Serum Institute of India Pvt. Limited Manjari Site Form 483, July 2024
FDA issued this Form 483 to Serum Institute of India Pvt. Limited Manjari Site in Pune, India (FEI 3020223359) at the end of a biologics inspection that ended July 2, 2024. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 2, 2024
- Biologics · Vaccines and Allergenic Products
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 17, 2026
- 868 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate requalification of filling area sterilization
Requalification of the (b) (4) used to (b) (4) the filling (b) (4) filling line and (b) (4)) where COVID vaccine is filled into syringes is inadequate. Specifically, the maximum load runs performed during re-qualification of the (b) (4) failed your acceptance criterion for observing positive (b) (4) in 2022 and during (b) (4) requalification run in 2023. In addition, positive (b) (4) were found in the same nearby locations during requalification of the (b) (4) of the vial filling line in 2023 and 2024. A thorough investigation was not conducted to identify a root cause of the positive (b) (4) and confirm the ability of your (b) (4) to (b) (4) areas where positive (b) (4) were found.
- 2
Insufficient cleaning validation preventing cross-contamination
With the current acceptance criteria of the (b) (4), there is insufficient data to support that the current cleaning of the (b) (4) can assure no (b) (4) between vaccine products when the same (b) (4) are used in production with different (b) (4).
- 3
Incomplete validation study for reuse performance
There is insufficient data in the (b) (4) validation study to support comparable (b) (4) performance with respect to (b) (4) of (b) (4) for (b) (4) uses of (b) (4) and (b) (4) uses of (b) (4). In addition, the (b) (4) for the (b) (4) (b) (4) was not evaluated in the study. This deficiency was previously identified during the last inspection in April 2022, and you committed to have the completed (b) (4) report by December 31, 2022. However, at the time of this inspection, the study has still not been completed.
- 4
Lack of data for reference standard qualification
There is a lack of (b) (4) data in the qualification report for (b) (4) reference standard lot # (b) (4). The (b) (4) is used to (b) (4) of this reference standard and serves as supportive information for the (b) (4) for the release of (b) (4) and drug product. Moreover, no investigation was included in the qualification report regarding the failure of producing valid test results for (b) (4) for the working (b) (4) reference standard.
- 5
Inadequate investigation of critical AQL defect
DEV-003-2024-0049 detected on January 29, 2024 indicated a critical defect, (b) (4) (b) (4) was observed during AQL of (b) (4), batch (b) (4). Your firm failed to fully investigate and implement an effective corrective action/preventative action after identifying (b) (4) of (b) (4) for (b) (4) contributed to this critical defect.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3020223359, newest first.
- Form 483, January 2026FDA record date Jan 30, 2026 · Posted Oct 26, 2026
- Form 483, April 2022Inspection ended Apr 19, 2022 · Posted Oct 26, 2026VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.