Janssen Vaccines Corporation Form 483, November 2024
FDA issued this Form 483 to Janssen Vaccines Corporation in Incheon, Korea (the Republic of) (FEI 3012637764) at the end of a drug inspection that ended November 19, 2024. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on July 18, 2025.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 6, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 19, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Mar 6, 2025
- 107 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Failure to submit BPDRs for complaints
Responsibilities and procedures for quality units are not in writing and/or followed to ensure the FARS (BPDR) are submitted for the distributed products that are implicated with product quality issues. Specifically, You failed to follow your procedure, TV-WI-21853 Version 29.0 Product Quality Complaint Investigation (Effective date 5/25/2024) Section 7.11.1.2 that sets the requirement for FAR (BPDR) as, "***Two or more complaints with the same confirmed defect with same root cause for the same finished good lot or a root cause related to a common component lot in more than one finished good lot, with or without signal***". Your procedure, TV-SOP-31402 Version 6.0 Advisory Notices, US FDA Form 3911 (Drug Notification and Health Authority (HA) Communication - Reportable Events Procedure (Effective date 7/17/2024) sets the timeline for reporting BPDR as, "***as soon as possible, but no more than (b) (4) from the date the information is acquired***. Between 11/13/2023 and 11/8/2024, you recorded at least 25 market complaints for (b) (4) stopper (b) (4) for you (b) (4) Vial (b) (4) mg (b) (4) ml. Two and more complaints were received for the same lot. E.g., Two (2) complaints of (b) (4) were received for each of the Lot No's. (b) (4) (Mfg. date 6/20/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 7/5/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 8/8/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 8/10/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 12/12/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 2/16/2024, Expiry date (b) (4)). Three (3) complaints of (b) (4) were received for each of the Lot No's (b) (4) (Mfg. date 7/21/2023, Expiry date (b) (4)), (b) (4) (Mfg. date 11/11/2023, Expiry date (b) (4)). In addition, a complaint for four (4) (b) (4) vials was received for Lot No. (b) (4) (Mfg. date 2/2/2024, Expiry date (b) (4)). Your Senior Director Business Director, Compliance (ET) stated that the investigation concluded the (b) (4) was not related to manufacturing process and hence the defect was not confirmed and no CAPA was implemented. Your Site Quality Head (SO) stated that the quality issue is related to end user and not with the drug product manufacturing.
- 2
Aseptic contamination prevention procedures not followed
Procedure designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. A. On 11/13/2024, your vial filling operation recorded multiple interventions during the filling of (b) (4) Injection (b) (4) mg (b) (4) mL vial Batch No. (b) (4). During the filling, the vials got stuck simultaneously in IPC (b) (4) stoppering stations, and the vial (b) (4) (b) (4). The interventions took > (b) (4) that necessitated running IPC before the line was restarted. During the intervention, multiple adjustments were made, e.g., loosening and wiggling the (b) (4) (b) (4) bolts for IPC (b) (4), loosening and wiggling (b) (4), transferring a pair of extralong hemostat tweezers from one of the (b) (4) doors # 5. Transferring of a hemostat from (b) (4) door # 5, and use of a hemostat for removing the jammed vials are not part of an established/regular intervention, ID # (b) (4) Removal of Jammed and Broken Vial from (b) (4). According to your procedure, TV-WI-32841 Intervention in Aseptic Process (Effective date 9/12/2024), intervention ID # (b) (4) is done using (b) (4) gloves (b) (4) (b) (4) using tweezers stored in the (b) (4). The intervention ID # (b) (4) is simulated in your media fill for (b) (4). You used gloves (b) (4) and a hemostat. In addition, the intervention that required the use of gloves (b) (4) and a hemostat, took almost (b) (4) for much longer duration than you simulated in your media fill for (b) (4). Your QC Site Head (SO) initially insisted that this intervention was considered a regular intervention, ID # (b) (4) where a hemostat was used just like the one the firm uses for intervention, ID # (b) (4) Removal of Jammed (b) (4) Stoppers in (b) (4). A review of your smoke study for intervention ID # (b) (4) confirmed that the hemostat for (b) (4) used a (b) (4) like device at the tip of the hemostat to help with removing the (b) (4) stoppers. You finally decided to open a non-conformance. B. On 11/13/2024, at around (b) (4) during the filling of (b) (4) Injection (b) (4) mg Batch No. (b) (4), water condensation was seen on the inside of the goggle of one of production operator (BS) in the aseptic area. Your procedure, SOP No. TV-WI-15914 Version 18.0 Behavior in Aseptic Room and RABS (Effective date 8/8/2023), Section 7.1.14 states, "***When goggles get damp, operators should temporarily stop movement to minimize such damp or, if necessary, operators should change goggles***". C. On 11/13/2024, at around (b) (4) during the filling of (b) (4) Injection (b) (4) mg Batch No. (b) (4), your operators in the aseptic area were seen fully inserting the tweezers (b) (4) and hemostat by its tips inside the jammed vials and forcefully wiggling it to remove the jammed vials. Your operator was also seen placing the tweezer into the holders by rubbing against the body of the tweezer holder. Your procedure, SOP No. TV-WI-15914 Version 18.0 Behavior in Aseptic Room and RABS (Effective date 8/8/2023), Section 7.1.14 states, "***Be cautious not to let the tweezer tip touch the tweezer holder nor the tweezer body to rub against the holder when putting the tweezer into the tweezer holder***".
- 3
Deficient aseptic equipment and airflow monitoring
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, A. Aseptic filling processing of finished drug product i.e. from (b) (4) vials to aseptic filling and to glass vial sealing processing steps, are performed within a Grade A (ISO 5) environment. The following observation was made regarding your non-viable particle (NVP) monitoring: You manufacture (b) (4) Injection (b) (4) mg on you Vial Filler ID # B1-2018 that consists of (b) (4). You monitor airborne particles in the RABS with (b) (4) non-viable particle (NVP) counters ID's; (b) (4). (b) (4) (b) (4) of the NVP counters, (b) (4) are meant to monitor the (b) (4) (b) (4) and the NVP counter in the center of a (b) (4) of (b) (4) monitors the NVP on the (b) (4) vials. These (b) (4) NVP counters do not provide adequate coverage to assure that Grade A is maintained around and over the (b) (4) and (b) (4) vials. B. Your procedure, TV-SOP-40940 Version 18.0 Validation of Unidirectional Airflow (Laminar) Device (Effective date 11/6/2024) Section 5.3.7.5.1 specifies the acceptance criteria for smoke study as, "***Airflow should be linear and uniform without turbulence, eddies, or reflux in both At rest (static conditions) and In operation (dynamic condition) status. The following table lists several instances where the unidirectional airflow patterns could not be determined and/or observed. Note: the summary provided in the table is not intended to be an all-inclusive and/or exhaustive list of concerns, for example; Approximate time stamp (b) (4) RABS Setup: Transfer and Installation of (b) (4) Set, Chute, and (b) (4) Not enough smoke over left hand to observe unidirectional airflow (UDA) Not enough smoke over left hand to observe UDA Attaching the (b) (4) to filling line, not enough smoke to verify UDA Attaching the (b) (4) to filling line, right hand is blocked by left hand Tightening the (b) (4) assembly, not enough smoke to verify UDA (b) (4) (b) (4) Calibration Adjusting the IPC (b) (4) not adequate smoke to verify UDA Adjusting the (b) (4) with both hands: not enough smoke to UDA (b) (4) (b) (4) Sample Bag Replacement and (b) (4) Removing the sample bag, not enough smoke to verify UDA Replacing the sample bag, not enough smoke to verify UDA Removing the sample bag, not enough smoke to verify UDA
- 4
Deficient cleaning disinfection rough welded pipe
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, Your (b) (4) stoper transfer pipe was seen to have a small hook (~1.5 cm) like structure welded on the top of the pipe. The welding was rough and consisted of a crack at the welding site. On the inside of the pipe right beneath the welded hook, the surface was not smooth, appeared to be (b) (4) in color, and shedding the surface particle. You have recorded a complaint # 90000338418 for Uncharacteristic Color. This complaint was received for (b) (4) Vial (b) (4) mg (b) (4) mL Batch No. (b) (4) Mfg. date 2/7/2024, Expiry date (b) (4) for the drug product being (b) (4) color. No root cause was determined.
- 5
Inadequately qualified integrity test machines
Equipment used in the manufacture, processing, packing, or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, Your firm's (b) (4) integrity test (b) (4) machines are not adequately qualified such that the (b) (4) (b) (4), and operating ranges (b) (4) associated with your drug products manufacturing are not adequately qualified. You carried out Operation Qualification in two parts; Parts 1 and 2. The OQ Part 1 is general functional testing of critical parameters, e.g., data entry, error messages, test on accuracy of pass/fail analysis, and running tests for test functions such as (b) (4). The Part 2 test is designed to verify the functionality of the instrument. You did not carry out OQ Part 1 test for your (b) (4) machines on site and used the vendor provided data (from a different (b) (4) machine) to supplement the OQ Part 1. The OQ Part 2 is merely a single point verification of the (b) (4) machines. E.g., the (b) (4) ID # B1-2755 is verified for (b) (4) (b) (4) at (b) (4) at (b) (4). You ensure (b) (4) integrity during (b) (4) of the drug product via measuring the specified (b) (4) at a specific (b) (4). You use (b) (4) product (b) (4) (b) (4). None of your (b) (4) machines (ID's (b) (4)) are qualified for any of the (b) (4). You used (b) (4) ID # B1-2370 to manufacture (b) (4) Injection (b) (4) mg Batch No's (b) (4) and (b) (4). Both baches recorded failed (b) (4) results for the (b) (4) (b) (4) closest to the filling line); Batch No. (b) (4) recorded (b) (4) failed (b) (4) test, Batch No. (b) (4) recorded (b) (4) failed (b) (4) test result. Your procedure allows (b) (4) failed (b) (4) results before a nonconference/deviation will be initiated.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJul 18, 2025Janssen Vaccines Corp., A Johnson & Johnson Company warning letter, July 18, 2025CDER · 241 days after this inspection ended
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.