Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 4

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. A. Aseptic processing operations conducted in filling line (b) (4) are deficient in design and controls to prevent microbiological contamination of sterile drug products. On November 05, 2025, we evaluated the filling operation in (b) (4) Line (b) (4) for (b) (4) Injection (b) g; Batch (b) …

    Contains “aseptic*”Read the Form 483 →

  2. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 5

    Aseptic processing areas deficient regarding system for monitoring environmental conditions. Your environmental monitoring program is inadequate in assessing and monitoring all the potential critical surfaces, conditions and equipment in your aseptic processing areas. A. Non-viable particle count (NVPC) (b) (4) monitoring in Grade B areas is performed only once during product batch activity as per step (b) (4) of procedure EP2-PLA-SOP-012-08, …

    Contains “aseptic*”Read the Form 483 →

  3. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 7

    Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals. Specifically, your firm relies exclusively on the vendor's Certificate of Analysis (COA) to ensure the sterility of (b) (4) used on filling line (b) (4) for (b) (4) Following an initial analysis conducted in March 2024, your firm has purchased over (b) (4) bottles of …

    Contains “sterili*”Read the Form 483 →

  4. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 9

    … Your operators began cleaning from the (b) (4) located in Grade A area and subsequently proceeding towards the filling zone without first cleaning and sanitizing the (b) (4) LAF that is located above the filling line. This deficiency does not ensure directional flow of the cleaning activities to prevent a potential cross contamination between uncleaned and cleaned zones. Furthermore, when reviewing the cleaning process for (b) (4) Injection USP …

    Contains “Grade A”Read the Form 483 →

  5. UBI Pharma Inc.Inspection ended Oct 14, 2025 · FEI 3004713402 · Observation 3

    … P366 Version 14 Intervention Procedure for Grade A and Grade A Air Supply Area During the Aseptic Filling Process and Operation Procedures for Grade B Area (Effective date 1/15 [illegible]) interrupted/blocked laminar air flow. C. Section 5.1.1.1.1 of your SOP No. P366 Version 14 requires that "before any aseptic operation, both hands to the operator from fingertip to elbows should be disinfected [illegible] disinfectant spray (6)(4)". At least …

    Contains “Grade A”Read the Form 483 →

  6. Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, followed, or including adequate validation of the sterilization process. Specifically, A. On 09/13/2025, I (EL) observed the aseptic assembly, set-up, and filling of (b)(4) (b)(4) Injection, U.S. Batch (b)(4) in Block (b)(4) vial filling line (b)(4) Room (b)(4) The following deficient aseptic practice was observed. …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  7. Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 2

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. During review of the environmental and personnel monitoring (EM and PM), the following was noted: A. From 01/2023 to date, a total of (4) batches were rejected due to EM or PM excursions. (4) of the rejections involved manufacturing Block (b)(4) PM excursions (Action limits for Grade A: (b)(4) Grade B: (4) cfu/plate or NMT (b)(4) cfu (b)(4) gown …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  8. Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 3

    There is a failure to thoroughly review any unexplained discrepancy, the failure of a batch or any of its components to meet any of its specifications, whether or not the batch has been already distributed. Specifically, A. FAR/25/001 was submitted on 01/17/2025 regarding bacteriological contamination observed in the aseptic process simulation (APS) Batch (b)(4) On 01/13/2025, APS Batch (b)(4) was conducted in Block (b)(4) Line (Room (b)(4) On …

    Contains “aseptic*”Read the Form 483 →

  9. Farmakeio Outsourcing LLCInspection ended Sep 5, 2025 · FEI 3014982757 · Observation 1

    … The [(D)(4)] intermediate product, which is (b)(4) and then processed into pellets, was visually inspected, packaged, [(6)(4)] sterilized, and distributed without this critical check. B. Your firm failed to adequately investigate received customer complaints. For example: 1. COMP-2025-0023 dated 6/20/2025 and COMP-2025-0018 dated 5/23/2025, documents received complaints for cracked pellets. Your firm's failed to adequately investigate the source …

    Contains “sterili*”Read the Form 483 →

  10. Farmakeio Outsourcing LLCInspection ended Sep 5, 2025 · FEI 3014982757 · Observation 2

    … Lot# 3131, including laboratory test chromatograms, unknown/unidentified peaks were found during sampling testing prior to and following [(b)(4)] - sterilization. Your firm's management reported they are aware of the unknown peaks and at the time of this inspection is working with a contract testing laboratory to identify and determine the pharmacological activity of the foreign peaks for the Testosterone/Triamcinolone Acetonide pellets. Your …

    Contains “sterili*”Read the Form 483 →

  11. Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 2

    Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, On 07/29/2025, black discoloration was observed on the interior HEPA bracket of the Aseptic Processing Workstation. This was located within Room 121-B and was being utilized in the sterility testing of the following: Ketamine HCL …

    Contains “aseptic*”Read the Form 483 →

  12. Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, The firm's procedure for collecting active viable air within the ISO-5 laminar airflow hood is not representative of the full duration of the sterile production process. The firm will only collect [illegible] of air within approximately [illegible] and that the production process within the laminar airflow hood lasts approximately …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  13. Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 4

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, The firm's procedure for testing (SOPDTN15300) is deficient in that [illegible] can be [illegible] and evaluated via [illegible] test for a total of [illegible] times before an investigation is conducted. For example, Event Report Form (ERF) #2025-067 was initiated on 04/16/2025 to document testing of …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  14. Tripak Pharmaceuticals Pty Ltd.Inspection ended Jul 25, 2025 · FEI 3008549263 · Observation 8

    Equipment and utensils shall be cleaned, maintained, and, as appropriate for the nature of the drug, sanitized and/or sterilized at appropriate intervals to prevent malfunctions or contamination that may alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements, Specifically, On 07/24/2025, during my walkthrough inspection at your manufacturing facility, I observed multiple …

    Contains “sterili*”Read the Form 483 →

  15. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. I visually observed contaminated / stained HEPA filter affecting ISO 5 hood in addition to hood [illegible] hoods, also have apparent contamination / stains. To date, no investigation has been opened regarding this apparent contamination. B. You lack a scientifically established …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  16. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 2

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, A. I observed apparent white colored residue and apparent brown or red colored stains on your work surfaces in your ISO 5 hood. The apparent white colored residue is also apparent throughout your ISO 5 environment affecting approximately all hoods. The design with the approximate of your working …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  17. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Personnel and environmental monitoring during and after your aseptic connection as well as throughout aseptic production is not scientifically performed. 1. The system by which you conduct personnel monitoring is not scientifically established. I observed personnel enter your ISO 5 environment with their hands and arms. You do not …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  18. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 6

    Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, particulate matter on 5/20/2025 in approximately [illegible] syringes which were a part of your media fill lot [illegible]. These syringes were previously inspected by your [illegible] on 5/07/2025 and 5/15/2025 and were not identified with particulate matter. B. You …

    Contains “media fill*”Read the Form 483 →

  19. Thrive Health and Wellness LLCInspection ended Apr 3, 2025 · FEI 3033176989 · Observation 1

    Lack of a certified ISO-5 classified area for sterile compounding Specifically, Your firm fills syringes intended for subcutaneous injection by withdrawing sterile solution from vials on a benchtop table, located in an unclassified room for the following products: • Semaglutide for injection • Tirzepatide for injection • Cyanocobalamin for injection • Lipoboost (B-complex) for injection • Sermorelin for injection The dosage of each product varies …

    Contains “ISO 5”Read the Form 483 →

  20. Thrive Health and Wellness LLCInspection ended Apr 3, 2025 · FEI 3033176989 · Observation 2

    Failures to conduct media fills that simulate aseptic production operations. Specifically, The operators involved in repackaging vials into syringe products intended to be sterile have never conducted media fills. For example, on 3/25/2025, it was observed that the operator produced Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL (5mL), Lot# 03065F, BUD: 7/6/2025; however, the operator has never conducted media fills. Your firm produced approximately …

    Contains “media fill*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.