2019-2022 (b) (4) I found the following action limit excursions only reported and trended as > (b) (4) CFU but no exact counts are available, recorded or documented. 1. EAR-2756, 28-Nov-2019, (b) (4) (b) (4) (Personnel (b) (4) > (b) (4) CFU 2. EAR-3130, 16-Jun-2020, (b) (4) Washing room (b) (4) > (b) CFU 3. EAR-3630, 06-Jan-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 4. EAR-4289, 16-Jun-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 5. EAR-4510, 04-Aug-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 6. EAR-4839, 15-Sep-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 7. EAR-7368, 07-Dec-2022, (b) (4) Fermentation (b) (4) > CFU Building (b) (4) (Bio Pharmaceutical Manufacturing) is used for the manufacturing of drug substance (b) (4) (b) (4) and (b) (4) for manufacturing drug substance (b) (4)

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

13 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Oct 28, 2025Not classified yet

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Feb 26, 2026FDA-FOIA-2026-2000Form 483Records released
    2. Date not givenFDA-FOIA-2026-4305Form 483· 1 of 14 sitesRecords released
  • Inspection ending Apr 4, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on May 29, 2026. FDAgent holds no copy that FDA posted.

    1. May 11, 2026FDA-FOIA-2026-4847Form 483· 1 of 2 sitesRecords released
  • Inspection ending Mar 1, 2023

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-5633Form 483Closed
  • Inspection date not given

    9 requests. FDA released records in answer to a request for its Form 483 on Apr 27, 2026. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2023-5136Form 483 + EIRClosed
    2. FY2023FDA-FOIA-2023-4965Form 483Closed
    3. FY2023FDA-FOIA-2023-4935Form 483 + EIRClosed
    4. FY2023FDA-FOIA-2023-4884Form 483Withdrawn
    5. May 14, 2026FDA-FOIA-2026-4928Form 483· 1 of 2 sitesRecords released
    6. May 1, 2026FDA-FOIA-2026-4353Form 483· 1 of 4 sitesRecords released
    7. Apr 21, 2026FDA-FOIA-2026-4029Form 483Records released
    8. Apr 21, 2026FDA-FOIA-2026-4021Form 483· 1 of 2 sitesRecords released
    9. Jun 27, 2024FDA-FOIA-2024-5605Form 483· 1 of 8 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002930340, one row per refused product line.

4 refusals from 2017-04-18 to 2022-10-25 · charged DIRSEXMPT on 2, UNAPPROVED on 2 · no FDA sample analysis

FDA firm profile
  • 2022-10-25

    INHIBITOR N.E.C.64UQS99

    DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING

    Division of Northern Border Imports231-9834119-5/31/1

  • 2022-10-25

    INHIBITOR N.E.C.64UQS99

    DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING

    Division of Northern Border Imports231-9834119-5/21/1

  • 2019-12-05

    ENZYME N.E.C.64EIS99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsBUP-1666854-6/11/1

  • 2017-04-18

    TETRACYCLINE (TETRACYCLINES)56EIA80

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northern Border ImportsAEK-3136666-6/11/1

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2026
Registrant
Lonza Biologics IncD-U-N-S 093149750

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Lonza Biologics Inc (D-U-N-S 093149750) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Lonza Bend Inc.Bend, Oregon · FEI 10006567894 inspections4latestMay 19, 2026VAINone on file
  • Lonza Bend Inc.Bend, Oregon · FEI 30037227435 inspections5latestMay 19, 2026VAINone on file
  • Lonza Houston Inc.New Hampshire · FEI 300145144110 inspections10latestApr 16, 2026None on file
  • Lonza Guangzhou Pharmaceutical Ltd.China · FEI 30065321865 inspections5latestOct 31, 2025None on file
  • Lonza Manufacturing LLCVacaville, California · FEI 30322995719 inspections9latestSep 29, 2025VAINone on file
  • Lonza Tampa LLCTampa, Florida · FEI 30015491096 inspections6latestAug 22, 2025VAINone on file
  • Lonza Biologics Porrino SLO Porrino, Spain · FEI 30060671694 inspections4latestApr 7, 2025VAINone on file
  • Lonza AGBasel Town, Switzerland · FEI 30147536482 inspections2latestJul 10, 2024VAINone on file
  • LONZA BIOLOGICS TUAS PTE. LTD.Singapore, Singapore · FEI 30097258455 inspections5latestJun 27, 2023VAINone on file
  • Lonza Biologics, plcSlough, United Kingdom · FEI 10005839594 inspections4latestOct 13, 2022VAINone on file
  • Lonza Houston, IncHouston, Texas · FEI 30136292141 inspection1latestDec 10, 2020NAINone on file
  • Lonza AGVisp, Switzerland · FEI 3012793444Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002930340 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002930340. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.