Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 5
… Cleanroom ISO 7 Buffer Room contains 2 ISO 5 LAFCs used in the compounding of sterile drug products. Cleanroom Suite has been operational since February 2026.
Contains “ISO 5”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 6
… I found what appeared to be white foreign particulates on the floor within your firm's ISO 8 gowning room of Cleanroom Suite along with the vent remaining in the open position directly in front of the outside shoe storage rack.
Contains “gown*”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 7
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, I found during aseptic processing involving stoppering and capping using sterile gloves, your firm's technicians were using a (b)(4) disrupting unidirectional airflow within (b)(4) ISO 5 LAFC units within Cleanroom Suites (b)(4) during the processing of sterile drug …
Contains “unidirectional*”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 9
Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. Specifically, A. Your firm's technician was observed failing to disinfect components located within the ISO 7 Buffer Rooms (b)(4) prior to placing them into the ISO 5 LAFC unit. B. Your firm's technicians in both ISO 7 Buffer Rooms suites during the aseptic processing of the sterile drug products, Tirzepatide 30mg/B12 0.5mg/mL …
Contains “ISO 5”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 10
Inadequate testing on (b)(4) used to sterilize drug products. Specifically, during a review of your firm's (b)(4) test of (b)(4) used in the compounding of finished drug sterile products, your firm failed to use calibrated gauge(s) and equipment to ensure adequate testing and (b)(4) were capable of meeting their intended use.
Contains “sterili*”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 12
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, your firm failed to provide adequate rational evidence in support that media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
Contains “media fill*”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 13
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, on 8/19/2026, two (2) technicians were observed donning their sterile gowns to enter the ISO 7 Cleanroom to start aseptic processing. Sterile gowns worn by both technicians contacted the floor while donning rendering the gowns non-sterile. Additionally, poor sterile gloving techniques were found inadequate by the …
Contains “gown*”Read the Form 483 →
Greenwich RxInspection ended Sep 9, 2026 · FEI 3043120213 · Observation 14
Smoke studies were not performed under dynamic conditions. Specifically, A. Your firm's PIC and cleanroom manager, reported that they neither received, reviewed, nor approved any static or dynamic smoke studies for either Cleanroom Suites (b)(4) following (b)(4) original certifications or recertifications since the firm began operating in June 2025 for the cleanrooms. B. Your firm's compounding manager reported that no smoke studies during media …
Contains “smoke stud*”Read the Form 483 →
STAQ Pharma IncInspection ended Sep 8, 2026 · FEI 3015144909 · Observation 1
… On August 27, 2026, I observed standing water on top of non-impervious flooring within the mezzanine immediately above ISO-7 (b)(4) Laminar Airflow Production Room (Room (b)(4)), which contains an ISO-5 (b)(4) Workstation, (b)(4) Series. Subsequent inspection revealed notable staining on the back side of five (5) cleanroom tiles. This condition was present during the production of Fentanyl Hydrochloride 160 mcg/mL 50 mL Syringes, Lot 26166677A.
Contains “laminar*”Read the Form 483 →
STAQ Pharma IncInspection ended Sep 8, 2026 · FEI 3015144909 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not. Specifically, on September 1, 2026, Sterile Filling Technician [illegible] was observed in ISO-7 [illegible] Production Room 26102671A, at an ISO-5 (b)(4) Laminar Air Flow Workstation. While exchanging an environmental monitoring (EM) active air sample plate, [illegible] was observed extending her arms fully into the hood, up to her …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, A. Your firm conducted Airflow Visualization (AFV) studies (smoke studies) for ISO 5 Laminar Flow Hood (LFH) and Laminar Flow Hood (LFH) under both static and dynamic conditions in August 2025 and February 2026. No formal study reports or supporting …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 2
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Sterility test failure investigations for aseptically re-packaged Avastin 1.25 mg/0.05 mL were inadequate and failed to identify probable root causes. Since October 2025, the firm has rejected four batches due to sterility …
Contains “sterili*”Read the Form 483 →
RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 3
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, A. Personnel and material flow into and out of the ISO 7 and ISO 8 classified areas occurs through a single shared pathway that passes directly through the visual inspection and labeling room. Gowning, degowning, and material transfer — including finished product exiting the cleanroom and incoming …
Contains “gown*”Read the Form 483 →
RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 4
There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation. Specifically, A. Your firm's cleaning procedure is inadequate. i. Your firm stated that only the ISO 5 laminar flow hood receives cleaning (b)(4). However, your firm failed to clean the ISO 7 classified area (b)(4) leaving cleaning to the end of production …
Contains “ISO 5”Read the Form 483 →
OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 1
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, (A) The firm's environmental monitoring procedure does not require viable environmental monitoring during the initial aseptic setup of the (b)(4) filling line within the (b)(4) or during the initial aseptic setup of the (b)(4) automated filling machine positioned under [illegible] HEPA-filtered unidirectional airflow enclosure. Per …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, (A) Your firm has not adequately demonstrated that (b)(4)-sterilized machine (b)(4) parts and accessories used in aseptic filling maintain their sterile state during the established (b)(4) sterilization hold time in a controlled, non-classified area. The supporting microbiological evaluation …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 3
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. Specifically, (B) Batch record review of Myer's Cocktail (Lot #G27A05-26, Exp. 26 Nov 2026) revealed that equipment set-up of the (b)(4) filling line, located inside the ISO 5 (b)(4) in Suite (b)(4) began on 30 July 2026 at 08:01 and was completed by Sterile Tech at 08:06 on 30 …
Contains “ISO 5”Read the Form 483 →
OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 6
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (A) Your firm utilizes (b)(4) QA-access-controlled cabinets for the storage of sterilized machine (b)(4) parts and accessories. During inspection of these cabinets (b)(4) components, including a stopper bowl that directly contacts product stoppers, were observed without sterilization-status …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 1
Personnel performed aseptic manipulations with exposed hair or skin. Specifically, on August 24, 2026, while filling/stoppering lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL, we observed one of the operators working in the ISO 5 laminar flow hood with exposed skin on her forehead. The operator was observed entering the ISO 5 LFH, leaning over the bag of sterilized stoppers within the ISO 5 LFH, and placing stoppers on the recently …
Contains “aseptic*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 2
A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness. Specifically, from July 10, 2026 to August 21, 2026, your system for measuring pressure differential in the cleanrooms indicates negative pressure between the ISO 7 Buffer Room where the ISO 5 Laminar Flow Hoods are located and the ISO 8 Ante Room. The specification is (b)(4) w.c. and every data point documented in this …
Contains “ISO 5”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.