PCAS Finland Oy
Messukentankatu 8, Turku, Finland
FEI 3003469991DUNS 369587311
FDA has 8 inspections on file for PCAS Finland Oy in Turku, Finland (FEI 3003469991), from 2008 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant is PCAS Finland Oy (D-U-N-S 369587311).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2008–2024
- 0 OAI · 7 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 8
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Jul 8, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate unknown impurities
Your firm has not investigated unknown [illegible] (including one known [illegible]) as indicated by an in-house analytical (b)(4) method. An "in-house" (b)(4) method is indicated in SOP titled Method Analysis, DOC-00010295, among other tests (e.g., other in-house and API release tests), under (b)(4) product code [illegible]. Results of the in-house method is reported to the sponsor (product owner). The (b)(4) indicates unknown as the in-house method indicates more resolved reference [illegible] vs. the official API release method for your firm. Many of the unknown have remained (b)(4) percentages, which include consistent across commercial lots but with changes in increases relating to process validation lots and commercial lots, and many of which have acceptable LOD (Limit of Detection) and LOQ (Limit of Quantitation) for the in-house method. However, your firm has not investigated unknown per SOP Vaatimuksesta poikkeavien (OOS/OOT) laboratoriotulosten kasittely ja raportointi, DOC-00002873 (English: Processing and reporting of non-conforming laboratory results (OOS/OOT)). In addition, one major known (b)(4) can only be seen using the in-house method. This is expected but has not been investigated as to whether the amount is an acceptable output of the manufacturing process. The following most recent API batches have been released and distributed: (b)(4)
- Observation 2
No maintenance procedures for API equipment
Failure to maintain equipment used for the manufacturing of API. Specifically, your firm has not established procedures for the maintenance of (b)(4) (equipment ID: [illegible]) (equipment ID: [illegible]) equipment used for the (b)(4) and (b)(4) manufacturing of [illegible] Active Pharmaceutical Ingredient (API). There is no written procedure for inspection, component replacement, calibration or other maintenance frequency/schedule for this equipment.
Show observation 3
- Observation 3
Poor upkeep of bioburden-controlled facilities
Your firm has not repaired and maintained manufacturing spaces & equipment in which bioburden-controlled manufacturing processes are conducted for API. On 05 JUN 2024, the following conditions were observed: a) Two holes (apparently about the diameter of a U.S. quarter) were observed in an exhaust vent [illegible] (Equip (b)(4)) (located in room [illegible]) reported as meeting an [illegible] ISO-standard), and which continues as part of the air system. The [illegible] of your firm's [illegible] is used to conduct key bioburden-controlled steps in [illegible] manufacturing process (e.g., processes such as (b)(4)). b) Regarding the condition of room [illegible] (in which (b)(4) of manufacturing occur and in which certain steps in the [illegible] of manufacturing occurs; and reported as meeting an ISO standard). i. Two room air intake vents appear to be partially blocked or positioned near cabinets such that effective air flow may be compromised. ii. The sealant used to fill ceiling interfaces appears to be cracked and discolored. iii. (b)(4) used to cover cracks in the floor, appears to be buckling and/or deteriorating.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 8, 2026. Each one asked for a Form 483.
Inspection ending Jun 7, 2024VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 8, 2026FDA-FOIA-2026-6507Form 483· 1 of 5 sitesRecords released
- Nov 26, 2024FDA-FOIA-2024-10415Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- PCAS Finland OyD-U-N-S 369587311
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003469991 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003469991. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.