Skip to content

Daiichi Sankyo Co., Ltd. Odawara Plant

477, Takata, Odawara, Japan

FEI 3003279188

FDA has 3 inspections on file for Daiichi Sankyo Co., Ltd. Odawara Plant in Odawara, Japan (FEI 3003279188), from 2014 to 2019. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2014–2019
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
1 of 3
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Aug 19, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Primary reference standard characterization documentation incomplete

      Appropriate documentation of testing performed to fully establish the identity and purity of the in-house primary reference standard was not retained. Specifically, Your firm does not have complete documentation to verify the GMP status of the Sankyo Investigational Medicinal Product GMP laboratory equipment used to conduct the full characterization of the primary reference standard for ^(b) (4) lot ^(b) (4) ^(b) (4) in-house reference standard is used to conduct finished product release testing of ^(b) (4) drug substance.

    2. Observation 2

      Secondary standard not compared to primary standard

      Suitability of each batch of in-house secondary reference standard is not determined by comparison against a primary reference standard. Specifically, Since 2004, ^(b) (4) in-house reference standard lots have not been fully characterized or compared against a fully characterized primary reference standard. ^(b) (4) in-house reference standard is used to conduct finished product release testing of ^(b) (4) drug substance.

    Show observations 3 to 4
    1. Observation 3

      Stability testing not in marketed container closure

      The written stability program does not assure testing of the drug substance intermediate in the same container closure system as that in which it is marketed. Specifically, Stability testing of the drug substance intermediate, ^(b) (4) is not conducted in the same container closure system as that in which it is marketed.

    2. Observation 4

      Deviation investigations incomplete and limited in scope

      Written records of investigations into unexplained discrepancies are not always fully investigated. Specifically, Deviation investigations do not always extend to other processes that may have been associated with the specific failure or discrepancy and contain a conclusion and follow-up. Examples: 1) Deviation Number TPACD2017-001 - A glass ^(b) (4) fragment was collected in a strainer of a liquid delivery pipe in the ^(b) (4) production process. The investigation did not include analytical methods to identify or verify the identity of the material as glass and the investigation did not evaluate possible sources of contamination other than the production equipment. The investigation was closed without identifying a root cause and it was determined there was no impact to product quality. 2) Deviation Number COMD2018-007 - The ^(b) (4) (W26) in the F-10 Freezer, was not appropriately recorded. The investigation did not identify that a previous deviation, COMD2017-002, had documented a similar event that occurred within the last year and that corrective actions had been deemed effective in preventing further occurrences.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 19, 2026. It asked for a Form 483.

  • Inspection ending Jan 25, 2019VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 19, 2026FDA-FOIA-2026-7999Form 483· 1 of 3 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003279188 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003279188. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.