How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
231
Each quoted below
Form 483s
161
Posted by FDA
Facilities
150
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 67 in 2026

Investigations and OOS results observations in Form 483s by inspection year
YearObservations
20101
20110
20123
20131
20141
20153
20169
201712
201812
201917
20202
202111
202220
202321
202416
202535
202667

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.192

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 231 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. GlaxoSmithKline Biologicals Kft.Inspection ended Jan 31, 2025 · FEI 3008322822 · Observation 1

    Discrepancy and failure investigations related to manufacturing were not expanded to assess worst case conditions. Specifically, a) Deviation 201042740 initiated on 09JAN2024, pertaining to particulate contamination of (b)(4) was not adequately investigated. Your (b)(4) sent for analysis during the [illegible] identified an (b)(4) within a (b)(4) deviation investigation. However, you failed to perform an adequate risk analysis that included worst …

    Contains “not … investigated”Read the Form 483 →

  2. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 4

    OBSERVATION #4 There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. 1. Deviation DF-23012 was opened when foreign matter was observed d.m_____(bTI of batch (bH f (bf~ able g (US Market). The batch was rejected. The investigation failed to perform any identification of the foreign matter or take …

    Contains “thoroughly review*”Read the Form 483 →

  3. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 1

    … There was no investigation conducted to determine the impact of these out of specification results on those drug products which had been distributed to the US market. [illegible] unique drug products were manufactured in the year 2019, however only 4 of these drug products were placed on stability.

    Contains “out of specification”Read the Form 483 →

  4. Janssen Vaccines CorporationInspection ended Nov 19, 2024 · FEI 3012637764 · Observation 1

    … (Effective date 5/25/2024) Section 7.11.1.2 that sets the requirement for FAR (BPDR) as, "***Two or more complaints with the same confirmed defect with same root cause for the same finished good lot or a root cause related to a common component lot in more than one finished good lot, with or without signal***". Your procedure, TV-SOP-31402 Version 6.0 Advisory Notices, US FDA Form 3911 (Drug Notification and Health Authority (HA) Communication - …

    Contains “root cause*”Read the Form 483 →

  5. Janssen Vaccines CorporationInspection ended Nov 19, 2024 · FEI 3012637764 · Observation 4

    … No root cause was determined.

    Contains “root cause*”Read the Form 483 →

  6. AnazaoHealth CorporationInspection ended Sep 23, 2024 · FEI 3011152407 · Observation 1

    Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, A. On April 12, 2024, your control testing laboratory analyzed the potency of riboflavin in your human sterile drug product PlenishIV Nutrient Cocktail lot (B)(4) and found that the chromatogram of the sample "showed different peaks" than the …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  7. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, During your firm's visual inspection of Buffered Lidocaine HCl USP 2% 20mg/mL, 50mL Vials for injection Lot (b) (4) MFG 08/30/2022, (b) (4) vials were rejected due to defects including particles, package defects, sealing …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  8. Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 5

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. A. Laboratory Investigation AV 2023-348 for (b) (4) mg/ml, (b) (4) ml vial, lots (b) (4) Exp. Dates (b) (4) and (b) (4) was initiated on 11/23/2023 due to out-of-trend (OOT) and out-of-specifications (OOS) assay results. Specifically, OOT …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  9. Protherics UK LimitedInspection ended Aug 13, 2024 · FEI 3001417487 · Observation 1

    Your firm has not fully investigated or assessed the impact of finding various molds in a (b)(4) room in which manufacturing materials (used for manufacturing of (b)(4) and (b)(4)) and stability samples are held. From March 2023 to April 2024, five quality investigations were initiated to address molds in (b)(4) room of a (b)(4) and include: #70445; #73010; #73044; DEV-00267; and DEV-00331. These investigations were generated in accordance with …

    Contains “not … investigated”Read the Form 483 →

  10. Serum Institute of India Pvt. Limited Manjari SiteInspection ended Jul 2, 2024 · FEI 3020223359 · Observation 1

    … A thorough investigation was not conducted to identify a root cause of the positive (b) (4) and confirm the ability of your (b) (4) to (b) (4) areas where positive (b) (4) were found.

    Contains “root cause*”Read the Form 483 →

  11. PCAS Finland OyInspection ended Jun 7, 2024 · FEI 3003469991 · Observation 1

    Your firm has not investigated unknown [illegible] (including one known [illegible]) as indicated by an in-house analytical (b)(4) method. An "in-house" (b)(4) method is indicated in SOP titled Method Analysis, DOC-00010295, among other tests (e.g., other in-house and API release tests), under (b)(4) product code [illegible]. Results of the in-house method is reported to the sponsor (product owner). The (b)(4) indicates unknown as the in-house …

    Contains “not … investigated”Read the Form 483 →

  12. Swati Spentose Private LimitedInspection ended May 31, 2024 · FEI 3009765202 · Observation 2

    The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm failed to ensure that all Quality Control (QC) laboratory personnel perform product testing according to approved testing procedures. Over one hundred OOS/Incidents investigations have been concluded as human errors since Jan 2021 despite ongoing retraining and requalification of analysts. Human errors in the QC lab such as …

    Contains “OOS”Read the Form 483 →

  13. Alkem Laboratories LimitedInspection ended Mar 27, 2024 · FEI 3006370533 · Observation 1

    QUALITY SYSTEM OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. During the preventive maintenance of Perkin Elmer UV Spectrophotometer ID #G/QC/225 connected to software and computer (UV WinLab ES 6.5.0.103 and computer ID #ABA/EQ/QC/COM/01187) on 06/28/2023, …

    Contains “thoroughly review*”Read the Form 483 →

  14. Apotex Research Private LimitedInspection ended Mar 15, 2024 · FEI 3006076314 · Observation 1

    Written records are not always made of investigations into unexplained discrepancies. Specifically, A) Your firm failed to investigate and identify the root cause of several low results observed for the (b) (4) data at the (b) (4) stage of (b) (4) Granules (b) (4)% for the PPQ batches. (b) (4) Granules (b) (4)% is the same (b) (4) used for all strengths of (b) (4). For example, the following mean values were recorded: (b) (4) Lots (b) (4) were …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  15. Apotex Research Private LimitedInspection ended Mar 15, 2024 · FEI 3006076314 · Observation 3

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A) Multiple anomalous results were obtained in (b) (4) test of (b) (4) Granules (b) (4)%. Investigations (LIR) have determined the root cause to being characteristic of the product at (b) (4) stage, however, no CAPA has been initiated to prevent anomalous results for (b) (4). (b) (4) CAPA has not been implemented for the …

    Contains “root cause*”Read the Form 483 →

  16. Medimmune U.K. LimitedInspection ended Mar 15, 2024 · FEI 3004066112 · Observation 3

    [illegible] from the (b)(4) during Jan 25 - Mar 8, 2023 recorded in the qualification report of the (b)(4) from (b)(4). a. No deviation was initiated for these consecutive action level excursions on %(b)(4) of the (b)(4) as per SOP-0067565. b. The rejected (b)(4) were not manually inspected to verify that the (b)(4) were in poor quality prior to concluding that the root cause was due to the malfunction of the light and camera.

    Contains “root cause*”Read the Form 483 →

  17. GSK Vaccines GmbHInspection ended Mar 6, 2024 · FEI 3001314775 · Observation 2

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, investigation related to (b) (4) of Aluminum Hydroxide (b) (4) is not adequate. Aluminum Hydroxide is an adjuvant used for Infanrix, (b) (4), Pediarix, and Boostrix Vaccine products for US market. On 06Apr2023, (b) (4) and (b) (4) were observed on the (b) (4) of (b) (4), which is used for the (b) (4) of Aluminum …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  18. Fukuzyu Pharmaceutical Co., Ltd.Inspection ended Jan 19, 2024 · FEI 3002807025 · Observation 1

    The quality unit does not always conduct thorough investigations for out-of-specification results and critical deviations. Specifically, A) Your firm opened OOS 220202-1 on 02/02/2022 to investigate the OOS result for ----- assay in (b)(4) (b)(4) (b)(4) (b)(4). The reprocessed rate of the initial results was [illegible] which exceeds the (b)(4) specification of (b)(4). The investigation indicated the most likely root cause of the OOS was weighing …

    Contains “out of specification”Read the Form 483 →

  19. Laurus Synthesis Private LimitedInspection ended Dec 12, 2023 · FEI 3011524794 · Observation 1

    … OOS investigation OOS/LSV1/001/22 identified improper in-process sampling as suspected cause for impurity by HPLC for key starting material (b) (4). The investigation infers that the operator collected samples only from the (b) (4) in process material and therefore the assay passed during in-process testing and failed for impurity during finished testing. However, procedure MFG/027, "In-process sampling", does not specify the correct sampling …

    Contains “OOS”Read the Form 483 →

  20. Alkem Laboratories LimitedInspection ended Dec 1, 2023 · FEI 3008450172 · Observation 2

    Investigations are inadequate in that they do not evaluate all potential root causes of unexpected results nor are they adequately extended to potentially impacted API. Specifically, A- On December 10, 2022, a fire ensued in Plant-(b) (4) The fire caused damage to all of the technical area of Plant-(b) (4) Your firm investigated the incident through Deviation M/DEV/2022/0031 with closing date of April 20, 2023. In reviewing the deviation, your …

    Contains “root cause*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about investigations and OOS results in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.