Skip to content

Janssen Vaccines Corp.

23 Harmony-ro 303beon-gil,Yeonsu-gu, Incheon, Korea (the Republic of)

FEI 3012637764DUNS 688272061

Company: Janssen Research & Development, L.L.C. · Linked by exact D-U-N-S match (119237597) in FDA registration data

FDA has one inspection on file for Janssen Vaccines Corp. in Incheon, Korea (the Republic of) (FEI 3012637764). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Janssen Research & Development, L.L.C. (D-U-N-S 119237597), has registered 19 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2024
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Sep 24, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to submit BPDRs for complaints

      Responsibilities and procedures for quality units are not in writing and/or followed to ensure the FARS (BPDR) are submitted for the distributed products that are implicated with product quality issues. Specifically, You failed to follow your procedure, TV-WI-21853 Version 29.0 Product Quality Complaint Investigation (Effective date 5/25/2024) Section 7.11.1.2 that sets the requirement for FAR (BPDR) as, "***Two or more complaints with the same confirmed defect with same root cause for the same finished good lot or a root cause related to a common component lot in more than one finished good lot, with or without signal***". Your procedure, TV-SOP-31402 Version 6.0 Advisory Notices, US FDA Form 3911 (Drug Notification and Health Authority (HA) Communication - Reportable Events Procedure (Effective date 7/17/2024) sets the timeline for reporting BPDR as, "***as soon as possible, but no more than (b) (4) from the date the information is acquired***. Between 11/13/2023 and 11/8/2024, you recorded at least 25 market complaints for (b) (4) stopper (b) (4) for you (b) (4) Vial (b) (4) mg (b) (4) ml. Two and more complaints were received for the same lot. E.g., Two (2) complaints of (b) (4) were received for each of the Lot No's. (b) (4) (Mfg. date 6/20/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 7/5/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 8/8/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 8/10/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 12/12/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 2/16/2024, Expiry date (b) (4)). Three (3) complaints of (b) (4) were received for each of the Lot No's (b) (4) (Mfg. date 7/21/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 11/11/2023, Expiry date (b) (4)). In addition, a complaint for four (4) (b) (4) vials was received for Lot No. (b) (4) (Mfg. date 2/2/2024, Expiry date (b) (4)). Your Senior Director Business Director, Compliance (ET) stated that the investigation concluded the (b) (4) was not related to manufacturing process and hence the defect was not confirmed and no CAPA was implemented. Your Site Quality Head (SO) stated that the quality issue is related to end user and not with the drug product manufacturing.

    2. Observation 2

      Aseptic contamination prevention procedures not followed

      Procedure designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. A. On 11/13/2024, your vial filling operation recorded multiple interventions during the filling of (b) (4) Injection (b) (4) mg (b) (4) mL vial Batch No. (b) (4). During the filling, the vials got stuck simultaneously in IPC (b) (4) stoppering stations, and the vial (b) (4) (b) (4). The interventions took > (b) (4) that necessitated running IPC before the line was restarted. During the intervention, multiple adjustments were made, e.g., loosening and wiggling the (b) (4) (b) (4) bolts for IPC (b) (4), loosening and wiggling (b) (4), transferring a pair of extralong hemostat tweezers from one of the (b) (4) doors # 5. Transferring of a hemostat from (b) (4) door # 5, and use of a hemostat for removing the jammed vials are not part of an established/regular intervention, ID # (b) (4) Removal of Jammed and Broken Vial from (b) (4). According to your procedure, TV-WI-32841 Intervention in Aseptic Process (Effective date 9/12/2024), intervention ID # (b) (4) is done using (b) (4) gloves (b) (4) (b) (4) using tweezers stored in the (b) (4). The intervention ID # (b) (4) is simulated in your media fill for (b) (4). You used gloves (b) (4) and a hemostat. In addition, the intervention that required the use of gloves (b) (4) and a hemostat, took almost (b) (4) for much longer duration than you simulated in your media fill for (b) (4). Your QC Site Head (SO) initially insisted that this intervention was considered a regular intervention, ID # (b) (4) where a hemostat was used just like the one the firm uses for intervention, ID # (b) (4) Removal of Jammed (b) (4) Stoppers in (b) (4). A review of your smoke study for intervention ID # (b) (4) confirmed that the hemostat for (b) (4) used a (b) (4) like device at the tip of the hemostat to help with removing the (b) (4) stoppers. You finally decided to open a non-conformance. B. On 11/13/2024, at around (b) (4) during the filling of (b) (4) Injection (b) (4) mg Batch No. (b) (4), water condensation was seen on the inside of the goggle of one of production operator (BS) in the aseptic area. Your procedure, SOP No. TV-WI-15914 Version 18.0 Behavior in Aseptic Room and RABS (Effective date 8/8/2023), Section 7.1.14 states, "***When goggles get damp, operators should temporarily stop movement to minimize such damp or, if necessary, operators should change goggles***". C. On 11/13/2024, at around (b) (4) during the filling of (b) (4) Injection (b) (4) mg Batch No. (b) (4), your operators in the aseptic area were seen fully inserting the tweezers (b) (4) and hemostat by its tips inside the jammed vials and forcefully wiggling it to remove the jammed vials. Your operator was also seen placing the tweezer into the holders by rubbing against the body of the tweezer holder. Your procedure, SOP No. TV-WI-15914 Version 18.0 Behavior in Aseptic Room and RABS (Effective date 8/8/2023), Section 7.1.14 states, "***Be cautious not to let the tweezer tip touch the tweezer holder nor the tweezer body to rub against the holder when putting the tweezer into the tweezer holder***".

    Show observations 3 to 5
    1. Observation 3

      Deficient aseptic equipment and airflow monitoring

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, A. Aseptic filling processing of finished drug product i.e. from (b) (4) vials to aseptic filling and to glass vial sealing processing steps, are performed within a Grade A (ISO 5) environment. The following observation was made regarding your non-viable particle (NVP) monitoring: You manufacture (b) (4) Injection (b) (4) mg on you Vial Filler ID # B1-2018 that consists of (b) (4). You monitor airborne particles in the RABS with (b) (4) non-viable particle (NVP) counters ID's; (b) (4). (b) (4) (b) (4) of the NVP counters, (b) (4) are meant to monitor the (b) (4) (b) (4) and the NVP counter in the center of a (b) (4) of (b) (4) monitors the NVP on the (b) (4) vials. These (b) (4) NVP counters do not provide adequate coverage to assure that Grade A is maintained around and over the (b) (4) and (b) (4) vials. B. Your procedure, TV-SOP-40940 Version 18.0 Validation of Unidirectional Airflow (Laminar) Device (Effective date 11/6/2024) Section 5.3.7.5.1 specifies the acceptance criteria for smoke study as, "***Airflow should be linear and uniform without turbulence, eddies, or reflux in both At rest (static conditions) and In operation (dynamic condition) status. The following table lists several instances where the unidirectional airflow patterns could not be determined and/or observed. Note: the summary provided in the table is not intended to be an all-inclusive and/or exhaustive list of concerns, for example; Approximate time stamp (b) (4) RABS Setup: Transfer and Installation of (b) (4) Set, Chute, and (b) (4) Not enough smoke over left hand to observe unidirectional airflow (UDA) Not enough smoke over left hand to observe UDA Attaching the (b) (4) to filling line, not enough smoke to verify UDA Attaching the (b) (4) to filling line, right hand is blocked by left hand Tightening the (b) (4) assembly, not enough smoke to verify UDA (b) (4) (b) (4) Calibration Adjusting the IPC (b) (4) not adequate smoke to verify UDA Adjusting the (b) (4) with both hands: not enough smoke to UDA (b) (4) (b) (4) Sample Bag Replacement and (b) (4) Removing the sample bag, not enough smoke to verify UDA Replacing the sample bag, not enough smoke to verify UDA Removing the sample bag, not enough smoke to verify UDA

    2. Observation 4

      Deficient cleaning disinfection rough welded pipe

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, Your (b) (4) stoper transfer pipe was seen to have a small hook (~1.5 cm) like structure welded on the top of the pipe. The welding was rough and consisted of a crack at the welding site. On the inside of the pipe right beneath the welded hook, the surface was not smooth, appeared to be (b) (4) in color, and shedding the surface particle. You have recorded a complaint # 90000338418 for Uncharacteristic Color. This complaint was received for (b) (4) Vial (b) (4) mg (b) (4) mL Batch No. (b) (4) Mfg. date 2/7/2024, Expiry date (b) (4) for the drug product being (b) (4) color. No root cause was determined.

    3. Observation 5

      Inadequately qualified integrity test machines

      Equipment used in the manufacture, processing, packing, or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, Your firm's (b) (4) integrity test (b) (4) machines are not adequately qualified such that the (b) (4) (b) (4), and operating ranges (b) (4) associated with your drug products manufacturing are not adequately qualified. You carried out Operation Qualification in two parts; Parts 1 and 2. The OQ Part 1 is general functional testing of critical parameters, e.g., data entry, error messages, test on accuracy of pass/fail analysis, and running tests for test functions such as (b) (4). The Part 2 test is designed to verify the functionality of the instrument. You did not carry out OQ Part 1 test for your (b) (4) machines on site and used the vendor provided data (from a different (b) (4) machine) to supplement the OQ Part 1. The OQ Part 2 is merely a single point verification of the (b) (4) machines. E.g., the (b) (4) ID # B1-2755 is verified for (b) (4) (b) (4) at (b) (4) at (b) (4). You ensure (b) (4) integrity during (b) (4) of the drug product via measuring the specified (b) (4) at a specific (b) (4). You use (b) (4) product (b) (4) (b) (4). None of your (b) (4) machines (ID's (b) (4)) are qualified for any of the (b) (4). You used (b) (4) ID # B1-2370 to manufacture (b) (4) Injection (b) (4) mg Batch No's (b) (4) and (b) (4). Both baches recorded failed (b) (4) results for the (b) (4) (b) (4) closest to the filling line); Batch No. (b) (4) recorded (b) (4) failed (b) (4) test, Batch No. (b) (4) recorded (b) (4) failed (b) (4) test result. Your procedure allows (b) (4) failed (b) (4) results before a nonconference/deviation will be initiated.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Sep 24, 2025. Each one asked for a Form 483.

  • Inspection ending Nov 19, 2024OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jan 29, 2025FDA-FOIA-2025-820Form 483Closed
    2. Jan 16, 2025FDA-FOIA-2025-482Form 483Closed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Sep 24, 2025FDA-FOIA-2025-11232Form 483 + EIRWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Janssen Research & Development, L.L.C.D-U-N-S 119237597

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Janssen Research & Development, L.L.C. (D-U-N-S 119237597) as the registrant for this site and 19 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3012637764 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3012637764. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.