Baxalta Belgium Manufacturing SA

Boulevard Rene Branquart 80, Lessines, Belgium

FEI 3002806503DUNS 370634700

Company: Baxalta US Inc. · Linked by exact D-U-N-S match (079887619) in FDA registration data

FDA has 7 inspections on file for Baxalta Belgium Manufacturing SA in Lessines, Belgium (FEI 3002806503), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Four of the five FOIA requests for this site have asked FDA for this inspection's 483.

The most recent OAI inspection ended on Jan 21, 2011. FDA issued a warning letter on (CBER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant, Baxalta US Inc. (D-U-N-S 079887619), has registered 14 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2009–2024
2 OAI · 4 VAI · 1 NAI
Inspections with 483 observations shown
2 of 7
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest Oct 1, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Identification of Equipment and Lines

      The batch production and control records are deficient in that they do not include the identity of major equipment used.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate computer input-output verification controls

      Input to and output from the computer or related system of formulas or other records or data shall be checked for accuracy. The degree of input/output verification was not sufficiently based on the complexity and reliability of the computer or related system. Specifically, a) Process Change PR1314817, implemented on 10Aug2018, was initiated to secure the (b) (4) step, by limiting settings ((b) (4)). This change, PR1314817, was implemented to avoid sudden (b) (4) by limiting the increase of the (b) (4) and decreasing the (b) (4) (b) (4) (b) (4), according to the (b) (4) of the system. As a result of an unexpected (b) (4) modification, this process change was unintentionally applied to the (b) (4) sequence of the (b) (4) of the (b) (4) which led to a deviation to the routine (b) (4) sequence, as the (b) (4) modulating (b) (4) remained (b) (4) during the (b) (4) sequence. This caused inappropriate (b) (4) from (b) (4) to the (b) (4) Tank. Since December 2018, a (b) (4) trend for endotoxins (LAL) for the (b) (4) sample ((b) (4) (b) (4)) and for the Final Container samples were observed. The (b) (4) trend for endotoxins was detected on (b) (4) Line (b) (4) used for the manufacture of Gammagard Liquid, HyQvia, and Cuvitru, and involved (b) (4) bulk lots. The root cause was determined on February 22, 2019 and a BPDR was submitted to FDA on April 4, 2019. b) On June 10, 2018, a discrepancy was observed by an analyst between the limit recorded in the (b) (4) system and the SOP LE12QC2102/SOP-048719 for the microbial testing of the (b) (4) used for grade (b) (4) interventions and setup of the (b) (4) line by the aseptic (b) (4) operator. The introduction of the (b) (4) (b) (4) and (b) (4) testing positions, which corresponds to the (b) (4) and the (b) (4) respectively) took place in 2009. A retrospective review found that two results were not identified as being Out of Limit during the (b) (4) of Gammagard Liquid lot (b) (4) and (b) (4) sublot (b) (4) ((b) (4)); and Gammagard Liquid lot (b) (4) ((b) (4)). Both test results were at (b) (4) (b) (4)). The Gammagard Liquid lot (b) (4) (expiration date June 24, 2020) and (b) (4) sublot (b) (4) (expiration date June 24, 2020) were distributed in the US market. A Biological Product Deviation Report was submitted to the FDA on July 20, 2018 (tracking number: 2018-058). The limit in the (b) (4) was corrected on June 29, 2018 (Deviation PR1308695).

    2. Observation 2

      Incomplete change control assessment for critical material

      There is a failure to thoroughly review a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Change Control PR1257198, opened on 6-Dec-2017 and closed on 21-Sep-2018, did not include a sufficient assessment on (b) (4) a critical material, used for manufacturing of Gammagard Liquid (GGL) and HyQvia. (b) (4) (item code (b) (4)) is used in the (b) (4), (b) (4), (b) (4) (b) (4) and (b) (4) (b) (4) steps. Specifically, Change Control PR1252801 was opened on 17-Nov-2017 (closed on 23-Jan-2018) to remove the (b) (4) code from the Bulk Drug Substance (BDS) Bill of Materials (BOM) and for use of an alternative (b) (4) source of (b) (4) ((b) (4)). After implementation of this corrective action, final container lots were produced with (b) (4) levels of rejects due to (b) (4) Change Control Record PR1257198, closed on 21 September 2018, documented a decision to use the (b) (4) (b) (4) as a backup of the (b) (4) for the manufacture of Gammagard Liquid and HyQvia. Since early 2019, an increased level of visible (b) (4) was observed again during the (b) (4) visual inspection for Gammagard Liquid and HyQvia lots manufactured using (b) (4) from the (b) (4). The (b) (4) were identified as (b) (4) A possible root cause was determined to be related to the implementation of the (b) (4) configuration. As a preventive action, the (b) (4) was replaced by the (b) (4) (b) (4) for manufacture of Gammagard Liquid and HyQvia on April 30, 2019. This investigation is ongoing.

    Show observations 3 to 6
    1. Observation 3

      Late BPDR filing for broken vial complaints

      Four non-medical broken vial US complaints for Gammagard Liquid were discovered in April, May 2017 and were not submitted as BPDRs until February 13, 2018. Specifically, a) PR1194575, dated 03April2017, reported 3 leaking damaged vials of Gammagard Liquid (10%, 10g, US). b) PR1198237, dated 20April2017, reported customer received one Gammagard Liquid (10%, 10g, US) broken vial. c) PR1205477, dated 24May2017, reported one Gammagard Liquid (10%, 30g, US) leaking/broken vial. d) PR1243345, dated 10Oct2017, reported one Gammagard Liquid (10%, 30g, US) broken vial. These complaints were reported as one BPDR 2017-042, 049, 068, 142 on February 13, 2018, which exceeded the 45 Day Calendar limit.

    2. Observation 4

      Late serious adverse event reporting

      The following Serious Unexpected Adverse Events were submitted in excess of 50 Calendar Days, which is > 15 Calendar Day post marketing reporting requirement. Specifically, a) Gammagard S/D- 4 Serious Unexpected Adverse Events- Avg. Reporting Time- 224 Days b) Cuvitru- 8 Serious Unexpected Adverse Events-Avg. Reporting Time- 169 Days c) HyQvia- 8 Serious Unexpected Adverse Events-Avg. Reporting Time-115 Days d) Gammagard Liquid-11 Serious Unexpected Adverse Events-Avg. Reporting Time- 301 Days

    3. Observation 5

      Adverse event quality investigations not performed

      Quality Investigations were not conducted per SOP-2024-Adverse Event Quality Investigations, dated March 23, 2018 for the following reported viral transmission and fungal infection events. The causality assessment in each case was assessed as possible by the company/manufacturer, and the lot numbers were known. Specifically, a) Suspect Adverse Reaction Report, Case (b) (4), dated (b) (4), Gammagard Liquid Immunoglobulin, Lot (b) (4), reported fungal infection. The company comment assessed the event of Fungal infection as possibly related to Gammagard Liquid. b) Suspect Adverse Reaction Report, Case (b) (4), dated (b) (4), Gammagard Liquid Immunoglobulin, Lot (b) (4), reported that patient contracted Hepatitis B from Gammagard Liquid (was negative 3 years ago). The company causality assessment assessed the event Hepatitis B as possibly related to Gammagard Liquid. c) Suspect Adverse Reaction Report, Case (b) (4), dated (b) (4), Gammagard Liquid Immunoglobulin, reported Hepatitis C in a patient. Several Lots but not limited to: (b) (4) (b) (4) were used from 6Oct2016 to 25May2017. The company comment assessed the event Hepatitis C as possibly related to Gammagard Liquid. Minimal investigational activities specified in SOP-2024, Adverse Event Quality Investigations, 23Mar2018, included a review of the following: batch records, events during production, product release testing results (including sterility), environmental and bioburden testing results, pre and post filter integrity results, visual inspection of retention samples (where applicable), stability review, and NAT/PCR and/or serology testing.

    4. Observation 6

      Inappropriate facility design for cleaning maintenance

      The Room (b) (4) and Room (b) (4) is not of appropriate design for its intended use and for its cleaning and maintenance. Specifically, a) The design of the (b) (4), (b) (4) Room (b) (4) has an unused portion of (b) (4) of almost (b) (4) in length, where (b) (4) is the (b) (4) of the (b) (4). b) The design of the (b) (4), (b) (4) Room (b) (4) has an unused portion of (b) (4) of almost (b) (4) in length, where (b) (4) is the (b) (4) of the (b) (4). These Points of Use are used for cleaning (b) (4) for Gammagard Liquid, Cuvitru, and HyQvia in the (b) (4) area.

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  4. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood ProductsCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Oct 1, 2025. Each one asked for a Form 483.

  • Inspection ending Nov 22, 2024VAI

    4 requests. In the inspection history above. FDA has posted its Form 483.

    1. Oct 1, 2025FDA-FOIA-2025-11495Form 483Records released
    2. Jul 22, 2025FDA-FOIA-2025-8905Form 483Closed
    3. Jul 22, 2025FDA-FOIA-2025-8900Form 483Closed
    4. Dec 13, 2024FDA-FOIA-2024-10997Form 483Records released
  • Inspection ending May 31, 2019VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jan 31, 2024FDA-FOIA-2024-1054Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 7 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCBER · BiologicsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Baxalta US Inc.D-U-N-S 079887619

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Baxalta US Inc. (D-U-N-S 079887619) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Takeda Manufacturing Austria AGVienna, Austria · FEI 30028071338 inspections8latestJul 17, 2026NAINone on file
  • Takeda Manufacturing Austria AGOrth An Der Donau, Austria · FEI 30030465653 inspections3latestMay 18, 2026NAINone on file
  • BAXALTA US INC.Round Lake, Illinois · FEI 30123859693 inspections3latestNov 26, 2025VAINone on file
  • BAXALTA US INC.Los Angeles, California · FEI 20110219 inspections9latestNov 7, 2025NAINone on file
  • Takeda Manufacturing Singapore Pte. Ltd.Singapore, Singapore · FEI 30091536544 inspections4latestAug 15, 2025VAINone on file
  • Baxalta US Inc.Social Circle, Georgia · FEI 30139804492 inspections2latestJan 30, 2025NAINone on file
  • Takeda Manufacturing Italia SPACittaducale, Italy · FEI 30072441315 inspections5latestNov 12, 2024VAINone on file
  • Baxalta US Inc.Thousand Oaks, California · FEI 10005199656 inspections6latestApr 7, 2022VAINone on file
  • Baxalta Manufacturing SàrlNeuchatel, Switzerland · FEI 30026893894 inspections4latestNov 12, 2018VAINone on file
  • Baxalta US Inc.Van Nuys, California · FEI 30027725561 inspection1latestApr 16, 2009VAINone on file
  • Takeda Manufacturing Austria AGWIEN, Austria · FEI 3002669612Registered; no FDA inspection on file
  • Takeda Manufacturing Austria AGWien, Austria · FEI 3003608831Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002806503 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002806503. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.