Investigations and out-of-specification results in FDA Form 483 observations
How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 231
- Each quoted below
- Form 483s
- 161
- Posted by FDA
- Facilities
- 150
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 67 in 2026
| Year | Observations |
|---|---|
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 1 |
| 2015 | 3 |
| 2016 | 9 |
| 2017 | 12 |
| 2018 | 12 |
| 2019 | 17 |
| 2020 | 2 |
| 2021 | 11 |
| 2022 | 20 |
| 2023 | 21 |
| 2024 | 16 |
| 2025 | 35 |
| 2026 | 67 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 231 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 5
Corrective actions and preventive actions (CAPAs) to discrepancy or the failure of a batch or any of its components to meet any of its specifications are not always effectively verified to prevent recurrent deficiencies. The following repeated deviations with the same or similar root cause were reported. Specifically, A. Temperature control deviations for (b)(4) (TW#136473, dated 09 November 2020; TW#153413, dated 17 September 2021; TW#153881, …
Contains “root cause*”Read the Form 483 →
Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 6
Failure to adequately assure approved levels of measles neutralizing antibody in the final product. The Out of Specifications (OOS) results were not sufficiently investigated for the root cause. Specifically, A total of Measles OOS routine batches occurred to multiple Immune Globulin Final Container products within two aggregate period 1) from July to Sept 2019 and 2) from August to Sept 2022. The root cause was attributed to the (b)(4) materials …
Contains “OOS”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 1
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, a. On 11/16/2022, your Investigation Manager reviewed OOS/C/21/MDP/IPDP/002 that was initiated to probe an OOS result for a (b) (4) point (b) (4) uniformity (b) (4) assay test for (b) (4) suspension (b) (4) USP (b) (4) mg / (b) …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 2
… Some of the batches that shipped to the US market and are implicated with OOS results for (b) (4) uniformity assay, including but not limited to: OOS/C/20/MDP/FPDP/013 and OOS/C/20/MDP/SSDP/004. c. Your General Manager of Quality provided a list of (b) (4) manufacturing equipment in the (b) (4) Formulation. Of the (b) (4) manufacturing equipment, 33 are on SCADA (21 CFR Part 11 compliance), with the remaining manufacturing equipment that do not …
Contains “OOS”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 4
… procedures, batch manufacturing records (BMR), proposals for change controls & supporting data, APQR meant for review purposes, Draft investigation report of OOS, OOT, Market complaints, deviations, incidents etc., document copy as Change Control, Deviation, Temporary Change Control, Complaint, CAPA used for reference to auditors/visitors as well as draft trend analysis reports of OOS, OOT, Complaint, deviation, Environmental monitoring, (b) (4) …
Contains “OOS”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 9
Investigations are inadequate to determine the root cause for the failure of a batch of intermediate or API to meet specifications whether or not the batch has been already distributed. Specifically, On 11/21/2022, your Investigation Manager reviewed OOS/C/20/MDP/FPDS/007 that was initiated to probe OOS result that was reported in related substances test by HPLC during analysis of (b) (4) USP Batch No. (b) (4) such that the observed result of any …
Contains “root cause*”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 10
… Your investigations to find the root cause into the manufacturing process to address any deviations, OOS results, and OOT are inadequate e.g., you lack manufacturing data that are related to critical process parameters (CPP).
Contains “root cause*”Read the Form 483 →
QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 1
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A) No documented review was performed when mold was recovered on an operator (b) (4) plate sample taken on 06/29/2022 after ISO 5 operations in Clean Room (b) (4) and the clean room experienced elevated temperature and relative humidity excursions beyond the set alarm points. This mold recovery on 06/29 was the …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 1
Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. Specifically, A. Per various (b)(4) batch records, the Visible Particles USP <790> testing list a specification of "(b)(4) particles observed**If (b)(4) particle is observed during initial testing, test an additional (b)(4) vials with a …
Contains “thoroughly investigat*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 2
… Complaints were not adequately investigated to include an identification of the particle in the complaint sample. For example: 1. On 23 Mar 2021, a Customer Complaint #333544 reported black specks in four vials of (b)(4), lot# (b)(4). Four vials and four (b)(4) were returned to your firm for evaluation. The black specks were not analyzed in the lab. Retain samples review did not include an inspection for particles. 2. On 01 Feb 2021, a client …
Contains “not … investigated”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 5
… Your firm performed a Deviation Trending Investigation for Building (b)(4) on February 9, 2022 and determined the root cause to be the (b)(4) material was not robust enough to maintain integrity during use. Your firm initiated corrective action to remediate the issue to related (b)(4) integrity by opening a change control to switch to a (b)(4) mils thicker (b)(4) from the same (b)(4) manufacture. Your firm has since cancelled that change control …
Contains “root cause*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 10
… The root cause determined the validation requirements for layout, configuration and/or label orientation for LIMS labels in the (b)(4) are not qualified. The risk assessment for batch impact determined the labels achieve a (b)(4) log reduction (decontamination), and not the preferred (b)(4) log reduction. Action 552193 was initiated 6/28/22, to update A-WI-21-06-005-02 to label contact plates in the (b)(4) with marker instead of LIMS labels. The …
Contains “root cause*”Read the Form 483 →
AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 3
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) your firm received approximately 26 reports of adverse events related to your Testosterone and Estradiol implantable pellets, including reports of death, heart attack, stroke, and breast cancer. However, your firm's investigations into these complaints did …
Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →
Protherics UK Ltd.Inspection ended Jun 23, 2022 · FEI 3001417487 · Observation 1
… As a result, drug product results were invalidated and retested, due to a (b)(4) calibration test failure. For example, i). Quality Event 55795 - The (b)(4) calibration for the Quality Control (b)(4) was conducted per SOP (b)(4) entitled, "(b)(4) (b)(4)" on June 29, 2020, and failed the (b)(4) accuracy test during the calibration. Consequently, all CroFab and DigiFab (b)(4) drug product release tests that were performed (b)(4) (b)(4) were …
Contains “invalidat*”Read the Form 483 →
ID Biomedical Corporation of QuebecInspection ended May 20, 2022 · FEI 3004835647 · Observation 2
… The first investigation concluded "incorrect manipulation of the syringe during preparation for injection"; second investigation concluded most probable root cause of "mishandling by the healthcare professional"; and the third was a most probable cause "the defect (LLA crack) was originated in the LLA suppliers process". No "internal root cause at GSK level". A crack in the LLA (luer lock adaptor) on the syringe was confirmed by the supplier for …
Contains “root cause*”Read the Form 483 →
Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 6
… A throughput study was performed to investigate the root cause of the clogged [illegible] in deviations M11/01/22/04 and M23/08/21/01. The outcome of the study suggested that the current [illegible] configuration is [illegible] and therefore are recommended appropriate only for the (b)(4) step of the [illegible] used in the current number of [illegible] used) for the [illegible] of [illegible] is used (b)(4) process because the same bioreactor. …
Contains “root cause*”Read the Form 483 →
Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 10
… c) You do not perform complete investigations when an action level is reached to include root cause and corrective action. d) You do not have a system in place that allows for monitoring recurring [illegible] to identify repeated significant organism.
Contains “root cause*”Read the Form 483 →
Zhejiang Tianyu Pharmaceutical Co. Ltd.Inspection ended Mar 4, 2022 · FEI 3010972581 · Observation 2
OBSERVATION 2 (Quality System) There is a failure to thoroughly review any unexplained discrepancy or any of its components to meet any of its specifications shall be thoroughly investigated, whether or not the batch has been already distributed. Specifically, [illegible] for control of impurity evaluation during API process development establishes that impurity evaluation should be conducted before or after synthesis route is selected or …
Contains “thoroughly review*”Read the Form 483 →
Bioiberica, S.A.UInspection ended Feb 4, 2022 · FEI 1000418405 · Observation 5
Written records of investigations into unexplained discrepancies do not always include conclusions and follow-up which are adequately justified. Specifically, A. Investigations initiated and performed as a result [illegible] substance do not extend to batches manufactured during the campaign. B. During the inspection, I reviewed non-conformity investigations due to (b)(4) being blocked due to (b)(4) particle build. Your [illegible] which the …
Contains “unexplained discrepanc*”Read the Form 483 →
Engage Uni LLCInspection ended Nov 12, 2021 · FEI 3016249968 · Observation 1
Procedures for acceptance activities have not been adequately established. Specifically, Your firm's machining and finishing supplier for (b) (4), (b) (4), and (b) (4) failed to identify results of in-process inspection that deviated from the specifications documented on the inspection form, and these out of specification measurements were subsequently unidentified during DHR review conducted by your firm upon acceptance of finished devices. All …
Contains “out of specification”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.192Production record reviewIn this theme's rule56
- 21 CFR 211.113Control of microbiological contamination9
- 21 CFR 211.22Responsibilities of quality control unit8
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.194Laboratory records4
- 21 CFR 211.166Stability testing3
- 21 CFR 211.42Design and construction features2
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.160General requirements2
- 21 CFR 606.100Standard operating procedures2
Ask FDAgent about investigations and OOS results in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.