Lonza AG Form 483, March 2023
FDA issued this Form 483 to Lonza AG in Visp, Switzerland (FEI 3002930340) at the end of a drug inspection that ended March 28, 2023. It lists 1 observation. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 15, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 28, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 15, 2024
- 475 days after the inspection
The 1 observation on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Incomplete microbial and environmental monitoring records
A) Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, You firm failed to report exact values for TAMC (Total Aerobic Microbial Count) action limit results as indicated in Lonza Test Method, Total Aerobic Microbial Count in (b) (4) Water, Doc. No.: CHVI-15464, Version: 11.0, Effective Date: 13-DEC-2022. For example, during the review of (b) (4) Water Trend Test Results from 2019-2022 (b) (4) I found the following action limit excursions only reported and trended as > (b) (4) CFU/ml but no exact counts are available, recorded or documented. 1. EAR-2579, 30-Jul-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 2. EAR-2581, 29-Jul-2019, (b) (4) WP TAMC > CFU/ml 3. EAR-2585, 31-Jul-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 4. EAR-2688, 14-Oct-2019, (b) (4) WP TAMC > (b) (4) CFU/ml 5. EAR-3296, 28-Aug-2020, (b) (4) WP TAMC > (b) (4) CFU/ml 6. EAR-3707, 28-Jan-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 7. EAR-4108, 23-Apr-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 8. EAR-4119, 26-Apr-2021, (b) (4) WP TAMC > CFU/ml 9. EAR-4219, 25-May-2021, (b) (4) WP TAMC > (b) (4) CFU/ml 10. EAR-7147, 14-Oct-2022, (b) (4) WP TAMC > (b) (4) CFU/ml 11. EAR-7345, 06-Dec-2022, (b) (4) WP TAMC > CFU/ml B) Your firm failed to report appropriate Environmental Monitoring action limit results as prescribed in Lonza SOP, Doc. No.: CHVI-5509, Version: 1.0, Effective Date: 23-NOV-2022. For example, during the review of Environmental Monitoring Trend Test Results from 2019-2022 (b) (4) I found the following action limit excursions only reported and trended as > (b) (4) CFU but no exact counts are available, recorded or documented. 1. EAR-2756, 28-Nov-2019, (b) (4) (b) (4) (Personnel (b) (4) > (b) (4) CFU 2. EAR-3130, 16-Jun-2020, (b) (4) Washing room (b) (4) > (b) CFU 3. EAR-3630, 06-Jan-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 4. EAR-4289, 16-Jun-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 5. EAR-4510, 04-Aug-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 6. EAR-4839, 15-Sep-2021, (b) (4) Fermentation (b) (4) > (b) (4) CFU 7. EAR-7368, 07-Dec-2022, (b) (4) Fermentation (b) (4) > CFU Building (b) (4) (Bio Pharmaceutical Manufacturing) is used for the manufacturing of drug substance (b) (4) (b) (4) and (b) (4) for manufacturing drug substance (b) (4)
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3002930340, newest first.
- Form 483, October 2025FDA record date Oct 28, 2025 · Posted Apr 24, 2026
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.