Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, A. Your cleanroom certification conducted on June 29, 2026, and June 30, 2026, shows that HEPA Filter [illegible] in Production Room [illegible] (ISO 7) did not pass airflow and (b)(4) as the report states the result as N/A and notes "HEPA Filter 8 in need of motor replacement." Your firm …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  2. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 2

    … Your firm's process media fill (MFP), qualifying your operators to perform aseptic operations, were not signed by your Quality Unit before your operators participated in production batches: Process Media Fill Elapsed Event Date Completed Date Signed by Quality Unit Associated Time [illegible] January 19, 2026 April 8, 2026 No Events 79 days [illegible] January 26, 2026 April 22, 2026 No Events 86 days [illegible] January 7, 2026 March 11, 2026 No …

    Contains “media fill*”Read the Form 483 →

  3. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 3

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, Smoke studies conducted on December 31, 2025, did not adequately reflect observed production operations. On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), were …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  4. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On August 5, 2026, video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed (b)(4), were reviewed. During this video review the following was observed: 1. Your production operators were observed placing the settle plates in the corners of the LAFHs before the start …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  5. OurPharma LLCInspection ended Aug 12, 2026 · FEI 3014064135 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, • (b)(4) Sterilization Performed in an ISO 8 Classified Room Batch records collected during the inspection confirm that (b)(4) sterilization was performed in Compounding Room (b)(4) which is classified as ISO 8. Specifically: Batch production records for two lots of Fentanyl …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  6. OurPharma LLCInspection ended Aug 12, 2026 · FEI 3014064135 · Observation 3

    … The two longest investigations — OOS-25-09-004 (205 days, sterility failure, lot 1013-25-08-0005) and OOS-25-09-020 (98 days, sterility failure, lot 1013-25-09-0002) — remained open well beyond the firm's stated (b)(4)-day threshold. Because the SOP does not define completion timelines, extension criteria, or approval requirements, there is no procedural mechanism to ensure investigations are completed in a timely manner or that justifications …

    Contains “sterili*”Read the Form 483 →

  7. Brookfield Medical Surgical Supplies IncInspection ended Jul 10, 2026 · FEI 3011430551 · Observation 3

    OBSERVATION 3 Procedures designed to prevent microbiological contamination are not followed. Specifically, The environmental monitoring program of your firm allows for a CFU limit for gloved fingertips in an ISO-5 area. For a COMP compliant 503B facility, the action level must be any detected organism. Furthermore, your firm failed to investigate and identify the microbial growth recovered from the ISO-5 environment at the facility. All the …

    Contains “ISO 5”Read the Form 483 →

  8. Dr. Reddy's Laboratories Ltd.Inspection ended Jun 25, 2026 · FEI 3014250111 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate aseptic practices. During filling of (b)(4) drug product batch (b)(4) on June 18, 2026, in the filling line, number (b)(4) inadequate aseptic practices were observed. Specifically, A. The (b)(4) and stopper bowl were assembled into the (b)(4) and were uncovered prior to initiation of the (b)(4) decontamination cycle. As a …

    Contains “purporting to be sterile”Read the Form 483 →

  9. Dr. Reddy's Laboratories Ltd.Inspection ended Jun 25, 2026 · FEI 3014250111 · Observation 2

    Aseptic processing environmental monitoring procedures are inadequate in the (b)(4) filling line. Specifically, A. On June 24, 2026, following filling of (b)(4) drug product batch number (b)(4), environmental monitoring failed to include viable surface monitoring of the (b)(4) and stopper bowl. The inadequate (b)(4) design does not allow for effective monitoring strategies for these indirect product-contact surfaces, which compromises sterility …

    Contains “aseptic*”Read the Form 483 →

  10. Dr. Reddy's Laboratories Ltd.Inspection ended Jun 25, 2026 · FEI 3014250111 · Observation 4

    Aseptic practices observed in air visualization studies drug product filling operations are inadequate in that first air was obstructed in different (b)(4) critical zones during aseptic processing interventions. Specifically, i. Airflow visualization (smoke) studies conducted on 17/12/2024 (December 17, 2024) for Intervention: Filling machine (b)(4) adjustment vial maximum load (b)(4) at (b)(4), show that a (b)(4) positioned above the (b)(4) …

    Contains “aseptic*”Read the Form 483 →

  11. Dr. Reddy's Laboratories Ltd.Inspection ended Jun 25, 2026 · FEI 3014250111 · Observation 7

    Your firm failed to ensure that operators working in aseptic manufacturing areas are adequately trained, as evidenced by deficient On-the-Job Training (OJT) records for personnel in the (b)(4) area. Specifically, Review of the On-the-Job Training Record (record number (b)(4)) for Employee ID: (b)(6) shows that individual skill training sessions for critical aseptic manufacturing operations were documented as lasting as few as 29 minutes …

    Contains “aseptic*”Read the Form 483 →

  12. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. A (b)(4) trial run was conducted on June 16 - 17, 2026 to simulate the aseptic injection, (b)(4) mg/vial filling and (b)(4) process for (b)(4) and (b)(4) injection (b)(4) mg/vial. The following deficiencies were observed: 1. The vial sampling tray used to conduct manual fill weight …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  13. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. According to the Quality Head, the following (b)(4) sensors, identified as part of the vial (b)(4) process, have not been calibrated or verified: System Component P&ID (Sensor Names) (b)(4) (b)(4) System (b)(4). There is no calibration record for such sensors involving …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  14. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 3

    … The Quality Head stated that this was due to future plans to install an additional camera inside the Grade A environment. The firm's CAPA report further states that some of the interventions, which are performed from filling to (b)(4) loading/unloading are not clearly visible from CCTV camera and there is no feasibility of view panel to verify aseptic intervention execution (behaviour and technique). However, activity is now monitored by real …

    Contains “Grade A”Read the Form 483 →

  15. Cytovance Biologics Inc.Inspection ended Jun 17, 2026 · FEI 3006341547 · Observation 2

    Equipment used in the manufacture of active pharmaceutical ingredients is not fully qualified. Specifically, A. Smoke studies performed during the performance qualification of the ISO 5 biological safety cabinets (BSC) and laminar flow hoods (LFH) in Building (b) (4) are inadequate to evaluate unidirectional airflow and contamination risk. To manufacture the drug substance (b) (4), your firm uses the following equipment for cell thaw ((b) (4); …

    Contains “smoke stud*”Read the Form 483 →

  16. XeCare LLCInspection ended Jun 17, 2026 · FEI 3017865039 · Observation 2

    OBSERVATION 2 Materials were exposed to lower than ISO 5 quality air. Specifically, On 5/16/2026, during production of Semaglutide 5mg/2mL Solution for Injection, lot CERKTLEQQQIJ, we observed, via video review, the following poor transfers of material into the ISO-5 hood resulting in the material being exposed to the ISO-7 environment. At approximately 7:17pm the filling technician passed two inner bags of sterile tweezers into the ISO-5 hood …

    Contains “ISO 5”Read the Form 483 →

  17. Fayetteville VA Medical CenterInspection ended Jun 15, 2026 · FEI 1073803 · Observation 2

    Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, Areas of reddish-brown and opaque discoloration/staining were observed on the ceiling [illegible] cover within the ISO-5 (b)(4) S/N: (b)(4). On 06/08/2026, we observed a technician conduct cleaning and disinfection of the ISO-5 (b)(4) S/N: (b)(4). We observed that the technician failed to clean the recessed area of a (b)(4) …

    Contains “sterili*”Read the Form 483 →

  18. Fayetteville VA Medical CenterInspection ended Jun 15, 2026 · FEI 1073803 · Observation 3

    Beta-lactam drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The firm has routinely produced both Beta-lactam and non-Beta-lactam products within the same ISO-5 (b)(4) (S/N: (b)(4)) and (b)(4) (S/N: (b)(4)). During this time the firm has failed to conduct decontamination of the (b)(4) to prevent potential …

    Contains “ISO 5”Read the Form 483 →

  19. Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, I. Your firm failed to enact adequate production process controls for manufacturing of commercial sterile drug product. For example: a. Your firm failed to provide documented evidence to demonstrate the use of (b)(4) goggles in the Grade A and B cleanroom spaces and its potential impact in …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  20. Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 2

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your firm's investigations into personnel monitoring (PM) action level excursions at failed to assess aseptic gowning practices such as the use of (b)(4) goggles as a potential root cause. Data for the facility shows action level recoveries of skin flora at the chest and/or forehead of 1 CFU/mL or more in your …

    Contains “aseptic*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.