Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 3

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, There is no sterility or endotoxin test data for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond …

    Contains “sterili*”Read the Form 483 →

  2. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 5

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a. There are no smoke studies conducted under dynamic conditions in the ISO 5 laminar flow hood where aseptic operations are performed to verify there is no obstruction or alteration of the HEPA-filtered air. b. There is no continuous monitoring of differential air pressure between the ISO 5 laminar flow …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  3. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 6

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no monitoring of viable particles, non-viable particles, work surfaces or personnel in the ISO 5 laminar flow hood where aseptic operations are performed.

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  4. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 7

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions. Specifically, Sporicidal disinfectants are not used to clean/disinfect the ISO 5 laminar flow hood.

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  5. Medi-Fare Drug and Home Health Center, Inc.Inspection ended Sep 12, 2014 · FEI 3009925820 · Observation 1

    1) Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) The firm currently utilizes (b)(4) to disinfect inside the ISO 5 Laminar Air Flow Work Benches (aseptic processing areas); nonetheless, these disinfecting agents are not sterile. b) Disinfecting and sporicidal agents, including dilution, being utilized for aseptic processing areas have …

    Contains “aseptic*”Read the Form 483 →

  6. DNA Pharmacy Services Inc dba Palm Beach CompoundingInspection ended Aug 13, 2014 · FEI 3004962739 · Observation 2

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, Testosterone Cypionate Injection 220 mg/mL Lot 03/02/2014:1106 produced on 03/02/2014 is currently distributed with a BUD of 12/27/2014 (9 months) even though there is no current sterility and endotoxin testing data to demonstrate that this lot is safe, effective, and stable for nine months.

    Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →

  7. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 1

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically: a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 7 clean room do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 laminar flow benches where products are aseptically processed. b). The wall …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  8. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 2

    Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. • Sterile drug products are aseptically manipulated by the cleanroom operators who were observed wearing non-sterile gowns, non-sterile glasses/goggles, non-sterile footwear, and non-sterile facial masks. The procedure operators use to put on sterile gloves used at the chemo ISO work area is performed in a way as to risk contamination, …

    Contains “aseptic*”Read the Form 483 →

  9. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm has never monitored viable air counts. b. Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. This was last performed on 10/18/13 …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  10. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 4

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a. Sterile wipes which are used to disinfect the ISO 5 hoods' sterile processing surfaces are composed of particle shedding material. b. The firm does not use sporicidal agents to disinfect the ISO 5 surfaces. c. In the disinfection of the chemotherapy ISO 5 hoods, non-sterile wipes are used …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  11. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 5

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. No media fills/process simulations have been performed under the most stressful or challenging conditions/worst case scenarios and according to a written protocol. In the absence of a media fill record and having not defined the frequency of interventions, type of interventions, the target amounts of …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  12. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 6

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, given the observed inadequate environmental controls, testing is deficient in that: a. Your firm has not conducted sterility testing for any batches (totaling [illegible] units) of outsourced sterile drugs since the registration date of 01/24/14. b. Endotoxin testing has not been performed for …

    Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →

  13. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 10

    Containers and closures are not reviewed for conformance with all appropriate written procedures. Specifically, Your firm does not receive or review certificates of analysis showing sterility for the sterile containers, such as IV bags, used for sterile drug products. Purchased sterile equipment, such as transfer tubing, are accepted into inventory and used for sterile drug processing without reviewing the manufacturer's certificate of analysis …

    Contains “sterili*”Read the Form 483 →

  14. Village Fertility Pharmacy, Inc.Inspection ended Mar 13, 2013 · FEI 3008335877 · Observation 3

    … The firm provided no documentation or evidence to support that the (b) (4) cycle that is used to sterilize the glass vials and stoppers is effective. In addition, the firm provided no documentation or evidence to support that the (b) (4) which used to sterilize progesterone and hydroxyprogesterone formulations using non-sterile API and raw materials is effective.

    Contains “sterili*”Read the Form 483 →

  15. ARL Biopharma, Inc. dba Analytical Research LaboratoriesInspection ended Nov 8, 2012 · FEI 3003644883 · Observation 1

    1. Your firm states on the Microbiology Report that is issued to a client after sterility and/or fungal testing that the Test Method employed was USP <71>. However, your firm is not fully following all parts of USP <71> when performing sterility and/or fungal testing of human drug products. For example, a. USP <71> requires a Method Suitability Test be performed for all new products tested. Your firm does not have documentation to show that …

    Contains “sterili*”Read the Form 483 →

  16. Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, the design of the personnel entryways, personnel and material traffic flows and gowning practices, particularly with regard to dedicated plant uniforms, captive plant shoes and shoe covers, is deficient. The current [illegible] promotes the propagation of microbial contamination. The following was observed …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  17. Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 2

    … There were 2 incidents within the past 2 months of city water leaking from sprinkler heads located in your aseptic areas; these sprinkler heads and piping had been replaced by your contractor during a recent shutdown. • Incident PRID: 95301 occurred 17 Aug 2012 near lyophilizer [illegible] (room 335, 335B) during the unloading of [illegible] drug product. The root cause of the leak was attributed to the tapering of the threading between the …

    Contains “aseptic*”Read the Form 483 →

  18. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 6

    [illegible] studies executed August 2007 during the operational qualification of the HVAC system for fill suite FF2-16, did not demonstrate the following: Critical aseptic connections [illegible] Routine functions of aseptic core operators, for example: a. manually placing stoppers or reorienting stoppers using forceps for filled vials b. withdrawing unfilled vials from the filling line for weight checks c. redirecting filled vials [illegible] …

    Contains “aseptic*”Read the Form 483 →

  19. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 7

    The aseptic filling of all drug products into vials at higher speeds on the [illegible] filling line has not been adequately qualified for its current use. [illegible] per [illegible] line is currently run [illegible] for the 20 ml vials. The data reported in validation studies documents that above [illegible] per minute, the stoppers clog in the stoppering machine and performance of the machine is affected.

    Contains “aseptic*”Read the Form 483 →

  20. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 8

    The procedure "Surface Monitoring [illegible]" QC-019-02, version 03/11/2008 does not require personnel exiting the aseptic fill suite to [illegible] on the [illegible] Additionally, personnel monitoring observed on September 16, 2008 exhibited [illegible]

    Contains “aseptic*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.