Skip to content

GlaxoSmithKline Biologicals Kft. Form 483, January 2025

FDA issued this Form 483 to GlaxoSmithKline Biologicals Kft. in Godollo, Hungary (FEI 3008322822) at the end of a biologics inspection that ended January 31, 2025. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jan 31, 2025
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 20, 2026
627 days after the inspection
Facility
FEI 3008322822
Godollo, Hungary

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate deviation investigations for worst-case conditions

    Discrepancy and failure investigations related to manufacturing were not expanded to assess worst case conditions. Specifically, a) Deviation 201042740 initiated on 09JAN2024, pertaining to particulate contamination of (b)(4) was not adequately investigated. Your (b)(4) sent for analysis during the [illegible] identified an (b)(4) within a (b)(4) deviation investigation. However, you failed to perform an adequate risk analysis that included worst case conditions to support the utilization of (b)(4) during [illegible]. This batch manufacturing of (b)(4) batch (b)(4) was released and distributed for further manufacture of final drug products INFANRIX (lots (b)(4)) and BOOSTRIX (lot (b)(4)). b) Deviation 201079963 was initiated on 25JUL2024 pertaining to a (b)(4) (17 total (b)(4)) storage temperature excursion. This batch was identified as out of controlled temperature for (b)(4) hrs with the warmest temperature reaching (b)(4). You failed to evaluate product impact for all 17 (b)(4) and failed to adequately investigate and justify your viability testing sample was representative of worst-case conditions. This (b)(4) was released for further manufacture of (b)(4) batches (b)(4) and (b)(4).

  2. 2

    Inadequate component acceptance procedures

    Procedures for the acceptance and rejection of components and materials utilized within drug substance manufacturing are not adequate. Procedure LSOP 9000087267 (ver. 01 – approved 20MAR2024), titled "FILT.UF (b)(4)" was implemented as a corrective action in response to deviation 201042740 and prior to use within manufacturing. The procedure requires visual inspection of the (b)(4). The procedure allows for the acceptance and use of (b)(4) containing (b)(4) with (b)(4) within [illegible]," however, no risk assessment or study was conducted to assess the impact of utilizing (b)(4) in your (b)(4) process.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.