Skip to content

Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 5

    Your firm failed to establish an adequate system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Discrepancies were noted during the cleaning performed on 20Apr2026 in workshop (b) (4) after the manufacture of (b) (4) Injection-USP including: A. Operators were seen kneeling on the (b) (4) as well as reaching over and leaning on equipment during cleaning. B. Using the same cloth to clean numerous pieces of …

    Contains “aseptic*”Read the Form 483 →

  2. Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 6

    Routine calibration, inspection, checking of automatic, mechanical, electronic equipment is not performed according to a written program designed to assure proper performance. The following discrepancies were noted during the review of the (b) (4) weight check systems on aseptic filling lines in workshops (b) (4) A. Workshop (b) (4) The weight checks performed on the (b) (4) balances prior to use, do not bracket the amount being weighed. The …

    Contains “aseptic*”Read the Form 483 →

  3. Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 7

    Control procedures are not established that describe in process controls which validate the performance of those manufacturing processes that may be responsible for causing variably in the characteristics of in-process materials and the drug product. A. Your firm failed to validate the in-process inspection method to evaluate (b) (4) of aseptically (b) (4) Injection. (b) (4) (b) (4) • Currently you use (b) (4) but provided no documented evidence …

    Contains “aseptic*”Read the Form 483 →

  4. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, A. During filling of (b) (4) on the (b) (4) line for protocol DMF/MSP/26/016 "Protocol for filling of (b) (4) in (b) (4) mL (b) (4) Bottle in (b) (4) Bottle)" Filling line, poor aseptic practices were observed: 1. An operator was observed breaching first air by reaching over open sterile bottles …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  5. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 2

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, Aseptic processing operations fail to provide adequate protection of Grade A (ISO Class 5) environments and first air over critical exposure points. For example: A. Rooms (b) (4) (Vial Filling and Sealing) and (b) (4) Filling): Grade A (b) (4) laminar airflow areas are separated from Grade …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  6. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 3

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, airflow visualization studies (smoke studies) do not demonstrate appropriate airflow patterns. Additionally, airflow visualization studies and media fills fail to represent actual commercial manufacturing conditions: A. Your airflow visualization studies do not include …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  7. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 4

    … Your current procedure states that extrinsic particulates indicating filth, sterility assurance issues, or cGMP violations are unacceptable even if statistical sampling criteria are met. However, without characterization, you cannot determine if particles are extrinsic. For defect types without established alert limits (glass particles, fibers when tracked separately, broken/cracked vials), no investigation is triggered and particles are never …

    Contains “sterili*”Read the Form 483 →

  8. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 5

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, or followed. Specifically, personnel monitoring procedures for aseptic operations are inadequate. The finger dabbing method consisting of touching the plate with four fingers together instead of rolling each finger separately was observed on the following occasions: A. April 9, 2026: During the setup for sterile …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  9. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 6

    Written procedures for qualifying, controlling, and evaluating suppliers and materials used in aseptic processing areas are not established, written or followed. Specifically, your firm lacks a comprehensive, risk-based program for qualifying and monitoring suppliers of critical consumables used in ISO 5 (Grade A) areas, including garments, (b) (4), wipes, and disinfectants. Your firm relies solely on supplier Certificates of Analysis without …

    Contains “aseptic*”Read the Form 483 →

  10. Lonza Biologics, Inc.Inspection ended Apr 16, 2026 · FEI 3001451441 · Observation 1

    Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, your firm has not demonstrated a state of control over the CASGEVY manufacturing process: a) (b)(4) Aseptic Process Simulation (APS) runs were executed from (b)(4) in Grade (b)(4) suites (b)(4). APS runs …

    Contains “aseptic*”Read the Form 483 →

  11. Lonza Biologics, Inc.Inspection ended Apr 16, 2026 · FEI 3001451441 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, a) DEV-1358321 was initiated on 5/30/2025 for an identified trend of particulates (b)(4) for the CASGEVY manufacturing process. In response to this event, CAPA-1420656 was opened on 10/2/2025 for initiation of a (b)(4) for (b)(4) was created on (b)(4) to update (b)(4), the software for (b)(4) in-process monitoring …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  12. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process. Specifically, A. Smoke studies The review of the smoke study reports used to qualify the filling lines used in the aseptic filling of [redacted] API stated no obvious turbulence or reflux [redacted] Injection and [redacted] was observed. The following uneven air currents were not …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  13. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. A. Visual Inspection 1. Your firm uses only one defect kit for operator training, ongoing requalification, and performance testing. This kit contains only one example of each defect type. Some of the defects have been in use for over four years, allowing operators to repeatedly view, and are tested on identical defects …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  14. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 3

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the [system/equipment] to produce aseptic conditions. Specifically, discrepancies were noted during the review of the (b)(4) validation for the following areas: A. API - (b)(4) used in the aseptic filling of The (b)(4) cycle was observed taking place on the (b)(4) API on 13Apr2026. During this activity along with the review of the procedures (b)(4) …

    Contains “aseptic*”Read the Form 483 →

  15. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Environmental Monitoring 1. Adequate risk assessment could not be provided for changing viable surface monitoring from RABs, are (b)(4) located in the (b)(4) to (b)(4) These (b)(4) for the (b)(4) used to handle settle plates during environmental monitoring. 2. Recovery studies have not been performed that show using one swab (b)(4) of a (b)(4) …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  16. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 5

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. The following discrepancies were noted during review of the aseptic filling lines for the following: (b)(4) API (b)(4) 1. On April 9, 2026, I observed your firm failed to maintain equipment in a clean and orderly manner. The (b)(4) Sterile (b)(4) equipment (b)(4) was found to have the following …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →

  17. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 6

    … The mop heads are used to clean the ceilings, walls, and floors of the API refining room and the finished product filling room, directly outside of the Grade A areas. I observed the operator submerging the mop head repeatedly, at different angles, attempting to submerge the entire mop head prior to cleaning. 2. Cleaning of the grade B room did not follow the sequence of cleaning listed in PO-59 006, i.e. ceiling, walls, equipment surface, floor.

    Contains “Grade A”Read the Form 483 →

  18. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 7

    The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products. Your firm failed to ensure adequate oversight during the installation of a (b)(4) valve within a Grade A aseptic processing environment RABS equipment #(b)(4) on April 8, 2026. Quality Assurance personnel were observed to be positioned away from the operation with obstructed …

    Contains “Grade A”Read the Form 483 →

  19. Adimmune CorporationInspection ended Apr 2, 2026 · FEI 3008919998 · Observation 4

    Written operating procedures are not followed or are inadequate, specifically, a. On March 30, 2026, during observation of the Formulation process, we observed staff not regularly sanitizing their gloves as per procedure. Specifically, we observed the (b) (4) main manufacturing staff working (b) (4) laminar flow hood (b) (4) the hood without sanitizing. Section 7.3.3 of SOP (b) (4)S067 Good Aseptic Operation Practice states: "Sterile gloves …

    Contains “laminar*”Read the Form 483 →

  20. Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 1

    … You do not perform routine monitoring of your ISO-5 conditions. Currently, environmental monitoring (EM) of these conditions is limited to major activities such as (b) (4), passaging of (b) (4), and bulk fill operations. You do not have EM data to support "at rest" conditions. Furthermore, you have not performed a risk assessment or study to verify that your EM locations used for current sampling of these environments are suitable for collecting …

    Contains “ISO 5”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.