Village Fertility Pharmacy, Inc.
335 Bear Hill Rd, Waltham, Massachusetts, United States
FEI 3008335877
FDA has one inspection on file for Village Fertility Pharmacy, Inc. in Waltham, Massachusetts (FEI 3008335877). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Jul 10, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2013
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Visible particulates in sterile Progesterone injectable lots
Visible particulates were seen in the following drug product lots which had been stored at the firm: • On 02/21/2013, we observed eighty-four (84) vials out of a bin containing (b) vials of Progesterone in Ethyl Oleate (with preservative) 50mg/mL from Lot EO31 (shipped to customers between 02/6/2013 - 02/16/2013 according to distribution data), a sterile injectable drug, to contain what appeared to be dark colored foreign matter. • On 02/22/2013, we observed 7 vials out of a bin containing (b) vials of Progesterone in Sesame Oil (with preservative) 50mg/mL from lot SO36 (shipped to customers between 02/13/2013 and 02/20/2013 according to distribution data), a sterile injectable drug, to contain what appeared to be whitish fibers or translucent filaments.
- Observation 2
Failure to evaluate product integrity incident reports
The firm failed to adequately evaluate product integrity incident reports, received from patients and healthcare practitioners, for injectable Progesterone produced in various solutions (e.g. sesame oil and ethyl oleate). Neither root-cause analysis nor corrective/preventive actions were identified or documented by the firm to avoid future occurrences of the incidents. For example: A. Two different incident reports were received for Progesterone in Ethyl Oleate which were not evaluated: • Product integrity incident report with date 07/01/2012 states a registered nurse reported black particles in Progesterone in Ethyl Oleate (Lot EO09). • Product integrity incident report dated 02/18/2013, states patient had a vial from the last order of Progesterone in Ethyl Oleate with particles floating in it. The patients' prescription for this product had been filled last on 01/07/2013. The lot number dispensed was not recorded. During a field examination on 02/21/2013, visible particulate (i.e. dark, black particles) was observed in approximately 84 of (b) vials examined of Progesterone in Ethyl Oleate Injectable 50mg/mL (Lot EO31, beyond use date 04/15/2013). This lot of Progesterone was made at the firm on 01/15/2013. B. A product integrity incident report with date 07/10/2012 states a patient used Progesterone in Sesame Oil and had a bad reaction. The medical doctor told the patient the medication was contaminated and to throw it away. During a field examination on 02/22/2013, visible particulate (i.e. whitish fibers) was observed in approximately 7 of (b) vials examined of Progesterone in Sesame Oil Injectable 50mg/mL (Lot SO36, beyond use date 04/09/2013). This lot of progesterone was made at the firm on 01/09/2013.
Show observations 3 to 4
- Observation 3
No documentation sterilization processes are effective
Although the formula worksheets state that the API and raw materials are non-sterile and the vials are sterile, the pharmacy technician responsible for mixing and filling all compounded products explained that the vials and stoppers are received non-sterile. The technician stated as of late 2012 she began to place some of the vials and stoppers into the (b) (4) prior to being used in filling. Of note, there is no documentation on the formula worksheet to indicate whether or not the stoppers and vials used in the filling of each lot had been previously processed through the (b) (4). The firm provided no documentation or evidence to support that the (b) (4) cycle that is used to sterilize the glass vials and stoppers is effective. In addition, the firm provided no documentation or evidence to support that the (b) (4) which used to sterilize progesterone and hydroxyprogesterone formulations using non-sterile API and raw materials is effective.
- Observation 4
Superpotent Leuprolide lot dispensed without investigation
On 11/23/2012, the firm made Leuprolide 40mcg/0.1ml, lot K2312-20, 5ml filled vials. The firm made a total of (b) vials. One vial was sent for potency testing on 11/30/2012, and the result was 78.72mcg/0.1ml (196.8% of the expected dose) which was reported on 12/10/2012. The firm dispensed eight of these vials to patients between 11/28/12 and 11/30/12. On 12/10/2012, the firm sent a second vial for testing, the potency result was 39.138mcg/0.1ml (97.8% of the expected dose). No investigation was performed by the firm.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008335877 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008335877. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.