Investigations and out-of-specification results in FDA Form 483 observations
How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 231
- Each quoted below
- Form 483s
- 161
- Posted by FDA
- Facilities
- 150
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 67 in 2026
| Year | Observations |
|---|---|
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 1 |
| 2015 | 3 |
| 2016 | 9 |
| 2017 | 12 |
| 2018 | 12 |
| 2019 | 17 |
| 2020 | 2 |
| 2021 | 11 |
| 2022 | 20 |
| 2023 | 21 |
| 2024 | 16 |
| 2025 | 35 |
| 2026 | 67 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 231 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 3
… Examples active and settle plates from roo nishinomyaensis, Staphylococcus haem pathogen recoveries from the Grade C area are not investigated unless alert and action levels are observed. Furthermore, integrity [illegible] misused by aseptic filling operators. The rationale for not 6) Viable monitoring selection for Grade C filling "FT9PRPQP087-00", effective December 22, 2021, during media fill simulation for viable monitoring: H. Human-Machine …
Contains “not … investigated”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 7
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, investigations into atypical recoveries Microbiology Head of Department, investigations recoveries. Per your "Microbial Identification Program", objectionable microorganism will be investigated. recoveries in the Grade C area are not investigated. The where is located: Gardnerella vaginalis, Past pneumotropica, …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
People's Custom Rx and Clinical Care, LLCInspection ended Aug 5, 2021 · FEI 3003780900 · Observation 2
… The firm has no alarm system that would signal if room pressures were out of specification. Pressure differential values are only recorded (b) (4).
Contains “out of specification”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 4
… Revision 09, Effective Date: 02 Apr 2020 allow equipment recleaning if a swab sample result failed to meet the acceptance criteria without conducting a root cause investigation. An investigation is only required if the swab sample result failed after the recleaning. c. TOC recovery and degradation studies documented in CV218Recovery.00: Evaluation of Soil Recovery of Molecule (b) Approved 03/20/2019, were inadequate. On 04/16/2021, Scientist II, …
Contains “root cause*”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 5
Discrepancies are not fully investigated to identify a root cause and corrective and preventative actions (CAPA) are not adequately implemented to prevent recurrence. Specifically, a. Excursions occurred during product validation are investigated as protocol events under FDBU-SOP-0457: Execution and Review of Qualification and Validation Documents. Section 4.6.7.1.2 states that if there is potential or unknown product impact, QA is consulted for …
Contains “not … investigated”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 6
Microbial control of the facility is inadequate. EM excursions were not investigated for root cause and CAPAS implemented were inadequate to control microbial contamination. Specifically, a. (b) (4) environmental and water monitoring summary reports from 2020 documented 30 events of action level Paenibacillus spp. (mostly P. glucanolyticus) recoveries from 57 monitoring sites, 5 events of alert/action level Burkholderia recoveries from 6 …
Contains “not … investigated”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 1
Failure to conduct thorough investigations into unexplained discrepancies. Specifically, a. The cross-contamination of client (b) (4) viral vaccine drug substance batch (b) (4), which was manufactured between (b) (4) and (b) (4), with the virus from client (b) (4) as described in deviation 3100012112 initiated on 3/17/2021 has not been thoroughly investigated. Specifically, i. The deviation did not include consideration of operator (b) (6) who is …
Contains “unexplained discrepanc*”Read the Form 483 →
Wuxi BiologicsInspection ended Apr 2, 2021 · FEI 3010606982 · Observation 6
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Complaint Investigation CI-19-001 was initiated on 03/15/2019, after a product complaint was submitted for a potential low fill vial of (b) (4) Lot (b) (4) The complaint investigation performed included an evaluation of the …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1
(REPEAT OBSERVATION) There is a failure to thoroughly review any unexplained discrepancy, the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) During the review of Adverse Event Investigation ADE2020081 and associated batch record for Dexamethasone/Moxifloxacin, 1/5 mg/ml, PF Injectable solution, lot #(b) (4) it was discovered that the product lot …
Contains “thoroughly review*”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 2
… In addition, the firm rejected the (b) (4) PV batch (b) (4) when potency values (for Prednisolone Acetate) were found OOS for samples representing (b) (4) the batch. The resulting OOS investigation concluded that the lower amount of bulk suspension left over for this batch (i.e. (b) (4) ml) contributed to the lower potency results. However, the firm failed to scientifically explain how the (b) (4) PV lot (b) (4) that has a comparatively similar …
Contains “OOS”Read the Form 483 →
Millers of Wyckoff, IncInspection ended Oct 9, 2020 · FEI 3004600183 · Observation 2
… In this instance, the report recorded the differential pressure reading was out of specification. However, you continued to use this room as well as adjacent cleanrooms for production of sterile drug products. In addition, on 09/25/2020, I observed that the Magnahelic equipment used to monitor the differential reading for the Hazardous Room was (negative) -0.11" w.c., which was not within specifications.
Contains “out of specification”Read the Form 483 →
OSO BioPharmaceuticals Manufacturing, LLCInspection ended Mar 20, 2020 · FEI 1643045 · Observation 2
OBSERVATION 2 Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. For example: a) Investigations for dead insects found in manufacturing areas continues without verification that actions to prevent bugs from entering production areas is accomplished. For example, Deviation Report June 2019 reported multiple dead moths found in reported a dead insect in Filling Room f<-'J_Deviation …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 2
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, on April 5, 2019, you were notified of a confirmed potency failure for Vasopressin 0.4 units/ml in 0.9% NaCl [illegible] bag at the 50-day timepoint for beyond use dating (BUD) by your contract testing laboratory. You assigned …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 1
Laboratory controls do not always include the establishment of scientifically sound and appropriate procedures designed to assure that drug substances conform to appropriate standards of identity, strength, quality and purity. Specifically, when there is no scientific basis found for invalidating initial out-of-specification (OOS) API test results and no assignable cause for the OOS is determined, procedures (pZQA005) allow re-testing (following …
Contains “invalidat*”Read the Form 483 →
Ajinomoto Althea, Inc.Inspection ended Aug 7, 2019 · FEI 3004575449 · Observation 1
… The firm's investigation into these particulates ultimately determined the root cause to be associated with corroded (D)-(4) within connectors used to connect the (D)-(4) drug product vessel to the (D)-(4) set up and/or filling line. Drug product lots produced during this time were not always rejected.
Contains “root cause*”Read the Form 483 →
Ajinomoto Althea, Inc.Inspection ended Aug 7, 2019 · FEI 3004575449 · Observation 2
OBSERVATION 2 Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure. Specifically, The firm's investigation SOP-0980, Rev 000, "Conducting cGMP Investigations" states in section 7.3.1.2 to assess the impact on other processes, procedures, …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 1
1. Investigations into out-of-specification (OOS) QC analytical results, related to finished API product quality failures, are not adequate. Specifically, your investigations do not always determine root causes for API drug substance failures. Review of several OOS investigations revealed that your personnel conducting the investigations are not always adequately assessing the analytical data to evaluate/eliminate all possible sources of the OOS …
Contains “out of specification”Read the Form 483 →
Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 2
… Note that during the inspection we observed several OOS events for APIs (0) (4) and (0) (4) where ® ©) is used as the key starting material for both APIs. b) The equipment used in the manufacture (®)@) steps) of your APIs and API intermediates is manually monitored for temperature during that particular stage of manufacturing, by having the production operator read the temperature on the display and record in the batch record. However, review of …
Contains “OOS”Read the Form 483 →
Cipla Ltd. Virgonagar SiteInspection ended Jul 19, 2019 · FEI 3002806691 · Observation 5
… Note that your firm has several confirmed OOS failures for long-term stability at 30 +/-2 C and ®) +/- 5% R.H., which have been attributed to "exposure to atmosphere and heat, undergoes colour change, hence material by nature is not stable at higher temperature beyond 12 months at any temperature exceeding 25 C."
Contains “OOS”Read the Form 483 →
Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 1
… The root cause was determined on February 22, 2019 and a BPDR was submitted to FDA on April 4, 2019. b) On June 10, 2018, a discrepancy was observed by an analyst between the limit recorded in the (b) (4) system and the SOP LE12QC2102/SOP-048719 for the microbial testing of the (b) (4) used for grade (b) (4) interventions and setup of the (b) (4) line by the aseptic (b) (4) operator. The introduction of the (b) (4) (b) (4) and (b) (4) testing …
Contains “root cause*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.192Production record reviewIn this theme's rule56
- 21 CFR 211.113Control of microbiological contamination9
- 21 CFR 211.22Responsibilities of quality control unit8
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.194Laboratory records4
- 21 CFR 211.166Stability testing3
- 21 CFR 211.42Design and construction features2
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.160General requirements2
- 21 CFR 606.100Standard operating procedures2
Ask FDAgent about investigations and OOS results in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.