Regeneron Pharmaceuticals, Inc. Form 483, March 2010

FDA issued this Form 483 to Regeneron Pharmaceuticals, Inc. in Rensselaer, New York (FEI 1000514603) at the end of a drug inspection that ended March 31, 2010. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 31, 2010
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jan 17, 2024
5,040 days after the inspection
Facility
FEI 1000514603
Rensselaer, New York

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    WFI failures without comprehensive root cause investigation

    Following a number of failing "clean hold validation studies" for multiple equipments based on [illegible] which did not meet acceptance criteria and which were concluded to be [illegible] burden endotoxin results related to the WFI supply to those specific equipments: The firm failed to conduct a comprehensive investigation of the WFI system in building [illegible] to determine the root cause/source. The firm enlisted the services of a contract firm to conduct a sanitization and passivation of the system, however, there was no comprehensive investigation to examine system design, work order histories and other system related information which may have identified contributing factor(s)/underlying cause of the WFI-related failures.

  2. 2

    Uncontrolled blank worksheets in raw material lab

    There are no security measures employed [illegible] the issuance of worksheets in the raw material testing laboratory located in building II. Inspection found that it is possible to [illegible] additional uncontrolled blank worksheets.

  3. 3

    SCAR log entries not closed out

    Review of the firm's manual log for SCARs (Supplier Corrective Action Requests) which was stated to be the original GMP document for tracking these events found numerous entries for the past two years which were not closed out. This log is used for tracking of potential quality issues related to raw materials received from vendors.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.