Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 3
Inadequate (b)(4) testing on (b)(4) used to sterilize drug products. Specifically, your firm is not conducting (b)(4) testing ((b)(4)) appropriately as recommended by the (b)(4) manufacturer. Your firm has not identified an appropriate (b)(4), you attach (b)(4) agent and you do not (b)(4) the (b)(4) before testing. [illegible] to one end of the (b)(4) and attach the other end of the (b)(4) to a (b)(4). You [illegible] the (b)(4) in (b)(4) (b)(4) …
Contains “sterili*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 5
Microbial contamination was present in the ISO 5 area. On August 3, 2026, your firm recovered 1 CFU in the ISO 5 Laminar Flow Hood (b)(4) (viable surface sample) after the filling/stoppering of lot #TZN-080326-20/2-2 of Tirzepatide/Niacinamide 20/2 mg/mL (2mL vial). No investigation was performed as your firm's action level for ISO 5 areas is (b)(4) CFU, which is not appropriate. The lot was released and has been partially distributed.
Contains “ISO 5”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 6
The facility is designed and/or operated in a way that permits poor flow of personnel or materials. Specifically, technicians enter the ISO 8 cleanroom area via a door from the unclassified (b)(4) area. Gowning occurs in the ISO 8 area, including washing of hands, on the "clean" side of the demarcation line. There is no designated room or area for gowning. Employees who are gowned and not gowned can interact in the same space while gowning. After …
Contains “gown*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 7
Sterile drugs were exposed to lower than ISO 5 quality air. Specifically, on August 24, 2026, we watched the filling and stoppering of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL. Your practice is to place the sterile stoppers onto the filled vials using (b)(4) and then pressing down on the stoppers with your (b)(4) to push the stopper into the vial. You then (b)(4) of the vials with (b)(4) (b)(4) the (b)(4) and take them out of …
Contains “ISO 5”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 8
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, typical batch sizes for Semaglutide/Niacinamide and Tirzepatide/Niacinamide drug products are (b)(4) vials. Vial sizes can range from 1mL to 5mL for GLP1 products and up to 10mL for other drug products. Production includes (b)(4) the drug product into a sterile (b)(4), and then manually …
Contains “media fill*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 12
Sterile products were exposed to non-sterile or non-depyrogenated supplies. Specifically, your firm does not sterilize/depyrogenate the glass beakers, (b)(4) graduated cylinders, and stir bars used to make sterile drug products. On August 24, 2026, we watched the preparation of lot #SMN-082426-5/2-5 of Semaglutide/Niacinamide 5mg/2mg/1mL. The glass beakers, (b)(4) graduated cylinders and stir bars were not sterilized/depyrogenated before use.
Contains “depyrogen*”Read the Form 483 →
Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 13
Biological indicators were not used to verify the adequacy of the sterilization cycle. Specifically, your firm has not validated nor do you use a biological indicator (BI) when (b)(4) the (b)(4) and (b)(4) used in the preparation of sterile drug products. The (b)(4) are used to place sterile stoppers onto the filled vials. (b)(4) are used to (b)(4) the (b)(4) of sterile water used in the formulation of sterile drug products.
Contains “sterili*”Read the Form 483 →
TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 1
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (b) (4) operational/dynamic certification of the (b) (4) Vial Filling, Stoppering and Sealing Machine, ISO 5 (b) (4) Filling Line cleanroom suite does not represent routine production operations. For example, ISO 5 Filling Line was not fully assembled or in-operation, and there was one …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, Autoclave Qualification and routine monitoring of the (b) (4) equipment ID #PE001, is deficient. A. There is inadequate written justification to place (b) (4) in the (b) (4) of the (b) (4) as the only process verification for routine sterilization loads. The rationale for the location of …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 3
… Operators use (b) (4) [illegible] reusable product-contact parts and (b) (4) sterilize injectable drugs on ISO 5 Filling Line. C. The (b) (4) System is not sampled or tested for conformance with any written specifications for chemical, microbiological, or physical attributes. D. [illegible] step which was the beginning of the distribution line is closed. (b) (4) remains stagnant in the (b) (4) System, ambient temperature (b) (4) distribution …
Contains “sterili*”Read the Form 483 →
TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 5
… Manufacturing personnel do not (b) (4) test the (b) (4) attached to ISO 5 Filling Line. There is no scientific justification for the (b) (4) replacement interval for this point-of-use nitrogen (b) (4). E. The firm did not conduct ID tests or any other analyses on Ultra High Purity (UHP) Nitrogen, lot (b) (4) accepted based on supplier COA. This is a product-contact gas used during production of Bupivacaine Hydrochloride 0.5%/Epinephrine …
Contains “ISO 5”Read the Form 483 →
STAQ Pharma of Ohio LLCInspection ended Aug 19, 2026 · FEI 3025336457 · Observation 3
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, Media fills or aseptic process simulations performed do not closely simulate actual production conditions or represent all syringe configurations. In addition, operators were not qualified prior to the introduction of new gowning components to ensure that …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 1
There is a lack of HEPA-filtered air and an inadequate HEPA filter coverage or airflow over the critical area to which sterile drug product is exposed. Specifically, on (b)(4), after the manufacture of tirzepatide for injection 26 mg/ml lot 08052026(b)(4) and tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4), the (b)(4) (b)(4) laminar flow hood (ISO-5) was operating with a pressure gauge reading of zero, indicating a …
Contains “laminar*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 2
The Cleanroom areas contain dust-collecting overhangs without adequate and frequent cleaning. Specifically, on 08/05/2026, visible dust was observed on the inside of the clean room door windowpane adjacent to the (b)(4) ISO-5 (b)(4) laminar flow hood in the non-hazardous compounding cleanroom which is used to produce sterile non-hazardous drug products. Throughout the cleanroom suites, doors and viewing windows feature decorative molding with …
Contains “ISO 5”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 3
Inadequate (b)(4) on (b)(4) used to sterilize drug products. Specifically, on (b)(4) after the manufacture of tirzepatide for injection 26 mg/ml lot 08052026(b)(4) and bulk tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4) we observed that the (b)(4) was not performed since the gauge used to test the (b)(4) appeared to be out of calibration and stuck on the pressure reading of approximately 18 PSI. This resulted in the …
Contains “sterili*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 4
… This reprocessing combined the contents of (b)(4) approximately (b)(4) bulk drug vials which were then (b)(4) and tested for endotoxin and sterility. This reprocessing was performed on (b)(4) and the beyond use date assigned was 9/19/2026.
Contains “sterili*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 5
Smoke studies were inadequately performed under dynamic conditions. Specifically, the smoke studies taken on 1/27/2025 in your ISO-5 (b)(4) laminar flow hoods and bio safety cabinets did not fully demonstrate laminar flow. These smoke study videos were 4 to 18 seconds long and recorded by (b)(4). The video does not show the air flow over the critical sterile drug product preparation areas and the air flow patterns for hoods that are located …
Contains “smoke stud*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 7
… Specifically, the ante room gowning includes use of non-sterile lab personnel protective equipment including shoe covers, a short lab coat, hair net, face mask, hand washing, non-sterile gloves, and use of (b)(4) or (b)(4) disinfectants for the gloved hands. There is no method for detecting and controlling cross contamination such as swabbing and analytical lab testing for particles, lead particles, and other chemicals.
Contains “gown*”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 8
Lack of and Inadequate routine environmental monitoring in the ISO 5 area and classified areas. Your staff stated they perform (b)(4) surface sampling within the ISO 5 and ISO 7 area after cleaning and disinfection. Sampling after cleaning does not accurately represent your production environment. Additionally, your staff also stated and demonstrated that when (b)(4) plates are unavailable, the firm's procedure is to use (b)(4) (b)(4), (b)(4) on …
Contains “ISO 5”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 9
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, on 08/06/2026 during cleaning activities of the (b)(4) laminar flow hood ISO 5 (b)(4) in cleanroom (b)(4), the upper torso of a pharmacist was observed entering the ISO 5 hood, disrupting the unidirectional airflow intended to protect the sterile field.
Contains “aseptic*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.