Skip to content

Daiichi Sankyo Chemical Pharma Co., Ltd. Form 483, January 2019

FDA issued this Form 483 to Daiichi Sankyo Chemical Pharma Co., Ltd. in Odawara, Japan (FEI 3003279188) at the end of a drug inspection that ended January 25, 2019. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 19, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jan 25, 2019
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 19, 2026
2,855 days after the inspection
Facility
FEI 3003279188
Odawara, Japan

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Primary reference standard characterization documentation incomplete

    Appropriate documentation of testing performed to fully establish the identity and purity of the in-house primary reference standard was not retained. Specifically, Your firm does not have complete documentation to verify the GMP status of the Sankyo Investigational Medicinal Product GMP laboratory equipment used to conduct the full characterization of the primary reference standard for ^(b) (4) lot ^(b) (4) ^(b) (4) in-house reference standard is used to conduct finished product release testing of ^(b) (4) drug substance.

  2. 2

    Secondary standard not compared to primary standard

    Suitability of each batch of in-house secondary reference standard is not determined by comparison against a primary reference standard. Specifically, Since 2004, ^(b) (4) in-house reference standard lots have not been fully characterized or compared against a fully characterized primary reference standard. ^(b) (4) in-house reference standard is used to conduct finished product release testing of ^(b) (4) drug substance.

  3. 3

    Stability testing not in marketed container closure

    The written stability program does not assure testing of the drug substance intermediate in the same container closure system as that in which it is marketed. Specifically, Stability testing of the drug substance intermediate, ^(b) (4) is not conducted in the same container closure system as that in which it is marketed.

  4. 4

    Deviation investigations incomplete and limited in scope

    Written records of investigations into unexplained discrepancies are not always fully investigated. Specifically, Deviation investigations do not always extend to other processes that may have been associated with the specific failure or discrepancy and contain a conclusion and follow-up. Examples: 1) Deviation Number TPACD2017-001 - A glass ^(b) (4) fragment was collected in a strainer of a liquid delivery pipe in the ^(b) (4) production process. The investigation did not include analytical methods to identify or verify the identity of the material as glass and the investigation did not evaluate possible sources of contamination other than the production equipment. The investigation was closed without identifying a root cause and it was determined there was no impact to product quality. 2) Deviation Number COMD2018-007 - The ^(b) (4) (W26) in the F-10 Freezer, was not appropriately recorded. The investigation did not identify that a previous deviation, COMD2017-002, had documented a similar event that occurred within the last year and that corrective actions had been deemed effective in preventing further occurrences.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.