Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 4
You lack personnel with the necessary background and training to perform their assigned functions. Specifically, On 05/19/2026, during a production mock preparation of final product vial subassembly conducted under the ISO 5 (b) (4) laminar airflow hood (LFH SN: (b) (4), the operator (b) (6), (b) (7) did not follow techniques described in SOP D0011940, Preparation of Final Product Vial Subassembly – (b) (4) (b) (4) Revision: Q, Effective Date: …
Contains “ISO 5”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 5
You did not implement procedures to ensure that all equipment is cleaned and suitable for its intended purposes that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. Specifically, You failed to monitor the pressure differential of ISO 5 Laminar Flow Hood (#(b) (4)), to ensure the pressure differential across the …
Contains “ISO 5”Read the Form 483 →
Fresenius Kabi USA, LLCInspection ended May 14, 2026 · FEI 3001833549 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, (A) The qualification (b) (4) used to qualify visual inspectors do not always include defect samples at the lower limits of visual detection established during threshold studies. For example, Test (b) (4) ((b) (4) vial), which was used to requalify visual …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 1
Smoke studies were inadequately performed under dynamic conditions. Specifically, Your firm did not conduct smoke studies under dynamic conditions, simulating worst-case production activities, including all components, materials, and equipment present during actual or routine aseptic operations, to demonstrate unidirectional airflow within the ISO 5 area(s) for the following equipment: 04/08/2026 - Hazardous [illegible] - Biologic Safety Cabinets …
Contains “smoke stud*”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 2
Beta-lactam drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, Beta-Lactam drug products are produced in the same ISO 5 hoods as non-beta-lactam drug products intended to be sterile. The following beta-lactam drugs were observed being produced in your LAFH hood include, but are not limited to: - ceftaroline fosamil 300 …
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 3
Contamination was observed in your production area. Specifically, On 04/29/2026, unidentified brown staining was observed on the HEPA filter in the ISO 5 non-hazardous LAFH production hood (SN: [(b)(4)]). Your firm was unable to identify the source of the staining or confirm whether it affected filter integrity, air quality, or aseptic conditions in the ISO 5 area. The duration of this condition is unknown.
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 4
… wipe down materials with an appropriate disinfectant (e.g., [(illegible)]) when transitioning those materials from the ISO 7 buffer room environment into the ISO 5 critical zone during the production of luspatercept-aamt 50 mg, label # [illegible]. B) On 04/28/2026, a re-purposed [(illegible)] bottle, labeled '[(illegible)]' used to discard leftover fluid generated during aseptic processing operations, was observed used within the ISO 5 critical …
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 5
An operator rested their arms on the work surface of the hood during aseptic production. This practice may introduce contamination into the ISO 5 work area. Specifically, A) In the non-hazardous production room [(6)(4)] operators were observed resting their hands directly on the ISO 5 workbench surface on 04/29/2026 during the production of micafungin 100 mg in normal saline 100 mL. B) On 04/28/2026, the operator's elbows were observed resting on …
Contains “aseptic*”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 6
Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, On 04/28/2026 during the production of bortezomib 2.7 mg, label # [illegible], an operator failed to sanitize or change their gloved hands with [(6)(4)] after touching the computer keyboard and mouse within the ISO 7 buffer room prior to …
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 7
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow. Specifically, An operator was observed spraying their gloved hands with [(b)(4)] under the ISO 5 hood and then rapidly moved their hands to dry within the critical area, causing disruption of unidirectional airflow on 04/28/2026 during the production of bortezomib 2.7 mg, label …
Contains “unidirectional*”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 8
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, A) The [(15)(4)] plate and washer located on the front grille of BSC SN: [(6)(4)] and [(15)(4)] (hazardous room [(b)(4)]) are difficult to clean and may harbor and shed particulates and microbial contamination into the ISO 5 environment. This screw and washer were left by the firm's engineering to the BSC grill …
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 9
Personnel performed aseptic manipulations with exposed hair or skin. Specifically, A) On 04/27/2026 and 04/29/2026, multiple operators were observed aseptically processing drug products intended to be sterile in the ISO 5 laminar airflow hood (LAFH) with exposed hair, including during the production of daptomycin 670 mg in sodium chloride 0.9%, 36.6 mL, label # [(15)(4)] in room [(6)(4)]. B) On 04/29/2026, one operator was observed inserting …
Contains “aseptic*”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 10
Materials were exposed to lower than ISO 5 quality air. Specifically, A) Sterile, lint-free wipes stored in an exposed, open condition were observed on the wall of the ISO 7 buffer rooms. At least [illegible] of the transparent boxes on the wall had broken hinges and were left open during production. The wipes, which were difficult to pull from the box, were sprayed with sterile [(b)(4)] in the ISO 7 buffer and then used to clean the ISO 5 …
Contains “ISO 5”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 11
Personnel engaged in aseptic processing were observed wearing non-sterile gloves. Specifically, Operators were observed using expired sterile gloves (manufactured in 01/2022) during aseptic production of bortezomib 2.7 mg, label # [illegible] on 04/28/2026. There is no assurance that the gloves are intact and remain sterile. Your sterile glove manufacturer suggested that the gloves be used within [illegible] of the manufacturer date.
Contains “aseptic*”Read the Form 483 →
QuVa Pharma IncInspection ended May 4, 2026 · FEI 3012053582 · Observation 1
Procedures designed to prevent microbiological contamination of [illegible] are not established, written and followed. Specifically, your firm failed to adequately establish procedures to prevent microbiological contamination of drug products purporting to be sterile. For example, A. Your firm failed to adequately define a [illegible] used by technicians to pick items off cleanrooms. The device storage location technicians hang the device on the …
Contains “purporting to be sterile”Read the Form 483 →
QuVa Pharma IncInspection ended May 4, 2026 · FEI 3012053582 · Observation 2
… IR-12512 (DEV-02984) documented Nov 2024, prior to compounding Fentanyl Citrate PF 50 mc 10138352, Expiry 02/12/2025 compounding in ISO 7 Cleanroom Suite 7, ISO 5 LAFH numbered [illegible], your compounding technician found on the ISO 5 LAFH grate in front [illegible] a brown to black foreign residue contaminant, later within an investigation identified [illegible]. The sealant [illegible]. The sealant is applied during the HEPA filt[er] …
Contains “ISO 5”Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process. Specifically, A. Scientific evidence could not be provided demonstrating the source of the smoke used during your air flow visualization studies is neutrally buoyant. During your review of smoke study videos in your aseptic filling lines in workshops (b) (4) as well as the (b) (4) …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 2
… While observing filling of batch (b) (4) of (b) (4) Injection, USP, on 20Apr2026, I observed the (b) (4) governing the (b) (4) RABS to be (b) (4) at approximately 12:40pm, and took a photo of the (b) (4) I inquired about the status of the (b) (4) after 1:00pm. The firm initiated an investigation which determined the tube was cracked in the (b) RABS which is connected to the (b) (4) The investigation stated the reading of the (b) (4) was within …
Contains “RABS”Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 3
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. A. Inadequate aseptic technique was observed in the review of videos and while watching the aseptic filling of (b) (4) Injection in workshop (b) (4) on 20Apr2026. Discrepancies include: 1. Operators block first air during the addition of stoppers. This was seen in workshops (b) (4) (b) (4) aseptic filling lines. 2. An …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, the following discrepancies were noted during review of the environmental monitoring program: A. Not all (b) (4) used during aseptic filling of injectable products are sampled at the end of the batch. C-VP-206-71000-2617 Risk Assessment of Environmental Control in Workshop (b) (4) specifies sampling of (b) (4) to monitor after batch …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.