Skip to content

FH Investments Inc. dba Asteria Health Form 483, July 2018

FDA issued this Form 483 to FH Investments Inc. dba Asteria Health in Birmingham, Alabama (FEI 3010348724) at the end of a drug inspection that ended July 10, 2018. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 10, 2018
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jan 17, 2024
2,017 days after the inspection
Facility
FEI 3010348724
Birmingham, Alabama

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Sterilization validation inadequate for implants

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, during (b) (4) sterilization validation, a. The bioburden and sterility method validation and suitability testing used for dose verification testing were not performed using testosterone and estradiol pellets made by your firm. b. The sterility and bioburden testing methods do not evaluate the entirety of each implantable pellet, only the external surfaces.

  2. 2

    Sterility testing only external surfaces

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, sterility testing of hormone pellets during (b) (4) only provides information for the exterior surfaces of the implantable pellets. There is no evaluation of the entire pellet.

  3. 3

    Cleaning validation and cross-contamination risk

    Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality, or purity of the drug product. Specifically, the equipment cleaning process has not been validated to ensure there is no cross-contamination between the hormone active pharmaceutical ingredients (APIs), testosterone and estradiol. The (b) (4) Pellet Press, (b) (4), is used for both API products and poses the highest risk for cross-contamination due to non-dedicated product contact parts. Other equipment used with both APIs include (b) (4) hoods, analytical balances, and calipers.

  4. 4

    Failure to properly investigate OOS assay

    There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has already been distributed. Specifically, the assessment of the investigation into the assay failure of an Estradiol 6 mg Pellet, Lot04252017@3, at the (b) (4) time-point lacks evidence to support invalidation of the out-of-specification (OOS) result.

  5. 5

    Complaint procedures lacking adverse event review

    Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010348724, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.