Skip to content

Investigations and out-of-specification results in FDA Form 483 observations

How firms investigate what went wrong: out-of-specification and out-of-trend results, invalidated tests, unexplained discrepancies, deviations and root causes. FDAgent finds 231 such observations in 161 Form 483s issued to 150 facilities, for inspections that ended between March 2010 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
231
Each quoted below
Form 483s
161
Posted by FDA
Facilities
150
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 67 in 2026

Investigations and OOS results observations in Form 483s by inspection year
YearObservations
20101
20110
20123
20131
20141
20153
20169
201712
201812
201917
20202
202111
202220
202321
202416
202535
202667

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.192

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“out of specification” · “OOS” · “out of trend” · “OOT” · “invalidat*” · “root cause*” · “unexplained discrepanc*” · “thoroughly review*” · “thoroughly investigat*” · “not … investigated” · “inadequate investigation*” · “failure to investigate”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 231 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 4

    … Additionally, no formal investigation was initiated to assess the potential impact on product quality or to identify root causes of the sticking and breaking. B) Annual Product Quality Reviews (PQRs) have not been performed in accordance with section 5.2 of SOP-47 "Product Quality Review," for drug products, including, but not limited to, the following manufactured and packaged products in 2025: a. (b) (4) tablets b. (b) (4) tablets c. (b) (4) …

    Contains “root cause*”Read the Form 483 →

  2. Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 22

    … However, there is no documentation in your Out of Specification Logbook or Deviation Logbook.

    Contains “out of specification”Read the Form 483 →

  3. Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 1

    … to perform calculations for all unreported Related Substances and Assay injections, where at least one batch, (b)(4), revealed an unreported injection with an OOS result. Specifically, on 12/20/2024, your analyst injected a blank and single injection for sample (b)(4) with calculations during the current inspection resulting in OOS for assay, with calculated result as (b)(4)% versus specification of (b)(4)%. The official reported result …

    Contains “OOS”Read the Form 483 →

  4. Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 6

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Complaint CM (b)(4)/002/25 was received via email on January 16, 2025, from a customer regarding an out-of-specification (OOS) result for an unspecified impurity in the Related Substances by HPLC test during analysis of …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  5. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 1

    … A) Failing non-viable particulate testing data present in the history of (b) (4) Particle Counters is not investigated for product impact, documented as a part of the testing record, or otherwise evaluated. Instances of such findings are summarized as follows: No. Date Controlled Form Sampling Location Official Documentation Instrument Data Acceptance Criteria for ≥0.5 µm particles Discrepancy 1 3-Jan-2025 (b) (4) Action level excursion not …

    Contains “not … investigated”Read the Form 483 →

  6. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 2

    … Your cancelled deviations demonstrate a pattern of data entry errors and procedural failures that were not investigated for root cause or addressed through your quality management system. Examples of cancelled deviations include: QE-025817 was initiated on April 11, 2025, for Thymoglobulin batch (b) (4) after a team member observed a broken vial on the (b) (4) The deviation was subsequently cancelled based on a QA Expert Comment stating that (b) …

    Contains “not … investigated”Read the Form 483 →

  7. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 5

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) Complaint 493112 pertaining to "Foreign Matter After Reconstitution" found in Thymoglobulin lot (b) (4) described brown particulate or blemish on the inside of the vial that was removable when wiped with a cloth. The …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  8. Smithfield Biosciencs, Inc.Inspection ended Dec 23, 2025 · FEI 1527761 · Observation 1

    … Your firm processed product code batches and (b) (4) product code batches during process validation due to various significant deviations and OOS results, such as product Color, atypical Loss on Drying, Total Plate Count failures, and other issues. This caused your firm to make additional batches in order to achieve process validation criteria of three consecutive product batches meeting specification. Your firm has released approximately (b) (4) …

    Contains “OOS”Read the Form 483 →

  9. Smithfield Biosciencs, Inc.Inspection ended Dec 23, 2025 · FEI 1527761 · Observation 4

    ***REPEAT OBSERVATION FROM FDA 2019 INSPECTION*** Failure to conduct thorough investigations into unexplained discrepancies and the failure of a batch to meet any of its specifications. Specifically, A.) Your complaint investigation #137 for an additional doublet peak in the NMR spectra around (b) (4) ppm has not been thoroughly investigated. The identity of this peak has not been identified to date and retrospective analysis of previous NMR …

    Contains “unexplained discrepanc*”Read the Form 483 →

  10. Dr. Reddy’s Laboratories LimitedInspection ended Dec 12, 2025 · FEI 3009193040 · Observation 1

    OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, (b)(4)(b)(4) A. On 4/28/2025, you recorded non-conformances 310028189 and 310028200 for (b)(4)(b)(4)(b)(4) for Dissolution by HPLC. The OOS results were recorded (b)(4)(b)(4)(b)(4) for Batch No’s. (OOS No. …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  11. Dr. Reddy’s Laboratories LimitedInspection ended Dec 12, 2025 · FEI 3009193040 · Observation 5

    … You have recorded multiple OOS results for drug products for related substances where APIs (b)(4) were sampled with sterile scoops and spoons. Some such examples are listed in Table 1. Table 1. Sampling of APIs (select examples) Entry API Batch No. Sampling tool Drug Product Name Batch No. OOS No. Test (b)(4) (b)(4) (b)(4) 1 Sterile scoop 310028627 Related Substances Measuring (b)(4) (b)(4) , (b) (b)(4) (b)(4) scoop and (b)(4) 310028958 Related …

    Contains “OOS”Read the Form 483 →

  12. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 1

    … locations (b)(4), (b)(6) December 3rd, 2025 PM locations (b)(4) (b)(4) December 1st, 2025 EM location [illegible] For each of the above samples any growth is OOS. 2. On December 5th, 2025 the following plates exhibited failing results at (b)(4) of incubation - (b)(4), (b)(6). These plates were discarded and replaced with unused plates. Any growth for these sampling locations would be considered OOS. E. Your Quality Control laboratory practices …

    Contains “OOS”Read the Form 483 →

  13. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 7

    The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. A. You do not document quality system events such as deviation, OOSs and changes. 1. No deviations or OOS were generated for the EM/PM deficiencies nor for any discarded QC records identified during the inspection. 2. per Microbiology (b)(4) testing forms changes were made approximately (b)(4) (b)(6) samples. No Manager, subsequently …

    Contains “OOS”Read the Form 483 →

  14. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 1

    … a) The (b)(4) Tank and Tank Transfer Line samples endotoxin out of specification (OOS) results obtained on 11/03/2025 were not recorded and reported. They were later replaced with the within acceptance results from different samples by QC Microbiology Team Lead. The passing results were reported in the final certificate of analysis (COA). b) The media plates that showed alert level colony forming units (CFU) at the completion of incubation on …

    Contains “out of specification”Read the Form 483 →

  15. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 2

    Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, From 01/2023 to date, a total of 39 complaints from the U.S. market were received regarding (b)(4) Injection USP being ineffective. No root cause was assigned for drug ineffectiveness. (b)(4) batches In 2022, out of the total received ineffective complaints (each batch can receive multiple complaints). Additionally …

    Opens with FDA's citation wording for 21 CFR 211.192Read the Form 483 →

  16. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 3

    There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. The firm's OOS investigation OS-LC23-006 was inadequate. OS-LC23-006 was initiated following an OOS result for unknown substance in finished product (b)(4) Injection (b)(4) Batch (b)(4). The OOS for Batch (b)(4) found unknown …

    Contains “thoroughly review*”Read the Form 483 →

  17. HEC Pharm Co. Ltd.Inspection ended Nov 21, 2025 · FEI 3006259537 · Observation 1

    Analytical method used for determination of impurities in API is inadequately validated. Specifically, the impurity method used for determination or quantification of impurities in (b)(4) Active Pharmaceutical Ingredient (API) did not detect the presence of an unknown impurity (b)(4) was initiated for assay OOT for (b)(4) in the test sample solution. On 02/20/2025, OOT (b)(4) During the investigation, an unknown peak was detected in (b)(4) batch …

    Contains “OOT”Read the Form 483 →

  18. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 5

    … Your firm failed to perform adequate environmental monitoring (EM) excursion investigations to address the root cause of positive microbial contamination found during routine environmental monitoring and personnel monitoring during the manufacture of sterile (b) (4) drug products manufactured in (b) (4) Moreover, your firm trends the excursions as per the specific location and not considering other impacted locations within the classified areas …

    Contains “root cause*”Read the Form 483 →

  19. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 6

    … For example, repeated Out-of-Specification (OOS) results have been observed during the HPLC assay analyses of (b) (4) Crude and sterile materials. Although low sample injection volume was identified as the root cause, the recurrence of these events indicates insufficient analytical method controls to ensure assay reliability. Investigation # Date Product Name Batch # OOS Result Specification Range Conclusion E2OOS240003 (b) (4) OOS observed is …

    Contains “out of specification”Read the Form 483 →

  20. Lonza Guangzhou Pharmaceutical Ltd.Inspection ended Oct 31, 2025 · FEI 3006532186 · Observation 2

    OBSERVATION 2 There is a failure to thoroughly review any unexplained discrepancy and the failure to [illegible] of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, The quality unit failed to provide adequate complaint investigations. For example, a. The complaint investigation associated to the presence of black particles during the use of API, batch …

    Contains “thoroughly review*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about investigations and OOS results in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.