Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 1

    Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, Periodic Air and Surface Environmental Monitoring A. There was an action level (b)(4) active air sample in ISO 5 LFH (Hood) on 11/26/25. Sample ID #BHT112625NHDH1, result = 15 cfu, action limit for ISO 5 air samples is [illegible] cfu. Microorganisms were identified as Micrococcus species and coag-negative Staphylococcus species. There was …

    Contains “ISO 5”Read the Form 483 →

  2. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 2

    Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, sterile production technicians did not always use slow and deliberate movements in the ISO 5 LHFs and ISO 7 Buffer Rooms. Technicians moved quickly during cleaning, LHF setup, and filling and stoppering of multiple sterile injectable drugs on 09/15/26.

    Contains “unidirectional*”Read the Form 483 →

  3. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 3

    Use of non-sterile disinfecting agents and cleaning wipes in the ISO 5 area and classified areas. Specifically, sterile (b)(4) wipes, bottles of sterile (b)(4) solution, and bottles of sterile (b)(4) remained open in the ISO 7 Buffer Rooms indefinitely while technicians actively used these items to disinfect and clean items that entered the ISO 5 LHF and ISO 7 Buffer Rooms on 09/15/26.

    Contains “ISO 5”Read the Form 483 →

  4. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 5

    Smoke studies were inadequately performed under dynamic conditions. Specifically, smoke studies did not introduce smoke into the entire ISO 5 LFH to confirm unidirectional airflow throughout the aseptic processing area. Additional technicians in the ISO 7 Buffer Rooms during the smoke studies were stationary which was not representative of routine production. I reviewed the most recent smoke studies completed in April 2026 for Hood and Hood in …

    Contains “smoke stud*”Read the Form 483 →

  5. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 6

    Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, A. There was visible adhesive facing upward on the partially unsecured tape attempting to secure the damaged height adjustment control panel underneath the worksurface of ISO 5 Hood. The exposed adhesive was within six inches of the seated technician filling multiple lots of Semaglutide 2.5 mg/mL on 09/15/26. B. …

    Contains “ISO 5”Read the Form 483 →

  6. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 7

    Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, I watched a sterile production technician don sterile garb inside the ISO 8 Anteroom about two to four feet away from a laboratory support technician who was manually washing about 15 soiled glassware items in the approximately four-foot-wide sink. The production technician entered the Lane ISO 7 Prep Room. Flow of …

    Contains “gown*”Read the Form 483 →

  7. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 8

    Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, media fills are not always conducted under the most challenging and stressful conditions. Technicians work (b)(4) shifts, but there is no requirement for media fills to occur at the end of a technician's shift when they are presumably most fatigued. The end of the shift ensures the …

    Contains “media fill*”Read the Form 483 →

  8. Strive Pharmacy LLCInspection ended Sep 28, 2026 · FEI 3021042485 · Observation 9

    Inadequate routine environmental monitoring in the classified areas. Specifically, stools positioned at all (b)(4) ISO 5 LFH are not included in the EM surface sample program. I observed technicians in the Lane ISO 7 buffer room and the Lane ISO 7 buffer room directly contact a stool with their gloved hands during filling operations for sterile injectable drugs. Technicians sit on the stools while filling. Technicians sit on a bench in the ISO 8 …

    Contains “ISO 5”Read the Form 483 →

  9. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 1

    … On August 31, 2026, your firm was directly observed using the above-referenced dietary supplement grade APIs to aseptically produce ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026. 2) On July 16, 2026, your firm used the following dietary supplement grade APIs to aseptically produce B COMPLEX (MDV) DEXPAN/NIACINAMIDE/PYRIDOX …

    Contains “aseptic*”Read the Form 483 →

  10. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 2

    Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, on August 31, 2026, the following deficiencies were observed on your firm's (b) (4) ISO 5 Laminar Airflow Hood: (b) (4) Caulking material was observed applied along the frame edges of the HEPA filter housing within your Laminar Airflow Hood (LAFH). The caulking exhibited the following defects: Uneven and irregular …

    Contains “ISO 5”Read the Form 483 →

  11. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 3

    Personnel were observed manually contacting the inner surface of a sterile container or closure. Specifically, the following observations were made: 1) During the aseptic production on August 31, 2026 of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026, the following aseptic processing techniques were directly observed: Your …

    Contains “aseptic*”Read the Form 483 →

  12. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 4

    The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air. Specifically, Your firm's (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH) is designed in a manner that potentially exposes sterile drug products and sterile containers/closures to air of a lower than ISO 5 classification. For example, I observed an air intake vent is located directly behind the sterile technician's …

    Contains “ISO 5”Read the Form 483 →

  13. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 6

    Failure to conduct post-use (b) (4) testing on (b) (4) used to sterilize drug products. Specifically, but not limited to, the following examples were observed: ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026, Qty (b) (4) - No documented (b) (4) test was found in the batch record for this lot. ELECTRO B COMPLEX (MDV) MAGNESIUM …

    Contains “sterili*”Read the Form 483 →

  14. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 7

    Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, the following deficiencies were observed: The sterile technician failed to clean the sides and back surfaces of the (b) (4) located inside of the ISO 5 LAFH. The sterile technician failed to clean in between the grates of the vent located (b) (4) the (b) (4). These deficiencies were observed on the following occasions: …

    Contains “sterili*”Read the Form 483 →

  15. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 8

    Lack of routine environmental monitoring in the ISO 5 area and classified areas. Specifically, the following deficiencies were observed: 1) Absence of Historical Surface Sampling Data - Your firm was unable to provide surface sampling environmental monitoring data for your ISO 5 Laminar Airflow Hood (LAFH) and classified cleanrooms prior to July 29, 2026. Despite this absence of surface sampling data, between June 5, 2026 and July 28, 2026, your …

    Contains “ISO 5”Read the Form 483 →

  16. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 9

    Sterile drugs and Materials were exposed to lower than ISO 5 quality air. Specifically, sterile wipes used to disinfect your firm's (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH) were staged open and exposed to lower than ISO 5 quality air prior to use. On August 31, 2026, sterile wipes were observed staged open and exposed on a (b) (4) in the ISO 7 cleanroom. These wipes were subsequently used to disinfect the firm's (b) (4) ISO 5 (b) (4) …

    Contains “ISO 5”Read the Form 483 →

  17. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 10

    Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, the following deficiencies were observed: Media Fill Volume Does Not Represent Worst-Case Production Conditions - According to your firm's media fill records, your firm (b) (4) of solution and fills [illegible] control vials during media fills. However, your firm's personnel stated that …

    Contains “media fill*”Read the Form 483 →

  18. Victory Medical Center PharmacyInspection ended Sep 10, 2026 · FEI 3010485868 · Observation 11

    Smoke studies were not performed under dynamic conditions. Specifically, your firm failed to perform airflow visualization (smoke study) testing under dynamic operating conditions for your (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH), which is used for the preparation of sterile drug products. No smoke study videos or written protocols exist demonstrating that airflow visualization testing had been performed under dynamic conditions in the …

    Contains “smoke stud*”Read the Form 483 →

  19. Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 3

    Microbial contamination was present in the ISO 5 area and areas adjacent to production areas. Specifically, during my review of your firm's environmental monitoring (EM) records, I found the following deficiencies: A. During a review of your firm's 2025 (b)(4) EM monitor sampling of the ISO Classified Cleanroom Suite I found two (2) different occurrences where 1 CFU was found during ISO 5 LAFC surface sampling (Acceptance Limits ISO Class 5: …

    Contains “ISO 5”Read the Form 483 →

  20. Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 4

    Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, during compounding observations of your firm's technicians, I observed your firm's technicians reaching over open vials while filling and stoppering filled sterile vials using their sterile gloved hands in the processing of sterile finished drug products, Tirzepatide 30mg/B12 0.5mg/mL (2.4mL) …

    Contains “aseptic*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.