Company: Unichem Laboratories Limited, India · Linked by exact D-U-N-S match (650055882) in FDA registration data
FDA has 6 inspections on file for Unichem Laboratories Limited in Pithampur, India (FEI 3006456888), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant, Unichem Laboratories Limited, India (D-U-N-S 650055882), has registered 4 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2025
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Cleaning procedures not validated
1. Cleaning procedures are not validated. Specifically, The Unichem Laboratories Ltd. procedure PPQA029/04 is not validated to assure API manufacturing equipment are cleaned to a level that does not impact product quality when employed for the multiple batch campaign process. The cleaning validation protocol did not completely describe the equipment to be cleaned, procedures, materials, acceptable cleaning levels, parameters to be monitored and controlled, and analytical methods. In addition, stability of the worst case condition defined by the completion of a full campaign of [illegible] batches was not defined, even though finished API has been distributed into the market for years.
- Observation 2
Inaccurate HPLC calculations; OOS not investigated
2. Test procedures are not scientifically sound and appropriate to ensure that raw materials, intermediates, APIs, and labels and packaging materials conform to established standards of quality and/or purity. Specifically, [illegible] The review of the test results for the finished product testing of [illegible], USP Batch No. [illegible] (Related Compounds) (USP limit NMT 0.1%) did not correctly calculate and report a peak matching the location (relative retention time) on the chromatogram for Related Compound [illegible]. The peak matching Related Compound location in the sample sets [illegible] calculates to be approximately 0.3%, which would be Out Of Specification (OOS). The required investigation and reconciliation by Quality Assurance was not performed for this occurrence of an OOS event. Further review of Unichem Laboratories Ltd. procedure PPQC141/00, confirmed the company has a policy permitting any response attributed to a blank in HPLC analysis to be [illegible] without confirming the identity of the compound eluted, investigation, and notification of QA when a possible OOS occurs.
Show observations 3 to 4
- Observation 3
Laboratory controls not followed
3. Laboratory controls were not followed and documented at the time of performance. Specifically, Review of Unichem Laboratories Ltd. procedures for Media Preparation and Microbial Limits testing do not provide for an assurance of GMP compliance in the following examples: a. Media are not placed in a secure, quarantine state pending growth promotion before being released for use in Microbial Limits testing of raw materials, finished goods or stability monitoring. b. Microbial Limits testing procedures do not require the documentation of the specific incubator used in the performance of testing of raw materials, finished goods or stability monitoring. c. Microbial Limits testing procedures do not require the documentation of the specific time test media are placed into or removed from the incubator used in the performance of testing of raw materials, finished goods or stability monitoring.
- Observation 4
Stability sample container records missing
4. There was no record of stability samples stored in containers that simulate the market container. Specifically, Review of the Unichem Laboratories Ltd. stability program records for Batch No.'s [illegible] and [illegible] found that there was no traceability for the materials of construction of containers used for the units created after the sample of the batch was delivered to the lab. There also was no record of who and when aliquots were created in preparation for stability storage.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Unichem Laboratories Limited, IndiaD-U-N-S 650055882
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Unichem Laboratories Limited, India (D-U-N-S 650055882) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Unichem Laboratories LimitedHupari, India · FEI 30135856792 inspections2latestFeb 2, 2026VAINone on file
- Unichem Laboratories LimitedDistrict Raigad, India · FEI 30043731807 inspections7latestJun 20, 2025VAINone on file
- Unichem Laboratories LimitedPilerne Bardez, India · FEI 30054975076 inspections6latestJul 15, 2024VAINone on file
- Unichem Laboratories LimitedGhaziabad, India · FEI 30040820767 inspections7latestFeb 13, 2024NAINone on file
Other FEIs recorded as Unichem Laboratories Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Unichem Laboratories LimitedFEI 3002808417Mumbai, India
Last inspected 2018-06-29VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3006456888 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3006456888. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.