Unichem Laboratories Ltd. Form 483, July 2018
FDA issued this Form 483 to Unichem Laboratories Ltd. in Pithampur, India (FEI 3006456888) at the end of a drug inspection that ended July 27, 2018. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 10, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 27, 2018
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Sep 10, 2018
- 45 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Cleaning procedures not validated
1. Cleaning procedures are not validated. Specifically, The Unichem Laboratories Ltd. procedure PPQA029/04 is not validated to assure API manufacturing equipment are cleaned to a level that does not impact product quality when employed for the multiple batch campaign process. The cleaning validation protocol did not completely describe the equipment to be cleaned, procedures, materials, acceptable cleaning levels, parameters to be monitored and controlled, and analytical methods. In addition, stability of the worst case condition defined by the completion of a full campaign of [illegible] batches was not defined, even though finished API has been distributed into the market for years.
- 2
Inaccurate HPLC calculations; OOS not investigated
2. Test procedures are not scientifically sound and appropriate to ensure that raw materials, intermediates, APIs, and labels and packaging materials conform to established standards of quality and/or purity. Specifically, [illegible] The review of the test results for the finished product testing of [illegible], USP Batch No. [illegible] (Related Compounds) (USP limit NMT 0.1%) did not correctly calculate and report a peak matching the location (relative retention time) on the chromatogram for Related Compound [illegible]. The peak matching Related Compound location in the sample sets [illegible] calculates to be approximately 0.3%, which would be Out Of Specification (OOS). The required investigation and reconciliation by Quality Assurance was not performed for this occurrence of an OOS event. Further review of Unichem Laboratories Ltd. procedure PPQC141/00, confirmed the company has a policy permitting any response attributed to a blank in HPLC analysis to be [illegible] without confirming the identity of the compound eluted, investigation, and notification of QA when a possible OOS occurs.
- 3
Laboratory controls not followed
3. Laboratory controls were not followed and documented at the time of performance. Specifically, Review of Unichem Laboratories Ltd. procedures for Media Preparation and Microbial Limits testing do not provide for an assurance of GMP compliance in the following examples: a. Media are not placed in a secure, quarantine state pending growth promotion before being released for use in Microbial Limits testing of raw materials, finished goods or stability monitoring. b. Microbial Limits testing procedures do not require the documentation of the specific incubator used in the performance of testing of raw materials, finished goods or stability monitoring. c. Microbial Limits testing procedures do not require the documentation of the specific time test media are placed into or removed from the incubator used in the performance of testing of raw materials, finished goods or stability monitoring.
- 4
Stability sample container records missing
4. There was no record of stability samples stored in containers that simulate the market container. Specifically, Review of the Unichem Laboratories Ltd. stability program records for Batch No.'s [illegible] and [illegible] found that there was no traceability for the materials of construction of containers used for the units created after the sample of the batch was delivered to the lab. There also was no record of who and when aliquots were created in preparation for stability storage.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.