Skip to content

Investigations and out-of-specification results in FDA Form 483 observations

How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
231
Each quoted below
Form 483s
161
Posted by FDA
Facilities
150
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 67 in 2026

Investigations and OOS results observations in Form 483s by inspection year
YearObservations
20101
20110
20123
20131
20141
20153
20169
201712
201812
201917
20202
202111
202220
202321
202416
202535
202667

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.192

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 231 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 2

    There is a failure to thoroughly review a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Change Control PR1257198, opened on 6-Dec-2017 and closed on 21-Sep-2018, did not include a sufficient assessment on (b) (4) a critical material, used for manufacturing of Gammagard Liquid (GGL) and HyQvia. (b) (4) (item code (b) (4)) is used in the (b) (4), (b) (4), (b) (4) (b) (4) and …

    Contains “thoroughly review*”Read the Form 483 →

  2. Torrent Pharmaceuticals LimitedInspection ended Apr 16, 2019 · FEI 3005029956 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, The summary of OOS investigations conducted by the firm during the period beginning from January 2017 to March 2019 is as follows: 2017 to 2019 Valid Invalid % Invalid Finished Product 340* 93 247 73% Stability 203* 80 123 61% …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  3. Torrent Pharmaceuticals LimitedInspection ended Apr 16, 2019 · FEI 3005029956 · Observation 2

    … All process validation batches were rejected as summarized below: Strength (b)(4) mg (b)(4) mg Total PV batches 4 3 Total OOS investigations 6 3 Batch Disposition All rejected All rejected (A) Process Validation for (b)(4) Tablets USP (b)(4) mg The following OOS investigations were initiated during testing of process validation batches: OOS No. OOS/IN/F/FP/16/257 OOS/IN/F/FP/16/137 Date of Initiation 9/29/16 7/23/16 Batch #(b)(4) PV Number 1 1 1 …

    Contains “OOS”Read the Form 483 →

  4. Torrent Pharmaceuticals LimitedInspection ended Apr 16, 2019 · FEI 3005029956 · Observation 4

    Out of Specification Investigation for API products is deficient. Specifically, OOS Investigation Number OOS/IN/A/ST/17/013 for (b)(4) pertaining to batch number (b)(4), was initiated on 03/06/17 to probe the following OOS results generated during Assay testing at the 12M time point (25°C/60%RH and 30°C/75%RH): 25°C/60%RH: (b)(4)% 30°C/75%RH: % Note: Specification is NLT (b)% and NMT (b)(4)% (on Anhydrous basis) As part of hypothesis (Phase I), a …

    Contains “out of specification”Read the Form 483 →

  5. Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 2

    Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, the following out-of-specification potency results were observed: • T3 6mcg capsules S/R, lot #01082019@9, Liothyronine Sodium (T3) potency: 86.3%; • T3 20mcg capsules S/R, lot #01252019@7, Liothyronine Sodium (T3) potency: 116%; • T3 30mcg, lot #01252019@14, Liothyronine …

    Contains “out of specification”Read the Form 483 →

  6. Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 5

    Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, pressure differential readings for (b) (4), which monitors the pressure from the ISO 7 Hazardous Prep Room to the ISO 8 Non-Hazardous Prep/Buffer Room (established negative pressure differential limit (b) (4)), were out of specification on 1/14/19 to 1/15/19, all of December 2018, and 11/1/18 to 11/27/18. Mixing of …

    Contains “out of specification”Read the Form 483 →

  7. Lupin LimitedInspection ended Feb 8, 2019 · FEI 3004819820 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, 1. The firm's procedure CQA-004-17 “Handling of out of Specification test results” Section 5.1.12 (a) states — ‘Retesting shall be done by BE analysis following the approved laboratory procedure preferably by original analyst …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  8. Sun Pharmaceutical Medicare LimitedInspection ended Feb 5, 2019 · FEI 3002957541 · Observation 1

    OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your firm has invalidated Out-of-Specification (OOS) results obtained during re-dispersibility tests attributing to human error as summarized below: a) Investigation, PR ID 141361 was initiated on 12-OCT-2018 when …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  9. Daiichi Sankyo Chemical Pharma Co., Ltd.Inspection ended Jan 25, 2019 · FEI 3003279188 · Observation 4

    Written records of investigations into unexplained discrepancies are not always fully investigated. Specifically, Deviation investigations do not always extend to other processes that may have been associated with the specific failure or discrepancy and contain a conclusion and follow-up. Examples: 1) Deviation Number TPACD2017-001 - A glass ^(b) (4) fragment was collected in a strainer of a liquid delivery pipe in the ^(b) (4) production …

    Contains “unexplained discrepanc*”Read the Form 483 →

  10. Dishman Carbogen Amcis Ltd.Inspection ended Oct 26, 2018 · FEI 3004161218 · Observation 1

    PRODUCTION SYSTEM 1.) Blending of in-specification with out-of-specification (OOS) intermediate batches is performed. Specifically, [illegible]. (intermediate) batch tested OOS for impurity. The batch was manufactured starting on 3/05/2018. QC testing of this batch yielded a result of [illegible]% for the impurity against a specification of less than or equal to [illegible]%. Deviation investigation Dv [illegible] 1801, written for this incident, …

    Contains “out of specification”Read the Form 483 →

  11. Dishman Carbogen Amcis Ltd.Inspection ended Oct 26, 2018 · FEI 3004161218 · Observation 2

    LABORATORY CONTROL SYSTEM 2.) Laboratory investigations for OOS intermediate batches are not conducted. Specifically, according to SOP BDQC-311 for OOS investigations (effective 07/16/2018), OOS is to be conducted on "...all quantitative and qualitative tests of...intermediates..." An investigation of an OOS impurity result in the [illegible] intermediate batch or [illegible] was not conducted.

    Contains “OOS”Read the Form 483 →

  12. Cipla LimitedInspection ended Sep 28, 2018 · FEI 3004081307 · Observation 2

    Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, A change to production instructions was implemented prior to completion of all corrective action changes related with a deviation. Namely, as part of Deviation DEV-1006-2017-00073 for [illegible] Tablets, USP [illegible] mg lot [illegible] (AQL non-compliance for minor defects). A Remedial Action item was initiated …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  13. Unichem Laboratories Ltd.Inspection ended Jul 27, 2018 · FEI 3006456888 · Observation 2

    … The peak matching Related Compound location in the sample sets [illegible] calculates to be approximately 0.3%, which would be Out Of Specification (OOS). The required investigation and reconciliation by Quality Assurance was not performed for this occurrence of an OOS event. Further review of Unichem Laboratories Ltd. procedure PPQC141/00, confirmed the company has a policy permitting any response attributed to a blank in HPLC analysis to be …

    Contains “out of specification”Read the Form 483 →

  14. Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 6

    … In addition, your firm identified the open hose connections as the root cause for the out-of-specification bioburden result for [illegible] load, lot# [illegible], documented in Deviation DE-P2-17-167.

    Contains “root cause*”Read the Form 483 →

  15. FH Investments Inc. dba Asteria HealthInspection ended Jul 10, 2018 · FEI 3010348724 · Observation 4

    There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has already been distributed. Specifically, the assessment of the investigation into the assay failure of an Estradiol 6 mg Pellet, Lot04252017@3, at the (b) (4) time-point lacks evidence to support invalidation of the out-of-specification (OOS) result.

    Contains “thoroughly review*”Read the Form 483 →

  16. Glenmark Pharmaceuticals Ltd.Inspection ended May 24, 2018 · FEI 3008565058 · Observation 3

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, e Your firm's QC unit did not investigate in to the issues of API peak seen in the blank injections during method validation for related substances by HPLC method. Additionally, system suitability (precision) standard injections (| ppm) peaks were not integrated A The reintegration of these peaks changed the …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  17. Plasma Industries Belgium SCRLInspection ended Mar 16, 2018 · FEI 3003208230 · Observation 2

    … Investigation failed to address the root cause for plasma overflow into the (b)(4) B. Event 104972 which was opened due to the detection of particles during the changing of (b)(4) was opened on 22-Nov-2017 however the date detected was 22-Sep-2017. This deviation was still open during the current inspection. C. Event 105703 which was opened due to the detection of particles on (b)(4) was opened on 05-Dec-2017 however the date detected was …

    Contains “root cause*”Read the Form 483 →

  18. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 8

    … An investigation was not conducted and a root cause was not determined. b. (b)(4) surface sampling is part of the firm's Environmental Monitoring program. Surface samples are taken with (b)(4), immediately after spraying sterile (b)(4) on the surface.

    Contains “root cause*”Read the Form 483 →

  19. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 10

    … Your firm conducted an inadequate Sterility OOS investigation. Review of OOS Sterility failure investigation revealed Bacillus species was detected in (b)(4). The firm's corrective action includes cleaning and disinfecting the controlled environment (b)(4) times. Demonstration of the effectiveness of the cleaning operations was not assessed because environmental and personnel monitoring was not performed afterward.

    Contains “OOS”Read the Form 483 →

  20. Suven Life Sciences Ltd.Inspection ended Feb 15, 2018 · FEI 1000623515 · Observation 7

    Your firm's Product Quality Reviews (PQRs) are deficient. Specifically, A. 2017 PQR for (b) (4) Capsules (review period January 2016 - December 2017): 1. Does not address corrective and preventative actions implemented for out of specification (OOS16-005) for (b) (4) content for (b) (4) Capsules (b) (4) mg, Batch #(b) (4) 2. Is missing change control (EN/CCP/17/5036) for the installation of new equipment in the packing line ((b) (4) Inserting …

    Contains “out of specification”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about investigations and OOS results in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.