Investigations and out-of-specification results in FDA Form 483 observations

How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
231
Each quoted below
Form 483s
161
Posted by FDA
Facilities
150
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 67 in 2026

Investigations and OOS results observations in Form 483s by inspection year
YearObservations
20101
20110
20123
20131
20141
20153
20169
201712
201812
201917
20202
202111
202220
202321
202416
202535
202667

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.192

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 231 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 1

    … e) Your firm lacked a disqualification and re-qualification program for as [illegible] of batches or out-of-specification environmental sampling results are reported. (f) (partial line in original unreadable) (b)(4) inappropriate 10 mg/mL multidose 5 mL vials, lot # J13-15MCPL failed sterility testing. The previous media fill performed [illegible] not representative of current practices. However, no action [illegible] performing aseptic …

    Contains “out of specification”Read the Form 483 →

  2. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 5

    5. Any unexplained discrepancy or the failure of a batch and specifications shall be thoroughly investigated, whether [illegible] Specifcally, A. Your firm failed to establish and follow an Out of Specification (OOS) Procedure to conduct investigations when an OOS result were received by your [lab]. a) OOS for high potency 124.2% (spec.) (b)(4) sterile product, MIC+B1 225/50/50 + 1 mg/mL multidose 30 mL vials, lot of (b)(4) vials on 9/16/15 for …

    Contains “unexplained discrepanc*”Read the Form 483 →

  3. Zhejiang Medicine Co.Inspection ended Jun 18, 2015 · FEI 3003631275 · Observation 1

    … between the trial and official results, including sample results that appear to include unknown peaks, which may cause the batches to be considered out-of-specification. However, due to the lack of supporting raw data (e.g. sample weights/dilutions), an accurate calculation of the residual solvent levels was not possible. Notably, your firm has initiated a total of 1 OOS investigation (including raw materials, in-process and finished products) …

    Contains “out of specification”Read the Form 483 →

  4. Zhejiang Medicine Co.Inspection ended Jun 18, 2015 · FEI 3003631275 · Observation 3

    OBSERVATION 3 Deviations from critical control points are not investigated. Specifically, from 01/2013 to 08/2013, your firm initiated a total of 7 deviation investigations regarding Be © excursions during Oot API. This limit is considered a critical control point. Our review of the 7th deviation found that your tirm had concluded no further deviation investigations were necessary regarding excursions during “ue to a historical data review …

    Contains “not … investigated”Read the Form 483 →

  5. Zhejiang Medicine Co.Inspection ended Jun 18, 2015 · FEI 3003631275 · Observation 6

    OBSERVATION 6 Critical control parameters are not adequately monitored and controlled. Specifically, . (0) (4) A) Our review of restored ©“ data for Batch No. © found that the run parameters including ©@and| ~~ ®@were not recorded for the time period from 13:28:37 to 15:08:37, May 29, 2015. No deviation was documented; no root cause was identified, and no investigation was conducted. B) During this © “process, there were 20 alarms generated …

    Contains “root cause*”Read the Form 483 →

  6. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 9

    Any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has already been distributed. Lot number 0806121600 of Heparin 5000 Units/L NS was tested on 08/14/12 and found to be "Not Sterile" at Day 0. There was no investigation conducted to determine the cause and impact of this result.

    Contains “unexplained discrepanc*”Read the Form 483 →

  7. Village Fertility Pharmacy, Inc.Inspection ended Mar 13, 2013 · FEI 3008335877 · Observation 2

    The firm failed to adequately evaluate product integrity incident reports, received from patients and healthcare practitioners, for injectable Progesterone produced in various solutions (e.g. sesame oil and ethyl oleate). Neither root-cause analysis nor corrective/preventive actions were identified or documented by the firm to avoid future occurrences of the incidents. For example: A. Two different incident reports were received for Progesterone …

    Contains “root cause*”Read the Form 483 →

  8. Boston Analytical, Inc.Inspection ended Nov 9, 2012 · FEI 1221426 · Observation 1

    Written production and process control procedures are not followed in the execution of production and process control functions. Specifically, the following SOPs were not followed: a.) SOP P-1050, Version 16 Laboratory Investigation Policy, states all unexpected, out of trend or out of specification results are to be investigated however this was not followed for the following samples analyzed: * Monosodium Glutamate Project #(b)(4), Sample …

    Contains “out of trend”Read the Form 483 →

  9. ARL Biopharma, Inc. dba Analytical Research LaboratoriesInspection ended Nov 8, 2012 · FEI 3003644883 · Observation 4

    4. Your firm has had 13 confirmed endotoxin failures for various drug products from October 2010-October 2012. There is no documentation of any investigations conducted into any endotoxin failures, including the failure of sample #186077-01 of Sodium Bicarbonate 150mEq/1000mL in Sterile Water for Injection that was submitted by NECC. SOP MBI-126 Microbiology Out-of-Specification Investigation (OOS), does not address investigation of OOS’s for …

    Contains “out of specification”Read the Form 483 →

  10. Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 2

    Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy. Specifically, 1. Since March 2012 your firm has discovered 2 lots [illegible] of Fentanyl Citrate for injection which failed HPLC stability time point analysis for total impurities. Subsequent investigation of the failures [illegible] were due to extractables from the rubber plunger. In …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  11. Regeneron Pharmaceuticals, Inc.Inspection ended Mar 31, 2010 · FEI 1000514603 · Observation 1

    … WFI supply to those specific equipments: The firm failed to conduct a comprehensive investigation of the WFI system in building [illegible] to determine the root cause/source. The firm enlisted the services of a contract firm to conduct a sanitization and passivation of the system, however, there was no comprehensive investigation to examine system design, work order histories and other system related information which may have identified …

    Contains “root cause*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about investigations and OOS results in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.