Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 3
… Batch (b)(4) filling process was a forceps used to remove debris from a vial (b)(4), with an (b)(4) used in the process extending over open vials, breaking first air. SOP-07637, "Aseptic Procedure for (b)(4) Aseptic Technique for Filling (b)(4)" v3.0, Effective date 14 June 2024, Section 7.4.7 indicates personnel should avoid reaching over any open or partially (b)(4) vials during aseptic production operations as much as possible, to avoid …
Contains “first air”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 5
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm is unable to use some (b)(4) (b)(4) without breaking first air to open vials. For example, (b)(4) on the (b)(4) (b)(4) which your firm uses for routine interventions during the filling process for sterile drug product (b)(4), cannot be introduced into the (b)(4) …
Contains “first air”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 6
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, on 6/1/2026, a divot approximately two to four inches long was observed approximately one foot off the ground on the corner of a wall pillar in ISO-5 Room 149A Sterile Staging, Building 25 Commerce, immediately next to the exit door of the (b)(4) oven. Similarly, on 6/2/2026, a floor divot approximately one inch in …
Contains “ISO 5”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 1
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, On 5/27/2026, the operator was observed conducting aseptic manipulations in which the movement of first air in the ISO 5 LAFH was blocked during the aseptic production of the following sterile drug products: • Sodium Phosphate 15 mmol in Dextrose 5% 100 mL, Order ID: naphos052726, BUD 06/06/2026 • …
Contains “aseptic*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 2
Personnel performed aseptic manipulations with exposed hair or skin. Specifically, On 5/27/2026, during the aseptic production of the following drug product: • Ondansetron 8 mg, Dexamethasone 12 mg in Sodium Chloride 0.9% 50 mL, Order ID: 83618268, BUD 5/27/2026 I observed your operator's head and face enter the ISO 5 LAFH located in the non-hazardous Oncology suite without adequate protective gowning. The skin surrounding the operator's forehead …
Contains “aseptic*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 3
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, On 06/02/2026, during aseptic production operations, an operator was observed moving quickly within ISO 5 LAFH while performing aseptic manipulations. At the time of the observation, the operator had an exposed, filled syringe of sterile drug product in hand. Rapid …
Contains “unidirectional*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 4
Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. Specifically, On 5/28/2026, during the aseptic production of the following drug products: • Daptomycin (Cubicin) 750 mg/NS 50 mL, Order ID: 84305997, BUD: 05/30/2026 • Cefepime/Sodium Chloride 0.9% 50 mL, Batch: 052826FS1, BUD: 06/12/2026 • Bumetanide 3 mg in Dextrose 5% 50 mL, Order ID: 84299952, BUD: 05/29/2026 • Acyclovir 600 mg …
Contains “aseptic*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 5
Smoke studies were inadequately performed under dynamic conditions. Specifically, your firm failed to adequately perform smoke studies under dynamic conditions to demonstrate unidirectional airflow, simulate aseptic production, simulate worst-case conditions including all components, materials, and equipment present during actual or routine aseptic operations, and an adequate air quality environment within your ISO 5 critical areas. The following …
Contains “smoke stud*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 6
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, your operator failed to disinfect the (b)(4) machine between aseptic production operations. For example: On 5/27/2026 during the aseptic production of the following drug products, the operator failed to disinfect the (b)(4) machine between aseptic production operations: • Sodium Phosphate 15 mmol in Dextrose 5% 100 mL, Order …
Contains “sterili*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 7
… This room contains an ISO 5 classified LAFH used to produce sterile drug products. • Protruding Sprinkler Head - In-Patient Pharmacy ISO 7 Classified Cleanroom (Hazardous) - A protruding sprinkler head was observed in the ceiling of the In-Patient Pharmacy ISO 7 classified cleanroom used to produce sterile hazardous drugs. The sprinkler head is located directly above the ISO 5 classified LAFH. The sprinkler head is not on a routine cleaning …
Contains “ISO 5”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 8
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, your firm's media fill protocol does not closely simulate the manipulations, container/closure configurations, or fill volumes used during actual production operations. For example, During actual production, operators use syringe(s) to admix drug product into prefilled bags, sometimes …
Contains “media fill*”Read the Form 483 →
Lt Col Luke Weather Jr Veterans Affairs Medical CenterInspection ended Jun 4, 2026 · FEI 1074265 · Observation 9
Materials were exposed to lower than ISO 5 quality air. Specifically, on 5/28/2026, I observed sterile wipes stored on a counter across from ISO 5 LAFH within the ISO 7 classified cleanroom. The wipes were opened and exposed to ISO 7 air quality and were subsequently used to clean and disinfect the surfaces of the ISO 5 LAFH. According to staff, the wipes are stored in the ISO 7 environment until contents are fully depleted. Drug products …
Contains “ISO 5”Read the Form 483 →
Annovex Pharma IncInspection ended Jun 3, 2026 · FEI 3020928491 · Observation 1
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, your firm failed to ensure that the laminar airflow hoods used for the production of sterile and non-sterile drug products were maintained in a state of adequate control. In a cleanroom certification conducted on January 28, 2026, all (b)(4) laminar airflow hoods at your facility were found to be operating …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, Media Fills A) Your facility failed to follow written procedure S601002, entitled "Validation of Aseptic Processes by Simulation (Media Fill)" version 12 dated 12/02/2025 that requires you to revalidate the media fill process with [illegible] runs if you obtain a turbid …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 2
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm has not established adequate procedures and controls for the maintenance, certification, and qualification of HEPA filters, laminar air flow hoods (LAFH), biological safety cabinets (BSC), and cleanroom HVAC systems used for sterile drug production. HVAC failures …
Contains “laminar*”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 3
… Examples of these occurrences include but are not limited to: A) DEV2025047, initiated on 07/02/2025 in response to a turbid media fill unit from lot (b)(4) identified "operator error" as the root cause without evaluating potential impacts of other process inputs such as gowning, material sterility and handling, and environmental controls. Additionally, the root cause was attributed to an individual based on speculation, without an established …
Contains “media fill*”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 4
Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained. Specifically, A) During post-use (b)(4) of the sterilizing (b)(4) used for prednisolone sodium phosphate 1% / moxifloxacin HCl 0.5% / bromfenac 0.09% PF, Lot PMB121525CH BUD 12/15/2026, two (2) consecutive tests resulted in the error message "Error: (b)(4) Not Obtainable"; neither were recorded in the batch …
Contains “sterili*”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 6
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed. Specifically, Visual Inspection Operations You have not ensured that operators conducting 100% (b)(4) visual inspection are capable of identifying all defined visible defects across your sterile drug product containers, including vials, syringes, and eye drop containers. This is evidenced by: A) During the …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Shilpa Medicare LimitedInspection ended May 29, 2026 · FEI 3018694237 · Observation 5
… Alarms generated for the (Production) (b) (4) (b) (4) and (Micro) including sterilization load cycles are not backed up and automatically overwritten (b) (4) by the system.
Contains “sterili*”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 3
Your master production and control records did not include a statement of action limits on radiochemical yield. Specifically, A. The manufacturing batch records for (b) (4) Injection do not include action limits on radiochemical yield. For example, Manufacturing batch record for PPQ batch # (b) (4) on page 3 of 26 Section, Final Product Vial Assay and Sterility Inoculations, the radiochemical yield is only recorded, however, there is no statement …
Contains “sterili*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.