Orean Personal Care Ltd
Unit E1, Stubs Beck Lane, Cleckheaton, United Kingdom
FEI 3010999645DUNS 211403363
FDA has 3 inspections on file for Orean Personal Care Ltd in Cleckheaton, United Kingdom (FEI 3010999645), from 2017 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.100(a), 21 CFR 211.63 and 21 CFR 211.84(d)(2).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and packing, through Dec 31, 2027. Its registrant is Orean Personal Care Ltd. (D-U-N-S 211403363).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2017–2026
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Aug 14, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Cleaning validation for non-dedicated equipment lacking
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, you manufacture Over the Counter (OTC) drug products for the US market on non-dedicated manufacturing equipment. You designed a cleaning matrix that identified most difficult product to clean, (b)(4) FDA product Code No. (b)(4) also called (b)(4). You did not validate the respective cleaning procedures such that, A. You clean your manufacturing vessels (b)(4) according to the cleaning procedure/check list, WIM020 OTC Cleaning and Sanitizing Vessel Check Sheet. You recorded the data for cleaning validation in, Cleaning Validation Report for Cleaning Process WIM020 On Manufacturing Vessel Issued on 9/11/2025. The report contains cleaning data after manufacturing a single batch of (b)(4) in (b)(4). Your Quality Head (b)(6) stated that the batch number for drug product, (b)(4) was not available. B. You clean your tube filling line (Line (b)(4)) according to a cleaning procedure/check list, WIPROD008 OTC Cleaning and Sanitising Tuber Check Sheet. You recorded the data for cleaning validation in, Cleaning Validation Report for Cleaning Process WIPROD008 on Tube Fillers Issued on 9/9/2025. The report contains cleaning data after manufacturing a single batch in Line (b)(4). Your Quality Head (b)(6) stated that the batch number for drug product, (b)(4) of (b)(4) was not available. C. You clean your (b)(4) filling line (Line (b)(4)) according to a cleaning procedure/check list, WIPROD007 OTC Cleaning and Sanitising Line Check Sheet. You recorded the data for cleaning validation in, Cleaning Validation Report for Cleaning Process WIPROD007 on (b)(4) Filling Line, Issued on 9/11/2025. The report contains cleaning data after manufacturing a single batch of (b)(4) in Line (b)(4). Your Quality Head (b)(6) stated that the batch number for drug product, (b)(4) was not available. None of your cleaning validation protocols and/or reports have the equipment design to identify the swabbing locations. Your Quality Head (b)(6) confirmed that the transfer pipes and hoses used in the manufacturing were not product dedicated and were not part of the cleaning validation. On 2/17/2026, during walkthrough of your manufacturing area, I saw pipes and hoses hanging on the walls without any (clean/to-be-cleaned/dirty) status. Your Quality Head (b)(6) stated that the hoses and pipes were in clean status. I checked inside of one of the hoses with a paper towel. The surface of the paper towel that rubbed the inside of the hose became soiled with material. Your Quality Head (b)(6) stated that these pipes will be cleaned one more time when they are picked up for the manufacturing and all the manufacturing equipment are verified for sanitization through a Sanitization Equipment Check List FDA F023. You currently manufacture (b)(4) drug products for the US market and (b)(4) across your multiple different (b)(4) for the UK. You use the (b)(4) to clean these (b)(4). You did not have any scientific justification why (b)(4) is the most difficult material to clean in comparison to many of your US product. In addition, the non-dedicated hose and pipes also present opportunity for cross contamination of the US products with that of the actives present in many of (b)(4) products that are manufactured in your facility. You have no data to confirm how easy or difficult to [illegible].
- Observation 2
Quality control unit procedures not written or followed
The responsibilities and procedures applicable to the quality control unit are not in writing and/or fully followed. Specifically, A. You released the batches of finished products before completing all the test to ensure the OTC drug products meet all the specification. Your procedure, WIPROD027 OTC Products Sampling and Processes Version 12 (Issued on 11/28/2024) require a review of all the test to ensure the product meets specification for the prior to releasing the batch. Your Quality Head (b)(6) stated that the firm released the batches under quarantine as per the quality agreement with the customer. You shared a generic quality agreement with the respective customer that was created on September 2024 and signed but not dated. The QA is also open ended without an expiry/re-certification timeline. B. You did not initiate deviations for delayed stability studies. Specifically, you initiated Long Term stability studies for the process validation batches after >3 months from the date of manufacturing. Your Quality Head (b)(6) stated that the firm did not have a deviation procedure and shared a form, OTC Deviation Form FDAF012 Version 1 that the firm uses to record deviations. C. You did not follow your FDA Change Control Procedure, FDASOP001 Version 1 such that you did not initiate change control prior to revising the batch manufacturing records. Specifically, during the process validation, you made several modifications into the first process validation batches to bring the batch in specification. You then updated the manufacturing instructions for subsequent batches and completed the process validation. You did not initiate change controls to evaluate the impact of changes on the overall drug product quality. As of 2/20/2026, you have not initiated any change control for your manufacturing site. D. You did not conduct accelerated stability study for the OTC drug products that you manufacture for the US market. You shared data for accelerated study that did not have batch numbers. Your Quality Head (b)(6) stated that these data were generated from the lab batches and not from the commercial batch. E. Your procedure, Annual Product Quality Review for OTC Product WIT021 Version 5.0 (Issued on 9/10/2024) does not have provision for trending key quality attributes as a way to monitor the manufacturing process. In 2024, you manufactured (b)(4) batches of (b)(4). You did not include/trend the manufacturing data and test results in respective Annual Product Quality Review for OTC Form QAF003 Version 1.0 (Effective date 4/1/2025). You also did not conduct annual quality review for your (b)(4) that is used as raw material for OTC drug products. F. You do not have quality agreements with the suppliers of API (b)(4). The release test and stability study of your drug products is carried out at a third-party lab (b)(4). You do not have quality agreement with this (b)(4) lab. G. There are not written procedures that guide the production of (b)(4) or the cleaning/maintenance of the (b)(4) system used for the production of OTC drug products and the cleaning of equipment of the (b)(4) used to produce OTC drug products. H. You did not follow your procedure, Control of Quality Documents Version 1 dated 11/27/2024 to ensure all the documents and data related to the US OTC drug products are secured and the most current version are in use. During walkthroughs and document review, several deficiencies were observed, e.g. a. In your production lab, loose sheets of the pH calibration test data (for 2024 and 2025, 2026) were stored. The data were not reviewed by the quality assurance. Your Quality Head (b)(6) was not sure why old data were not bounded and archived. b. The Cleaning Validation Protocols and Reports were not reviewed and signed by quality assurance. c. The Process Validation Protocol and Reports were not reviewed and signed by quality assurance.
Show observations 3 to 7
- Observation 3
Laboratory controls and water system monitoring deficient
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, test procedures designed to assure that components of drug product, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A. Your firm failed to monitor the (b)(4) system to ensure that it consistently produces (b)(4) that, at a minimum, meets the USP monograph for (b)(4) at the point of use. Furthermore, your firm uses the (b)(4) for equipment cleaning and as a raw material in OTC drug products exported to the US, including but not limited to the bulk batches manufactured (and tested in the production lab) for the US market between 1/28/2026 and 2/16/2026, which are summarized below in Table 1. On multiple occasions during 2025, your (b)(4) exceeded your upper limit of (b)(4) yet no investigation or deviation was implemented to determine the cause of the out of specification (b)(4). In addition, the (b)(4) was consistently outside the parameters of your pre-determined range over the course of 2025. In 2025, a risk assessment was conducted to raise the range to (b)(4) with no scientific rational as to why the upper limit was raised to (b)(4). The test methods for microbial and chemical testing are not validated. Some of the batches manufactured for the US market include but are not limited to: (b)(4). B. The (b)(4) system was not qualified when installed in 2022 and complete preventative maintenance records are not kept of the (b)(4) system, including the cleaning and sanitization of the system. You do not have a written procedure that guides the sampling, sanitizing, cleaning and maintenance of the (b)(4) system. C. On 2/16/2026, an expired standard of pH 7.0 buffer (Lot #(b)(4)) was found in your production lab. The label on the bottle read, the Recommended use by date 1/28/2026. You calibrate your pH meter in the production lab with pH 4.0 and pH 7.0 standards. There was no other pH 7.0 standard in the lab. On 2/19/2026, your Quality Head (b)(6) stated that on 2/16/2026, the firm placed a new pH 7.0 standard (Lot #(b)(4) Recommended use by date 9/17/2027) in the production lab. The bulk batches manufactured (and tested in the production lab) for the US market between 1/28/2026 and 2/16/2026 are summarized in Table 1. Table 1. Bulk batches manufactured for the US market between 1/28/2026 - 2/16/2026 [Table with Date, Product Name, Product Code, Batch No., Batch Size - details redacted as (b)(4)].
- Observation 4
Production process validation lacking for OTC products
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, you currently manufacture (b)(4) OTC drug products for the US market. You have not validated the respective manufacturing processes such that, A. You designed the process validation protocol, PVal014 for (b)(4) batches at (b)(4) from (b)(4) batch size. According to your Process Validation Report, the first batch failed. You added a (b)(4) batch at (b)(4) to complete the process validation. You have manufactured commercial batches that range in (b)(4). Your Production Head (b)(6) stated that the process validation batch size, (b)(4) batch sizes were designed to utilize the minimum and maximum working volume of the (b)(4) capacity. Mr. (b)(6) also stated that the commercial batches sizes are executed as per the customer order. B. You designed the process validation protocol, PVal017 for (b)(4) batches at (b)(4) from (b)(4) batch size. You have manufactured (b)(4) commercial batch at (b)(4) batch size. Your Production Head (b)(6) stated that the process validation batch sizes were designed to utilize the minimum and maximum working volume of the (b)(4) capacity. Mr. (b)(6) also stated that the commercial batches sizes are executed as per the customer order. C. You designed the process validation protocol, PVal015 for (b)(4) batches at (b)(4) from (b)(4) batch size. According to your Process Validation Report, the first batch failed. You added a (b)(4) batch at (b)(4) to complete the process validation. You have manufactured commercial batches that ranges in (b)(4) batch sizes. Your Production Head (b)(6) stated that the process validation batch size, (b)(4) batch sizes were designed to utilize the minimum and maximum working volume of the (b)(4) capacity. Mr. (b)(6) also stated that the commercial batch sizes are executed as per the customer order. The finished product, (b)(4) mL Batch No's (b)(4) bulk batches manufactured from the (b)(4) failed at time t = 0 for the long-term (25 +/- 5 C/60 +/- 5% RH) stability study that is carried out at a third party. The (b)(4) also failed for (b)(4). In addition, Batch No. (b)(4) failed for pH (b)(4) against Specification (b)(4) [and] for viscosity (b)(4) cps against Specification (b)(4) cps. You have shipped a total of (b)(4) units from these implicated batches to the US market. You did not investigate the OOS results as of 2/20/2026.
- Observation 5
Failure to investigate stability OOS results
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. On 12/26/2025, your vendor (b)(4) who carries out stability study has recorded OOS result for (b)(4) mL. The OOS result was recorded for Batch No. (b)(4) (Mfg. date 7/7/2025 Expiry date (b)(4)) for pH (b)(4) against the Specification (b)(4) [at] the initiation (t = 0) of long-term (25 +/- 5 degrees C/60 +/- 5% RH) stability study. The OOS result was confirmed via Re-Measurement Testing. No Laboratory Assignable Root Cause was found. Your vendor (b)(4) communicated to you to initiate Phase II full scale manufacturing investigation. As of 2/20/2026, you did not take any action and did not share any investigation report. You have shipped (b)(4) units of the above implicated batch to the US market. B. On 12/26/2025, your vendor (b)(4) who carries out stability study recorded OOS result for (b)(4) mL. The OOS result was recorded for Batch No. (b)(4) (Mfg. date 8/15/2025 Expiry date (b)(4)) for pH (b)(4) against the Specification (b)(4) at the initiation (t = 0) of long-term (25 +/- 5 degrees C/60 +/- 5% RH) stability study. The OOS result was confirmed via Re-Measurement Testing. No Laboratory Assignable Root Cause for found. Your vendor (b)(4) communicated to you to initiate Phase II full scale manufacturing investigation. As of 2/20/2026, you did not take any action and did not share any investigation report. You have shipped (b)(4) units of the above implicated batch to the US market. C. On 1/12/2026, your vendor (b)(4) who carries out stability study recorded OOS result for (b)(4) mL. The OOS result was recorded for Batch No. (b)(4) (Mfg. date 8/22/2025 Expiry date (b)(4)) for pH (b)(4) against the Specification (b)(4) and Viscosity (b)(4) cps against Specification (b)(4) cps at the initiation (t = 0) of long-term (25 +/- 5 degrees C/60 +/- 5% RH) stability study. The OOS result was confirmed via Re-Measurement Testing. No Laboratory Assignable Root Cause for found. Your vendor (b)(4) communicated to you to initiate Phase II full scale manufacturing investigation. As of 2/20/2026, you did not take any action and did not share any investigation report. You have shipped (b)(4) units of the above implicated batch to the US market. Your Regulatory Head (b)(6) and Quality Head (b)(6) stated that there were minor differences in the pH and Viscosity. These non-conformances are not likely to cause harm to the patients/users. Your procedure, FDA Out of Specification FDASOP002 Version 1 (Issued date 6/10/2025) requires investigation to close within (b)(4) or an extension is approved by QA. On 2/20/2026, your Quality Head (b)(6) confirmed there was no report or extension available to share/review.
- Observation 6
Component sampling procedures lacking detail
Written procedures are lacking which describe in sufficient detail the receipt, sampling and testing of components of drug products. Specifically, your procedure, OTC Products Sampling and Process WIPROD027 Version 12 (Issued on 11/28/2024) does not contain information about collecting a representative sample. You are in the process of vendor qualification for (b)(4). As of now you have completed the testing of (b)(4) batches of (b)(4) Batch No's (b)(4). Each batch was received as a (b)(4) lot size in (b)(4) bags of (b)(4) each. Your Quality Head (b)(6) stated that one sample from one of the bags from each batch was sent to the testing laboratory for full scale testing. Mr. (b)(6) also stated that sample was collected for each lot for the testing and this sampling was not recorded in the ERP system. Mr. (b)(6) also confirmed that there was no attributing document to verify that a sample of (b)(4) was collected at the site and shipped to the outside lab.
- Observation 7
Failure to store components preventing contamination
There was a failure to handle and store components of drug product at all times in a manner to prevent contamination. Specifically, on 2/16/2026 during the walkthrough of your warehouse, I saw a bag of Lot No. (b)(4) Mfg. date May 2025 Expiry date (b)(4) of (b)(4). I saw the bag left open and was not sealed/secured. I also saw (b)(4) material in a (b)(4) bag on top of a carton of (b)(4) that belonged to one of the cartons with the Lot No. (b)(4). Your Quality Head stated that the (b)(4) looking (b)(4) Lot No. (b)(4) were (b)(4) that was used to manufacture OTC drug products for the US market. e.g. (b)(4).
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Show 2 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful and specific test methods.
Drug product sample
Drug product samples are not representative of the entire batch.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
Calibration/Inspection/Checking not done
Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Show 2 more citations
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 14, 2026. Each one asked for a Form 483.
Inspection ending Feb 20, 2026OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 14, 2026FDA-FOIA-2026-7888Form 483· 1 of 5 sitesRecords released
- Jun 8, 2026FDA-FOIA-2026-5624Form 483· 1 of 2 sitesRecords released
Inspection ending Mar 15, 2024OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 3, 2024FDA-FOIA-2024-5862Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.63Equipment design, size, and location2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.80General requirements1 of 2
- 21 CFR 211.103Calculation of yield1 of 2
Show all 11
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing
- Registration runs through
- Dec 31, 2027
- Registrant
- Orean Personal Care Ltd.D-U-N-S 211403363
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010999645 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010999645. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.