Swati Spentose Private Limited Form 483, May 2024
FDA issued this Form 483 to Swati Spentose Private Limited in Vapi, India (FEI 3009765202) at the end of a drug inspection that ended May 31, 2024. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 12, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 31, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 12, 2026
- 895 days after the inspection
The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
QC reviewers lack role-specific training qualification
Employees are not given role specific training to perform their function. Specifically, As per SOP # QCD/0117/000, "Procedure for Review of Analytical Documents and Reviewer Qualification", the QC laboratory reviewer who reviewed the testing data needs to be trained and qualified to perform the review of the analyzed test however your firm failed to ensure that all Quality Control (QC) laboratory reviewers are adequately trained to review laboratory data for product release. For example, A) Residual Solvents test by Gas Chromatography (GC) was performed on 02/14/2024 for (b)(4) USP, batch #(b)(4). The QC laboratory reviewer who reviewed the testing data was not properly trained and qualified to perform the review of the analyzed test. B) Residual Solvents test by Gas Chromatography (GC) was performed on 09/26/2023 for (b)(4), batch #(b)(4). The QC laboratory reviewer who reviewed the testing data was not properly trained and qualified to perform the review of the analyzed test.
- 2
QC procedures not followed, repeated human errors
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm failed to ensure that all Quality Control (QC) laboratory personnel perform product testing according to approved testing procedures. Over one hundred OOS/Incidents investigations have been concluded as human errors since Jan 2021 despite ongoing retraining and requalification of analysts. Human errors in the QC lab such as incorrect entry of the sample details into LIMS system, dilution error, preparation error, wrong weight error, weight transfer error etc. have occurred repeatedly since January 2021 (as shown in the table below) despite of corrective actions including awareness training, retraining and requalification of analysts. [Table - Year of evaluation / Number of Human errors: 2021 - Incorrect entry 26, Preparation error/Dilution error 39, Error due to overlook 36, Weighing error/weight transfer error 24, Incorrect data path 12; 2022 - Error due to overlook 36, Preparation error 41, Incorrect entry 24, Other error 28; 2023 - Error due to overlook 67, Preparation error 21, Transcription error 12, Other error [illegible]] 1. INC-01-23-0342 was opened on 09/15/2023 to investigate OOS results for Water Content by KF for (b)(4), Lot #(b)(4). It was determined that the transfer of (b)(4) weight (a human error) was not properly performed by the QC Analyst. A similar incident was opened about 6 months ago on 03/30/2023 under INC-01-23-0145 to investigate OOS results for Water Content by KF for (b)(4), Lot #(b)(4) [illegible] performed by the same QC Analyst. The corrective actions, including awareness training, (b)(4) implemented had proven to be ineffective.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.