Wuxi Biologics Form 483, April 2021
FDA issued this Form 483 to Wuxi Biologics in Wuxi, China (FEI 3010606982) at the end of a drug inspection that ended April 2, 2021. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 15, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 2, 2021
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Mar 15, 2022
- 347 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate controls over computerized system changes
Appropriate controls are not exercised over computer systems or related systems to prevent changes to data. Specifically, per procedure WX-SOP-00154, entitled PAS (b) Batch Operation and Maintenance Procedure, Form WX-FORM-001141-03 is required to modify certain parameters in the Process Automation System (b) Batch (b) (4) system. While this document requires that QA approve the change, it does not require QA to verify the change(s) for accuracy once complete. In addition, although a second person verification of the change is required, this is not always performed. For example, on 02/08/2021 a request to change an alarm limit (e.g., Parameter 1970PIC101) in (b) (4) was submitted, approved by QA on 02/09/2021, and then implemented in (b) (4) However, a review of the modification application form revealed the signatures for the person who performed the alarm modification and the second verification were missing. On 03/22/2021, Deviation DV39507 for (b) (4) Lot (b) (4) was initiated after an issue occurred with alarm 1970PIC101 during the (b) (4) step. The investigation is on-going. This deviation required (b) (4) Lot (b) (4) be reprocessed.
- 2
Deficient Quality Unit oversight of controlled documents
The Quality Unit oversight over the issuance of controlled documents is deficient. Specifically, your Quality Assurance department does not have adequate controls established for the distribution and/or reconciliation of all quality forms issued to other departments. For example: a) On 03/22/2021, Form WX-FORM-000970-09, Registration Form of Samples for Analyses, was observed in the Quality Control laboratory. A review of your documentation controls revealed this controlled record is issued to Quality Control by your Quality Assurance department, however, there is not an adequate reconciliation plan in place. b) On 03/22/2021, Form WX-FORM-002218-02, Incoming Material Checklist, was observed in the Warehouse Management Office. A review of your documentation controls revealed this form is issued by the Warehouse Documentation group with no oversight from the Quality Assurance documentation group. As such, Quality Assurance has no control over the distribution and/or reconciliation of this form.
- 3
Inadequate preventive maintenance schedules for equipment
Adequate schedules have not been established for the preventative maintenance of equipment. Specifically, your firm failed to establish adequate preventative maintenance schedules for the following equipment: (b) (4) (MFG-UOE-3290), (b) (4) (MFG-DFC-3016), and (b) (4) (MFG-DFC-3017). For example, WX-SOP-00171, entitled Operation and Cleaning of Biologic (b) (4) Pump, states the (b) (4) of biologic (b) (4) pumps will be replaced (b) (4) In January 2021, a review of the preventative maintenance for the three (b) (4) mentioned was performed and identified to not be in agreement with the maintenance requirements specified in WX-SOP-00171. As such, the preventative maintenance schedules for the three (b) (4) were updated. However, a review of the preventative maintenance schedules identified the following issues: a) Although the preventative maintenance schedule for (b) (4) (MFG-UOE-3290) was updated in 01/2021 to require the (b) (4) replacement of the (b) (4) of the (b) (4) pump, in accordance with WX-SOP-00171. The PM due date was set for 07/06/2021. This PM schedule is inadequate as this (b) (4) has been in use since 03/30/2018 and the (b) (4) of the (b) (4) pump has never been replaced. b) Although the preventative maintenance schedule for the (b) (4) (MFG-DFC-3017) was updated in 01/2021 to require the (b) (4) replacement of the (b) (4) of the (b) (4) pump, in accordance with WX-SOP-00171. The PM due date was set for 07/31/2021. This PM schedule is inadequate as the last time the (b) (4) of the (b) (4) pump was replaced on this (b) (4) was 09/24/2019. c) Although the preventative maintenance schedule for the (b) (4) (MFG-DFC-3016) was updated in 01/2021 to require the (b) (4) replacement of the (b) (4) of the (b) (4) pump, in accordance with WX-SOP-00171. However, this PM update was incorrect as this (b) (4) does not contain (b) (4) pumps.
- 4
Deficient component sampling plans for chromatography media
The specifications established for components used in the production of drug substance are deficient in that they do not include a description of the sampling plan. Specifically, raw material specifications do not provide sufficient instructions to ensure samples collected are representative and reproducible. For example, the raw material specifications for (b) (4) chromatography media (Document WX-SPEC-000233), (b) (4) (Document WX-SPEC-000234), and (b) (4) (b) (4) media (Document WX-SPEC-000236), do not contain instructions requiring sampling operators to perform a (b) (4) of the material prior to collecting a sample. These materials are known to separate. These chromatography (b) (4) are used in the (b) (4) purification of (b) (4) drug substance.
- 5
Missing effectiveness checks for CAPAs
Effectiveness Checks for corrective and preventative actions implemented in response to a deviation investigations are not always initiated. Specifically, SOP WX-SOP-00422, Corrective Action and Preventative Action (CAPA) procedures states Effectiveness checks are required for action items involved in the non-conformance caused (e.g., deviations) unless a detailed and reasonable justification is provided. Deviations PR17464 was initiated to investigate events which resulted in the termination of (b) (4) batches, Lots (b) (4). The investigation resulted in several CAPAs including CAPA PR 19821. This CAPA was identified to be a risk mitigating, however, no effectiveness check was initiated to evaluate the effectiveness of the CAPA.
- 6
Inadequate complaint investigation of retention samples
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Complaint Investigation CI-19-001 was initiated on 03/15/2019, after a product complaint was submitted for a potential low fill vial of (b) (4) Lot (b) (4) The complaint investigation performed included an evaluation of the retention samples. However, no scientific rationale was provided to justify the visual inspection of only 11 of the (b) retention sample vials. In addition, SOP WX-SOP-00425, entitled Product Complaints, section 4.4.1.3, states to review retention samples and does not provide instructions for reviewing reduced amounts.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010606982, newest first.
- Form 483, May 2023FDA record date May 9, 2023 · Posted Mar 6, 2025
- Form 483, April 2019Inspection ended Apr 16, 2019 · Posted Mar 15, 2022VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.