Skip to content

Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 10

    … Your firm does not conduct testing on conformity of containers and closures to ensure that the manufacturer's results are valid and reliable, including sterility of these containers and closures. 3. Your firm has never performed supplier audits on any of the raw materials received at your facility.

    Contains “sterili*”Read the Form 483 →

  2. Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 1

    … The recovered documents included, but were not limited to, executed production batch records; media preparation, incubation, and sterilization cycle logbook pages; finished product sample collection forms; environmental monitoring sample forms; and change control log forms. B. The Incubation Usage Log, Book Number (b)(4) Reference SOP: QCD-M/007 & III, contained (b)(4) entries (Serial Numbers (b)(4) through (b)(4)) that were signed by the analyst …

    Contains “sterili*”Read the Form 483 →

  3. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. During review of your firm's airflow visualization (smoke) study, document ID VFU315T, entitled. “Rokstudie modifiering ge ”. dated 2024/07/03. conducted on the filling line used to fill the ge we dug. the following was observed: 1. Your airflow visualization study is …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  4. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, Examples of poor aseptic behavior were observed during review of the aseptic process simulation study, media fill batch ey and batch ge on the ampoule line g) ey used to fill the ge drug ge. 1. During line set up for both media fill batches an operator was observed setting up the ge using …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  5. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your firm does not have a risk assessment to justify the environmental monitoring and personal monitoring locations and frequencies. 1. There is no surface monitoring on the Grade A aseptic filling line. ge used to fill the ge drug. While reviewing machine set up of the media fill dated September 15, 2025, and while observing …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  6. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 4

    The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing. Specifically, Batch records do not contain documentation of all interventions performed in the Grade A or the length of time taken to perform each intervention. Routine interventions not recorded include but are not limited to the following: a. Cleaning of b. Adjustment of …

    Contains “Grade A”Read the Form 483 →

  7. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 5

    … The aseptic filling line is not equipped with RABS technology or ge and is not fully enclosed on all sides. The front and back are partially covered with age that extends from the top of the line downward. The front ge stops approximately ge before the table that holds the filling line and the line is open from the end of this ge down to the table. 2. The ge (ampoule loading area) extends out of the Grade A into the surrounding Grade B room. …

    Contains “aseptic*”Read the Form 483 →

  8. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 9

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, there is no requirement for stratification or distinct timepoints throughout the filling process at which BET samples are to be collected. A single vial is randomly collected from each batch of ge and is used for Bacterial Endotoxin Testing (BET) per SOP 1525, “Kontrollomfattning Steril …

    Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →

  9. US Specialty Formulations LLCInspection ended Jan 14, 2026 · FEI 3010680515 · Observation 4

    … Your firm also has not performed container closure integrity validation. (E) The following discrepancies were observed in the 4 6 4 (Equipment~(b)( ~) and 6 Sarracenia purpurea 0.17 g/mL Injection : (i) The (6) (4) PQs were conducted with partial (b) (4 study. Validation has sterilization of Sarracenia purpurea 0.17 (ii) There is no documented rationale qualification to confirm drain behavior (iii) A three-run performance qualification (P …

    Contains “container closure integrity”Read the Form 483 →

  10. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 1

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards Specifically, Microbiologists responsible for performing sterility testing and collecting environmental monitoring, personnel monitoring, and (b)(4) samples confirmed they do not collect, test, and incubate all samples. A. During inspection of the (b)(4) Biological incubators …

    Contains “sterili*”Read the Form 483 →

  11. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 3

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Your firm aseptically fills OTC finished drug products (b)(4) for the US market. Your aseptic filling process includes: A. After sterilization of your (b)(4) product transfer vessel via (b)(4) performed in Washing and Sterilization Area (b)(4) you move this vessel into …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  12. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 4

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. A. On December 5th, 2025, while observing set-up on (b)(4) Filling Line (Room (b)(4)) for the aseptically filled finished drug product (b)(4) batch (b)(4) poor aseptic processing behavior was observed. This filling line is used to manufacture US market product. Examples of poor aseptic behavior include: …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  13. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 5

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Personnel monitoring program has not been implemented for any aseptic operations. Personnel monitoring regarding aseptic connections has never been conducted. B. Surface monitoring has never been performed on any equipment surfaces including critical product contact surfaces such as (b)(4) product contact locations including (b)(4). C. Active …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  14. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 6

    Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. A. You do not perform visual inspection of your aseptically filled product, and you have not established written procedures regarding this critical process. Your QA Manager reported you inspect the outside of each unit for …

    Contains “aseptic*”Read the Form 483 →

  15. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 1

    Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, A. During review of the bioburden and endotoxin tests performed on 11/03/2025 for the (b)(4) Line media fill (b)(4) samples, we found the following. a) The (b)(4) Tank and Tank Transfer Line samples endotoxin out of specification (OOS) results obtained on …

    Contains “media fill*”Read the Form 483 →

  16. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 4

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, During the inspection, we watched videos of airflow visualization studies (smoke studies) performed for the Ampoule Line (b)(4) dated 08/03/2025 and for the Vial Filling Line dated 05/08/2025. The above filling lines manufacture injectable products for the U.S. …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  17. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 6

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, Your firm lacked adequate justification for washing and sterilizing (b)(4) gloves only To (b)(4) is used. Also, (b)(4) is used as needed and (b)(4) (a sporicide) is used (b)(4). However, there is no written procedure on how to clean (b)(4) gloves. You also have no study to monitor cleaning …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  18. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 1

    The responsibilities and procedures applicable to the Quality Unit are not fully followed. Aseptic processing operations are not adequately designed to provide sufficient visual monitoring of critical interventions and aseptic manipulations to ensure compliance with current good manufacturing practice (CGMP) requirements. For example, during inspection of aseptic filling lines (b) (4) it was observed that multiple corrective interventions (b) (4) …

    Contains “aseptic*”Read the Form 483 →

  19. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, During aseptic filling operations, procedure EP2-PRD-SOP-002, "Personnel Behavior in Aseptic Area" and line specific intervention procedures were not followed: A. Aseptic filling on filling line (b) (4) Injection batch (b) (4) 1. On October 16, 2025, during line assembly and filling for ROW (b) (4) …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  20. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 3

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, airflow visualization (smoke studies) of Grade A laminar flow do not demonstrate there is appropriate air laminarity during commercial operations: A. (b) (4) Line Airflow Study (b) (4) Protocol #E2-MIS-VSP-0195, effective March 28, 2024, is not representative of actual …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.