Fresenius Kabi USA, LLC Form 483, May 2026
FDA issued this Form 483 to Fresenius Kabi USA, LLC in New York (FEI 3001833549) at the end of an inspection that ended May 14, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 14, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Oct 20, 2026
- 159 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate visual inspection process controls
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, in 2024 your firm conducted studies to qualify the defect standards for your visible particulate container challenge [illegible]. However, you failed to assess the appropriateness of your current (b) (4) sterile vial inspection process after these Visual Inspection Method Qualification studies revealed significant degradation in visual inspection quality and capabilities when the vials were inspected by the (b) (4) method compared to 100% manual visual inspection. Your firm's current (b) (4) visual inspection process entails vials which are presented to inspectors via a conveyor system at pre-determined speeds (without ever determining how conveyor speed impacts visual inspection performance). For example: 1. Protocol #US-PU-1027-MVD-EQP-000116815 (Determination of Probability of Detection (b) (4) with (b) (4) Fill of (b) (4)), initiated in 8/2024. Examples of results from 100% manual inspection vs. the firm's current (b) (4) inspection, are as follows: a. (b) (4) stopper particulate (Unit ID: (b) (4)): 93.3% vs. 10.0% b. (b) (4) stopper particulate (Unit ID: (b) (4)): 83.3% vs. 0.0% c. (b) (4) fiber particulate (Unit ID: (b) (4)): 70.0% vs. 13.3% d. (b) (4) particulate (Unit ID: (b) (4)): 70.0% vs. 13.3% 2. Protocol #US-PU-1027-MVD-EQP-000122295 (Determination of Probability of Detection, (b) (4) with (b) (4) Fill of (b) (4)), initiated 10/2024. Examples of results from 100% manual inspection vs. the firm's current (b) (4) inspection, are as follows: a. (b) (4) stopper particulate (Unit ID: (b) (4)): 83.3% vs. 43.3% b. (b) (4) stopper particulate (Unit ID: (b) (4)): 80.0% vs. 20.0% c. (b) (4) stopper particulate (Unit ID: (b) (4)): 96.7% vs. 36.7% d. (b) (4) stopper particulate (Unit ID: (b) (4)): 86.7% vs. 40.0% e. (b) (4) fiber (Unit ID: (b) (4)): 73.3% vs. 33.3% f. (b) (4) fiber (Unit ID: (b) (4)): 80.0% vs. 16.7% g. (b) (4) fiber (Unit ID: (b) (4)): 73.3% vs. 33.3% h. (b) (4) fiber (Unit ID: (b) (4)): 73.3% vs. 23.3%
- 2
Inadequate aseptic and sterilization process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, (A) The qualification (b) (4) used to qualify visual inspectors do not always include defect samples at the lower limits of visual detection established during threshold studies. For example, Test (b) (4) ((b) (4) vial), which was used to requalify visual inspector on 1/21/2026, contains (b) (4) accept units and [illegible] defect units. Of the (b) (4) defect units, [illegible] contain foreign material particulates of the following types and sizes: (b) (4). Your threshold study established a PoD of [illegible] (b) (4)% for (b) (4) ((b) (4) stopper) particulates; however, defects at this size are not represented in Test (b) (4) and (B) [illegible] for airflow visualization (C) Your firm uses fog generated from (b) (4) studies in cleanrooms, including sterile drug product filling lines. However, Study/CC # (b) (4) 26-016.V6, conducted on March 13, 2026, does not provide adequate evidence that the fog is neutrally buoyant. Video observations show the fog was discharged upward in bursts, reversed direction, and fell back. Your (b) (4) Sterilization Qualification Study #(b) (4) 17-025 for the (b) (4) vial established a minimum validated Fo of (b) (4) at the worst-case location. However, per SOP US-PU-1027-SOP-OT-000096908, Operation and Release Criteria for (b) (4), the accepted Fo value at end of cycle is (b) (4), as permitted by your SOP, is sufficient to achieve adequate sterilization for value as low as (b) (4). You have not demonstrated that an Fo (b) (4) the (b) (4)
- 3
Deficient analytical method transfer verification
Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use. Specifically, your firm does not perform comparative testing for all in-house analytical method transfer studies that compare analytical results between the transferring lab and your receiving lab to determine a successful method transfer. For example, you did not compare the results of the transferring lab with the results of your receiving lab for the transfer of the external labs in-house method ((b) (4)) for the Determination of Impurities in (b) (4) Injection ((b) (4)) from (b) (4) to FK Grand Island, executed under Protocol: NAM-MVD-FG-000111207.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3001833549, newest first.
- Form 483, July 2011Inspection ended Jul 8, 2011 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.